From mboxrd@z Thu Jan 1 00:00:00 1970 From: George Joseph Date: Fri, 19 Feb 2010 21:28:00 +0000 Subject: Re: [lm-sensors] Status of Andigilog asc7621 driver submitted by Message-Id: <4B7F0260.9060807@fairview5.com> List-Id: References: <3f9a31f41001230952g6321c47bq9baf5dcfdfaf5b59@mail.gmail.com> In-Reply-To: <3f9a31f41001230952g6321c47bq9baf5dcfdfaf5b59@mail.gmail.com> MIME-Version: 1.0 Content-Type: text/plain; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable To: lm-sensors@vger.kernel.org On 2/19/2010 11:50 AM, Jaswinder Singh Rajput wrote: > Hello George, > > On Fri, Feb 19, 2010 at 11:24 PM, Jaswinder Singh Rajput > wrote: > =20 >> asc7621a-i2c-0-2e >> Adapter: SMBus I801 adapter at 2000 >> in0: +1.08 V (min =3D +0.00 V, max =3D +3.31 V) >> in1: +0.92 V (min =3D +0.00 V, max =3D +2.99 V) >> in2: +3.19 V (min =3D +0.00 V, max =3D +4.36 V) >> in3: +4.99 V (min =3D +0.00 V, max =3D +6.61 V) >> in4: +12.00 V (min =3D +0.00 V, max =3D +15.94 V) >> fan1: 947 RPM (min =3D 0 RPM) >> fan2: 2425 RPM (min =3D 0 RPM) >> fan3: 0 RPM (min =3D 0 RPM) >> fan4: 625 RPM (min =3D 0 RPM) >> temp1: -57.8=B0C (low =3D -127.0=B0C, high =3D +0.0=B0C) >> (crit =3D -17.0=B0C) >> temp2: +35.5=B0C (low =3D -127.0=B0C, high =3D +127.0=B0C) >> (crit =3D +65.0=B0C) >> temp3: +42.0=B0C (low =3D -127.0=B0C, high =3D +127.0=B0C) >> (crit =3D +65.0=B0C) >> temp4: +52.0=B0C (low =3D -127.0=B0C, high =3D +127.0=B0C) >> (crit =3D +103.0=B0C) >> temp5: -58.0=B0C >> temp6: -84.5=B0C >> temp7: +96.2=B0C >> temp8: +118.5=B0C >> >> =20 > I did further investigations and noticed that in my case : temp1 > temp5 = and temp6, temp7 and temp8 are false readings which never > changes : > > temp1: -33.0=B0C (low =3D -127.0=B0C, high =3D +0.0=B0C) > (crit =3D -17.0=B0C) > temp2: +38.2=B0C (low =3D -127.0=B0C, high =3D +127.0=B0C) > (crit =3D +65.0=B0C) > temp3: +51.8=B0C (low =3D -127.0=B0C, high =3D +127.0=B0C) > (crit =3D +65.0=B0C) > temp4: +55.5=B0C (low =3D -127.0=B0C, high =3D +127.0=B0C) > (crit =3D +103.0=B0C) > temp5: -33.0=B0C > temp6: -84.5=B0C > temp7: +96.2=B0C > temp8: +118.5=B0C > > Can you give me some hint why temp6, temp7 and temp8 are showing wrong > value for Intel WX58BP with Core i7. > =20 The mapping of the temps is controlled by the motherboard design and the=20 BIOS. On most Intel motherboards... temp1 =3D PECI CPU temp. I.E. Degrees below thermal throttling. Similar = to what coretemp reports. temp2 =3D aSC7621 chip itself. I.E. Motherboard temp. temp3 =3D Sensor between the DIMM sockets. temp4 =3D CPU diode temp. temp5 =3D temp1 temp6, 7, 8 =3D Documented by Andigilog as additional PECI temps but not=20 documented by Intel. That's all the info I have. > Can you share your temp6, temp7 and temp8 readings. > =20 Pretty much same as yours. > Thanks, > -- > Jaswinder Singh. > =20 _______________________________________________ lm-sensors mailing list lm-sensors@lm-sensors.org http://lists.lm-sensors.org/mailman/listinfo/lm-sensors