From mboxrd@z Thu Jan 1 00:00:00 1970 From: Gary Funck Date: Mon, 17 Dec 2007 00:47:35 +0000 Subject: Re: [lm-sensors] w83627hf: invalid limits? Message-Id: <20071217004735.GB27938@intrepid.com> List-Id: References: <20071216231848.GA11241@intrepid.com> In-Reply-To: <20071216231848.GA11241@intrepid.com> MIME-Version: 1.0 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: 7bit To: lm-sensors@vger.kernel.org On 12/16/07 15:18:48, Gary Funck wrote: > > As you can see in some cases min is less than max, and in > other cases the indicated limit values are just plain wrong. > Any idea what is going on here, or how diagnose and fix the > problem? Follow-up: I tweaked sensors.conf and uncommented the limit settings. Everything okay now, except the clock battery probably needs to be replaced. :) What's the recommended method for monitoring the various sensors and/or sending an e-mail when a limit alarm has been hit? _______________________________________________ lm-sensors mailing list lm-sensors@lm-sensors.org http://lists.lm-sensors.org/mailman/listinfo/lm-sensors