From mboxrd@z Thu Jan 1 00:00:00 1970 From: Moebius Date: Wed, 21 Nov 2007 18:49:13 +0000 Subject: [lm-sensors] how to choose the right sensor with an asus M2NPV-VM Message-Id: <47447DA9.3090701@free.fr> List-Id: MIME-Version: 1.0 Content-Type: text/plain; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable To: lm-sensors@vger.kernel.org Bonjour, I've recently bought this config : athlon64 x2 4400+ and the asus=20 M2NPV-VM board. There is 4 fan plugs on the board, but only two are connected, the cpu's=20 one and the power one (with just 2 wires) Sensors-detect give me this output : Driver `smartbatt' (should be inserted): Detects correctly: * Bus `NVIDIA i2c adapter ' Busdriver `UNKNOWN', I2C address 0x0b Chip `Smart Battery' (confidence: 5) Driver `it87' (should be inserted): Detects correctly: * ISA bus, address 0x290 Chip `ITE IT8716F Super IO Sensors' (confidence: 9) Driver `k8temp' (should be inserted): Detects correctly: * Chip `AMD K8 thermal sensors' (confidence: 9) So I insert the two modules needed (it87 and k8temp) I'm following an ubuntu tuto here (in french... ) : http://doc.ubuntu-fr.org/materiel/sensors Well, then I try pwmconfig and it become very difficult : First, jit's not too bad : Found the following devices: hwmon0/device is k8temp hwmon1/device is it8716 Found the following PWM controls: hwmon1/device/pwm1 hwmon1/device/pwm2 hwmon1/device/pwm3 Found the following fan sensors: hwmon1/device/fan1_input current speed: 3082 RPM hwmon1/device/fan2_input current speed: 0 ... skipping! hwmon1/device/fan3_input current speed: 1646 RPM But when I try the command sensors to see which are the cpu sensor, the=20 mb sensor ... I get something a bit confusing : k8temp-pci-00c3 Adapter: PCI adapter Core0 Temp: -6=B0C Core0 Temp: -11=B0C Core1 Temp: +5=B0C Core1 Temp: -13=B0C it8716-isa-0290 Adapter: ISA adapter VCore: +1.02 V (min =3D +0.00 V, max =3D +4.08 V) VDDR: +3.31 V (min =3D +0.00 V, max =3D +4.08 V) +3.3V: +0.00 V (min =3D +0.00 V, max =3D +4.08 V) ALARM +5V: +4.84 V (min =3D +0.00 V, max =3D +6.85 V) +12V: +11.46 V (min =3D +0.00 V, max =3D +16.32 V) in5: +0.00 V (min =3D +0.00 V, max =3D +4.08 V) ALARM in6: +0.00 V (min =3D +0.00 V, max =3D +4.08 V) ALARM 5VSB: +4.73 V (min =3D +0.00 V, max =3D +6.85 V) VBat: +2.90 V fan1: 3096 RPM (min =3D 3245 RPM) ALARM fan2: 0 RPM (min =3D 3245 RPM) ALARM fan3: 1646 RPM (min =3D 0 RPM) temp1: +16=B0C (low =3D -1=B0C, high =3D +127=B0C) sensor =3D= diode temp2: +31=B0C (low =3D -1=B0C, high =3D +127=B0C) sensor =3D= =20 thermistor temp3: +25=B0C (low =3D -1=B0C, high =3D +127=B0C) sensor =3D= =20 thermistor vid: +0.000 V So I can't determine the sensor to assign the cpu fan, cause I can't see=20 which is the good cpu temperature. I've tried to search in the list but find nothing really simple, nor in=20 the sensors.conf.eg Well I'm a little confused, so if someone can help, it would be great cordialement, _______________________________________________ lm-sensors mailing list lm-sensors@lm-sensors.org http://lists.lm-sensors.org/mailman/listinfo/lm-sensors