From mboxrd@z Thu Jan 1 00:00:00 1970 From: Christophe Varoqui Subject: Re: multipath and StorageWorks HSG80 Date: Thu, 20 Apr 2006 22:53:00 +0200 Message-ID: <4447F4AC.5040904@free.fr> References: <20060420194321.GE29759@ingress.sbb.uvm.edu> <4447E8BF.1060205@bzed.de> <20060420204739.GB32417@ingress.sbb.uvm.edu> Reply-To: device-mapper development Mime-Version: 1.0 Content-Type: text/plain; charset=ISO-8859-1; format=flowed Content-Transfer-Encoding: quoted-printable Return-path: In-Reply-To: <20060420204739.GB32417@ingress.sbb.uvm.edu> List-Unsubscribe: , List-Archive: List-Post: List-Help: List-Subscribe: , Sender: dm-devel-bounces@redhat.com Errors-To: dm-devel-bounces@redhat.com To: device-mapper development List-Id: dm-devel.ids Steve Feehan a =E9crit : > On Thu, Apr 20, 2006 at 10:02:07PM +0200, Bernd Zeimetz wrote: > =20 >> Steve Feehan wrote: >> =20 >>> Hello. I'm trying to figure out multipath on a StorageWorks HSG80 >>> contoller. I'm using Ubuntu "Dapper" with the following software >>> =20 >>> =20 >> there was a thread about the HSG80s few days ago. >> http://www.redhat.com/archives/dm-devel/2006-April/msg00025.html >> probably that answers all your questions. >> =20 > > Yes, I saw that. The particular problem that I saw there > was the misreporting of unit size. The Ubuntu init script > takes care of this and all of my units report the same=20 > size. > > =20 That's certainly where the IO errors are triggered at bootup. Can you send the code snippet ? Regards, cvaroqui