On Mon, Jun 11, 2012 at 12:28:57PM +0100, Lee Jones wrote: > On 11/06/12 11:36, Mark Brown wrote: > >Suppose you have two devices of the same type with an array of name > >based regulators, meaning the nodes with constraints have to have a > >particular name in order to be matched to the regulator. How would a > >consumer reference a node to specify a supply? > some-regulators { > compatible = "protect_me_from_similarly_named_regulators"; > > regulator_node_name_reg: regulator_node_name { > > }; > }; > [supply_name]-supply = <®ulator_node_name>; I'm not 100% sure you read what I wrote above or in all the previous mails about having two devices of the same type? The case where we have only one regulator of a given type obviously works otherwise people would have noticed, the problem starts when you have two of the same regulator device down. -------------- next part -------------- A non-text attachment was scrubbed... Name: signature.asc Type: application/pgp-signature Size: 836 bytes Desc: Digital signature URL: