From mboxrd@z Thu Jan 1 00:00:00 1970 From: Guenter Roeck Date: Fri, 11 Mar 2011 01:07:57 +0000 Subject: Re: [lm-sensors] RFC: nct6776f support in the w83627ehf and fan Message-Id: <20110311010757.GA30471@ericsson.com> List-Id: References: In-Reply-To: MIME-Version: 1.0 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: 7bit To: lm-sensors@vger.kernel.org On Thu, Mar 10, 2011 at 07:58:44PM -0500, Robert Kaiser wrote: > Guenter Roeck schrieb: > > On Thu, Mar 10, 2011 at 07:04:55PM -0500, Robert Kaiser wrote: > >> Guenter Roeck schrieb: > >>> Agreed. But you might be able to see the DIMM temperatures (if you have DDR3) > >>> by loading the "jc42" module. > >> > >> Hmm, doesn't seem to work, after loading jc43, I don't see anything new > >> appearing in sensors output. > >> > > jc42, not jc43. > > Right. I actually did a |modprobe jc42| and that didn't bring anything > new up in |sensors| output - but of course then I made a typo in here... > Too bad. So either you don't have DDR3 (unlikely), or Intel didn't wire it up to an i2c bus. > >>> So the temperatures you see as "SMBUSxxx" are really temperatures reported by the CPU. > >>> Just don't ask me why the CPU would report 0 degrees C ;). > >> > >> The i7-2600K is just an incredibly cool CPU, I guess. ;-) > >> > > Yes, and if you wire it up correctly you may be able to use it as refrigerator heat pump ;). > > Hmm, I guess I have to look up _those_ plans! ;-) > > > I copied a new version of the standalone driver to http://www.roeck-us.net/linux/drivers/w83627ehf/, > > in case you want to give it a try. > > Tested and works, thanks! > Thank you! Guenter _______________________________________________ lm-sensors mailing list lm-sensors@lm-sensors.org http://lists.lm-sensors.org/mailman/listinfo/lm-sensors