From mboxrd@z Thu Jan 1 00:00:00 1970 Return-Path: Received: from mail.tiscali.be (unknown [62.235.14.106]) by dsl2.external.hp.com (Postfix) with ESMTP id CD8344829 for ; Tue, 24 Sep 2002 06:54:56 -0600 (MDT) Date: Tue, 24 Sep 2002 14:54:53 +0200 Message-ID: <3D8F0114000004FF@ocpmta2.be.tiscali.com> In-Reply-To: From: jsoe0708@tiscali.be Subject: RE: [parisc-linux] Help wanted: XF86Config (B2600) To: joachim.weller@philips.com, parisc-linux@lists.parisc-linux.org MIME-Version: 1.0 Content-Type: text/plain; charset="US-ASCII" Sender: parisc-linux-admin@lists.parisc-linux.org Errors-To: parisc-linux-admin@lists.parisc-linux.org List-Help: List-Post: List-Subscribe: , List-Id: parisc-linux developers list List-Unsubscribe: , List-Archive: Hey Joachim, Have first a look with dmesg. For my b2k a get unfortunately: ... STI device: HPA4982A stifb: Unsupported gfx card id 0x35acda16 ... Joel >-- Original Message -- >From: joachim.weller@philips.com >To: parisc-linux@lists.parisc-linux.org >Subject: [parisc-linux] Help wanted: XF86Config (B2600) >Date: Tue, 24 Sep 2002 14:40:33 +0200 > > >Hi, > >since yesterday, I have up and running a B2600 with Debian woody 3.0, >but I can't setup X11 Configuration for the built in PCI Grafic card, >using framebuffer driver. > >The error message in /etc/XFree86.0.log (XFree86 Version 4.1.0.1) >says: >(EE) No devices detected. > >although I have put in /etc/X11/XF86Config: > >Section "Device" > BoardName "hp-3D" > Identifier "Device[0]" > BusID "1:3:0" > Driver "fbdev" > Option "UseFBDev" "true" > Screen 0 >EndSection > >The BusID was determined by "cat /proc/pci" : > Bus 1, device 3, function 0: > 3D controller: PCI device 103c:108b (Hewlett-Packard Company) (rev 5). > IRQ 258. > Master Capable. Latency=255. > Prefetchable 64 bit memory at 0xfffffffffb000000 >[0xfffffffffbffffff]. > Non-prefetchable 64 bit memory at 0xfffffffffa000000 >[0xfffffffffaffffff]. > >If anybody has the same grafic card running, I would very much appreciate >to get a working XF86Config or any tips to resolve that problem. > >Regards, > Joachim > >Joachim Weller > >Philips Medizin Systeme Boeblingen GmbH >Cardiac and Monitoring Systems (CMS) /New Product Engineering >Phone: {+49|0}-7031-463-1891 >Fax: {+49|0}-7031-463-2112 >________________________________________________________________________________ >Gesch?ftsf?hrer: Dr. Werner Haas, David Russell, Wolfgang Strenzl >(Sprecher) >Sitz der Gesellschaft: B?blingen Registergericht B?blingen Reg.-Nr. HRB >5187 >Hewlett-Packard Str. 2, D 71034 Boeblingen -GERMANY-