From mboxrd@z Thu Jan 1 00:00:00 1970 From: Peter Enderborg Subject: Rawmidi bug or missed feature? Date: Thu, 28 Feb 2002 23:56:35 +0100 Message-ID: <3C7EB5A2.335E82C4@ufh.se> Mime-Version: 1.0 Content-Type: text/plain; charset=us-ascii Content-Transfer-Encoding: 7bit Errors-To: alsa-devel-admin@lists.sourceforge.net List-Help: List-Post: List-Subscribe: , List-Unsubscribe: , List-Archive: To: "alsa-devel@lists.sourceforge.net" List-Id: alsa-devel@alsa-project.org I have a program that read's from a raw midi device. In midi there are some simple compression. It is assumed that if the data flow is correct, and the data should be interpreted as paramaters to previus command if it's not a new command. But when I open a raw midi stream I can get in to the stream without having the "previus" command. Is there any way to do a query or reset the stream so I can get that command? If it's only one midi channel sending the same type of command it will never get in to sync! _______________________________________________ Alsa-devel mailing list Alsa-devel@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/alsa-devel