From: Anton Vorontsov <anton.vorontsov@linaro.org>
To: Chanwoo Choi <cw00.choi@samsung.com>
Cc: myungjoo.ham@samsung.com, kyungmin.park@samsung.com,
linux-kernel@vger.kernel.org
Subject: Re: [PATCH v2 2/3] charger-manager: Fix bug when check dropped voltage after fullbatt event
Date: Sun, 16 Dec 2012 22:53:06 -0800 [thread overview]
Message-ID: <20121217064902.GA9027@lizard.gateway.2wire.net> (raw)
In-Reply-To: <1353570831-19439-1-git-send-email-cw00.choi@samsung.com>
On Thu, Nov 22, 2012 at 04:53:51PM +0900, Chanwoo Choi wrote:
> This patch check difference value between current voltage of battery
> and desc->fullbatt_uV whether positve or negative number. If difference
> value is negative number when current voltage of battery is larger than
> desc->fullbatt_uV, charger-manager return immediately because battery
> is fully charged.
>
> Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
> Signed-off-by: Myungjoo Ham <myungjoo.ham@samsung.com>
> Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
> ---
> drivers/power/charger-manager.c | 9 ++++++---
> 1 files changed, 6 insertions(+), 3 deletions(-)
>
> diff --git a/drivers/power/charger-manager.c b/drivers/power/charger-manager.c
> index ee039b9..17130c7 100644
> --- a/drivers/power/charger-manager.c
> +++ b/drivers/power/charger-manager.c
> @@ -468,7 +468,9 @@ static void fullbatt_vchk(struct work_struct *work)
> struct charger_manager *cm = container_of(dwork,
> struct charger_manager, fullbatt_vchk_work);
> struct charger_desc *desc = cm->desc;
> - int batt_uV, err, diff;
> + int batt_uV;
> + int err;
> + int diff;
I applied the patch, but dropped this part. This is an unrelated style
fix, and, if anything, it desires a separate patch (possibly 'fixing' the
whole file/driver).
Thanks!
> /* remove the appointment for fullbatt_vchk */
> cm->fullbatt_vchk_jiffies_at = 0;
> @@ -482,8 +484,9 @@ static void fullbatt_vchk(struct work_struct *work)
> return;
> }
>
> - diff = desc->fullbatt_uV;
> - diff -= batt_uV;
> + diff = desc->fullbatt_uV - batt_uV;
> + if (diff < 0)
> + return;
>
> dev_info(cm->dev, "VBATT dropped %duV after full-batt.\n", diff);
>
> --
> 1.7.0.4
next prev parent reply other threads:[~2012-12-17 6:56 UTC|newest]
Thread overview: 3+ messages / expand[flat|nested] mbox.gz Atom feed top
2012-11-22 7:53 [PATCH v2 2/3] charger-manager: Fix bug when check dropped voltage after fullbatt event Chanwoo Choi
2012-12-17 6:53 ` Anton Vorontsov [this message]
2012-12-17 7:15 ` Chanwoo Choi
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
Avoid top-posting and favor interleaved quoting:
https://en.wikipedia.org/wiki/Posting_style#Interleaved_style
* Reply using the --to, --cc, and --in-reply-to
switches of git-send-email(1):
git send-email \
--in-reply-to=20121217064902.GA9027@lizard.gateway.2wire.net \
--to=anton.vorontsov@linaro.org \
--cc=cw00.choi@samsung.com \
--cc=kyungmin.park@samsung.com \
--cc=linux-kernel@vger.kernel.org \
--cc=myungjoo.ham@samsung.com \
/path/to/YOUR_REPLY
https://kernel.org/pub/software/scm/git/docs/git-send-email.html
* If your mail client supports setting the In-Reply-To header
via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line
before the message body.
This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.