From mboxrd@z Thu Jan 1 00:00:00 1970 From: Guenter Roeck Date: Fri, 27 Jan 2012 22:41:24 +0000 Subject: Re: [lm-sensors] [w83627ehf] Not all fans are shown (#3) Message-Id: <20120127224124.GA32220@ericsson.com> List-Id: References: <20120127145130.GA29746@ericsson.com> In-Reply-To: <20120127145130.GA29746@ericsson.com> MIME-Version: 1.0 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: 7bit To: lm-sensors@vger.kernel.org Hi, On Fri, Jan 27, 2012 at 12:49:48PM -0500, CC wrote: [ ... ] > > > > I tested all three fan outputs. Another thing is weird: pwm1_mode has > > its meaning reversed (it's a 3-pin connector and the value 1 is DC > > mode, in contrast to pwm2 and the documentation). > > You lost me there. pwm1 supports both DC and PWM. pwm1_mode should return 0 for DC mode, 1 for pwm mode. The other pwm channels only support pwm mode on the NCT6776F, thus pwm2_mode and pwm3_mode should both return 1. Are you saying that reading pwm1_mode returns 1, and pwm2_mode and pwm3_mode both return 0 ? Thanks, Guenter _______________________________________________ lm-sensors mailing list lm-sensors@lm-sensors.org http://lists.lm-sensors.org/mailman/listinfo/lm-sensors