From: Baoquan He <bhe@redhat.com>
To: Joonsoo Kim <js1304@gmail.com>
Cc: Andrew Morton <akpm@linux-foundation.org>,
Linux Memory Management List <linux-mm@kvack.org>,
LKML <linux-kernel@vger.kernel.org>,
Johannes Weiner <hannes@cmpxchg.org>,
Michal Hocko <mhocko@kernel.org>,
Minchan Kim <minchan@kernel.org>,
Vlastimil Babka <vbabka@suse.cz>,
Mel Gorman <mgorman@techsingularity.net>,
kernel-team@lge.com, Ye Xiaolong <xiaolong.ye@intel.com>,
David Rientjes <rientjes@google.com>,
Joonsoo Kim <iamjoonsoo.kim@lge.com>
Subject: Re: [PATCH v3 1/2] mm/page_alloc: use ac->high_zoneidx for classzone_idx
Date: Mon, 23 Mar 2020 11:58:43 +0800 [thread overview]
Message-ID: <20200323035843.GH2987@MiWiFi-R3L-srv> (raw)
In-Reply-To: <CAAmzW4PVguD0jEEAt0ZUPqMykswuq2an21jRpP2ZuwRL6PYwCw@mail.gmail.com>
On 03/23/20 at 12:50pm, Joonsoo Kim wrote:
> Hello, Baoquan.
>
> 2020년 3월 20일 (금) 오후 7:30, Baoquan He <bhe@redhat.com>님이 작성:
> >
> >
> > On 03/20/20 at 05:32pm, js1304@gmail.com wrote:
> > > From: Joonsoo Kim <iamjoonsoo.kim@lge.com>
> > >
> > > Currently, we use the zone index of preferred_zone which represents
> > > the best matching zone for allocation, as classzone_idx. It has
> > > a problem on NUMA systems when the lowmem reserve protection exists
> > > for some zones on a node that do not exist on other nodes.
> > >
> > > In NUMA system, it can be possible that each node has different populated
> > > zones. For example, node 0 could have DMA/DMA32/NORMAL/MOVABLE zone and
> > > node 1 could have only NORMAL zone. In this setup, allocation request
> > > initiated on node 0 and the one on node 1 would have different
> > > classzone_idx, 3 and 2, respectively, since their preferred_zones are
> > > different. If the allocation is local, there is no problem. However,
> > > if it is handled by the remote node due to memory shortage, the problem
> > > would happen.
> >
> > Hi Joonsoo,
> >
> > Not sure if adding one sentence into above paragraph would be make it
> > easier to understand. Assume you are only talking about the high_zoneidx
> > is MOVABLE_ZONE with calculation of gfp_zone(gfp_mask), since any other
> > case doesn't have this problem. Please correct me if I am wrong.
>
> You're right. This example is for the allocation request with
> gfp_zone(gfp_mask),
> MOVABLE_ZONE.
>
> > In NUMA system, it can be possible that each node has different populated
> > zones. For example, node 0 could have DMA/DMA32/NORMAL/MOVABLE zone and
> > node 1 could have only NORMAL zone. In this setup, if we get high_zoneidx
> > as 3 (namely MOVABLE zone), with gfp_zone(gfp_mask), allocation request
> > initiated on node 0 and the one on node 1 would have different
> > classzone_idx, 3 and 2, respectively, since their preferred_zones are
> > different. If the allocation is local, there is no problem. However,
> > if it is handled by the remote node due to memory shortage, the problem
> > would happen.
>
> I'm okay with your change but I try again to be better. Please check the
> following rewritten commit message and please let me know if it is better
> than before.
Yeah, this new one looks very detailed, I believe anyone interested can
get what's going on. Thanks for doing this.
>
> Thanks.
>
> ------------------------>8-------------------------------
> From 3842d99d54c02c25cc6f6077fd0e97acabc10917 Mon Sep 17 00:00:00 2001
> From: Joonsoo Kim <iamjoonsoo.kim@lge.com>
> Date: Fri, 4 May 2018 09:55:21 +0900
> Subject: [PATCH] mm/page_alloc: use ac->high_zoneidx for classzone_idx
>
> Currently, we use classzone_idx to calculate lowmem reserve proetection
> for an allocation request. This classzone_idx causes a problem
> on NUMA systems when the lowmem reserve protection exists for some zones
> on a node that do not exist on other nodes.
>
> Before further explanation, I should first clarify how to compute
> the classzone_idx and the high_zoneidx.
>
> - ac->high_zoneidx is computed via the arcane gfp_zone(gfp_mask) and
> represents the index of the highest zone the allocation can use
> - classzone_idx was supposed to be the index of the highest zone on
> the local node that the allocation can use, that is actually available
> in the system
>
> Think about following example. Node 0 has 4 populated zone,
> DMA/DMA32/NORMAL/MOVABLE. Node 1 has 1 populated zone, NORMAL. Some zones,
> such as MOVABLE, doesn't exist on node 1 and this makes following
> difference.
>
> Assume that there is an allocation request whose gfp_zone(gfp_mask) is
> the zone, MOVABLE. Then, it's high_zoneidx is 3. If this allocation is
> initiated on node 0, it's classzone_idx is 3 since actually
> available/usable zone on local (node 0) is MOVABLE. If this allocation
> is initiated on node 1, it's classzone_idx is 2 since actually
> available/usable zone on local (node 1) is NORMAL.
>
> You can see that classzone_idx of the allocation request are different
> according to their starting node, even if their high_zoneidx is the same.
>
> Think more about these two allocation requests. If they are processed
> on local, there is no problem. However, if allocation is initiated
> on node 1 are processed on remote, in this example, at the NORMAL zone
> on node 0, due to memory shortage, problem occurs. Their different
> classzone_idx leads to different lowmem reserve and then different
> min watermark. See the following example.
>
> root@ubuntu:/sys/devices/system/memory# cat /proc/zoneinfo
> Node 0, zone DMA
> per-node stats
> ...
> pages free 3965
> min 5
> low 8
> high 11
> spanned 4095
> present 3998
> managed 3977
> protection: (0, 2961, 4928, 5440)
> ...
> Node 0, zone DMA32
> pages free 757955
> min 1129
> low 1887
> high 2645
> spanned 1044480
> present 782303
> managed 758116
> protection: (0, 0, 1967, 2479)
> ...
> Node 0, zone Normal
> pages free 459806
> min 750
> low 1253
> high 1756
> spanned 524288
> present 524288
> managed 503620
> protection: (0, 0, 0, 4096)
> ...
> Node 0, zone Movable
> pages free 130759
> min 195
> low 326
> high 457
> spanned 1966079
> present 131072
> managed 131072
> protection: (0, 0, 0, 0)
> ...
> Node 1, zone DMA
> pages free 0
> min 0
> low 0
> high 0
> spanned 0
> present 0
> managed 0
> protection: (0, 0, 1006, 1006)
> Node 1, zone DMA32
> pages free 0
> min 0
> low 0
> high 0
> spanned 0
> present 0
> managed 0
> protection: (0, 0, 1006, 1006)
> Node 1, zone Normal
> per-node stats
> ...
> pages free 233277
> min 383
> low 640
> high 897
> spanned 262144
> present 262144
> managed 257744
> protection: (0, 0, 0, 0)
> ...
> Node 1, zone Movable
> pages free 0
> min 0
> low 0
> high 0
> spanned 262144
> present 0
> managed 0
> protection: (0, 0, 0, 0)
>
> - static min watermark for the NORMAL zone on node 0 is 750.
> - lowmem reserve for the request with classzone idx 3 at the NORMAL
> on node 0 is 4096.
> - lowmem reserve for the request with classzone idx 2 at the NORMAL
> on node 0 is 0.
>
> So, overall min watermark is:
> allocation initiated on node 0 (classzone_idx 3): 750 + 4096 = 4846
> allocation initiated on node 1 (classzone_idx 2): 750 + 0 = 750
>
> allocation initiated on node 1 will have some precedence than allocation
> initiated on node 0 because min watermark of the former allocation is
> lower than the other. So, allocation initiated on node 1 could succeed
> on node 0 when allocation initiated on node 0 could not, and, this could
> cause too many numa_miss allocation. Then, performance could be
> downgraded.
>
> Recently, there was a regression report about this problem on CMA patches
> since CMA memory are placed in ZONE_MOVABLE by those patches. I checked
> that problem is disappeared with this fix that uses high_zoneidx
> for classzone_idx.
>
> http://lkml.kernel.org/r/20180102063528.GG30397@yexl-desktop
>
> Using high_zoneidx for classzone_idx is more consistent way than previous
> approach because system's memory layout doesn't affect anything to it.
> With this patch, both classzone_idx on above example will be 3 so will
> have the same min watermark.
>
> allocation initiated on node 0: 750 + 4096 = 4846
> allocation initiated on node 1: 750 + 4096 = 4846
>
> One could wonder if there is a side effect that allocation initiated on
> node 1 will use higher bar when allocation is handled on local since
> classzone_idx could be higher than before. It will not happen because
> the zone without managed page doesn't contributes lowmem_reserve at all.
>
> Reported-by: Ye Xiaolong <xiaolong.ye@intel.com>
> Tested-by: Ye Xiaolong <xiaolong.ye@intel.com>
> Acked-by: Vlastimil Babka <vbabka@suse.cz>
> Signed-off-by: Joonsoo Kim <iamjoonsoo.kim@lge.com>
> ---
> mm/internal.h | 2 +-
> 1 file changed, 1 insertion(+), 1 deletion(-)
>
> diff --git a/mm/internal.h b/mm/internal.h
> index c39c895..aebaa33 100644
> --- a/mm/internal.h
> +++ b/mm/internal.h
> @@ -119,7 +119,7 @@ struct alloc_context {
> bool spread_dirty_pages;
> };
>
> -#define ac_classzone_idx(ac) zonelist_zone_idx(ac->preferred_zoneref)
> +#define ac_classzone_idx(ac) (ac->high_zoneidx)
>
> /*
> * Locate the struct page for both the matching buddy in our
> --
> 2.7.4
>
next prev parent reply other threads:[~2020-03-23 3:59 UTC|newest]
Thread overview: 7+ messages / expand[flat|nested] mbox.gz Atom feed top
2020-03-20 8:32 [PATCH v3 0/2] integrate classzone_idx and high_zoneidx js1304
2020-03-20 8:32 ` [PATCH v3 1/2] mm/page_alloc: use ac->high_zoneidx for classzone_idx js1304
2020-03-20 10:30 ` Baoquan He
2020-03-23 3:50 ` Joonsoo Kim
2020-03-23 3:58 ` Baoquan He [this message]
2020-03-23 4:18 ` Joonsoo Kim
2020-03-20 8:32 ` [PATCH v3 2/2] mm/page_alloc: integrate classzone_idx and high_zoneidx js1304
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
Avoid top-posting and favor interleaved quoting:
https://en.wikipedia.org/wiki/Posting_style#Interleaved_style
* Reply using the --to, --cc, and --in-reply-to
switches of git-send-email(1):
git send-email \
--in-reply-to=20200323035843.GH2987@MiWiFi-R3L-srv \
--to=bhe@redhat.com \
--cc=akpm@linux-foundation.org \
--cc=hannes@cmpxchg.org \
--cc=iamjoonsoo.kim@lge.com \
--cc=js1304@gmail.com \
--cc=kernel-team@lge.com \
--cc=linux-kernel@vger.kernel.org \
--cc=linux-mm@kvack.org \
--cc=mgorman@techsingularity.net \
--cc=mhocko@kernel.org \
--cc=minchan@kernel.org \
--cc=rientjes@google.com \
--cc=vbabka@suse.cz \
--cc=xiaolong.ye@intel.com \
/path/to/YOUR_REPLY
https://kernel.org/pub/software/scm/git/docs/git-send-email.html
* If your mail client supports setting the In-Reply-To header
via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line
before the message body.
This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.