All of lore.kernel.org
 help / color / mirror / Atom feed
From: Thomas Backlund <tmb@mageia.org>
To: Andreas Dilger <adilger@dilger.ca>
Cc: "linux-kernel@vger.kernel.org" <linux-kernel@vger.kernel.org>,
	"linux-ext4@vger.kernel.org" <linux-ext4@vger.kernel.org>
Subject: Re: INFO: task jbd2/dm-0-8:3993 blocked for more than 120 seconds
Date: Thu, 18 Aug 2011 00:08:53 +0300	[thread overview]
Message-ID: <4E4C2DE5.5020100@mageia.org> (raw)
In-Reply-To: <96850198-2253-40F7-B99C-62A6097278FA@dilger.ca>

Andreas Dilger skrev 17.8.2011 17:35:
> On 2011-08-17, at 7:31 AM, Thomas Backlund<tmb@mageia.org>  wrote:
>>
>> One of our buildnodes, a 8-core Supermicro X7DA8 system,
>> and a WDC WD1002FAEX-0 sata disk hits the "blocked for more than 120 seconds" several times, and ends up resetting the ata bus.
>>
>> The disk does not report any errors with smart, and we have the same model in a 24-core Supermicro X8DTN, and it does not show this problem.
>>
>> ata3.00: exception Emask 0x0 SAct 0x0 SErr 0x0 action 0x6 frozen
>> ata3.00: failed command: FLUSH CACHE EXT
>> ata3.00: cmd ea/00:00:00:00:00/00:00:00:00:00/a0 tag 0
>>          res 40/00:00:01:4f:c2/00:00:00:00:00/00 Emask 0x4 (timeout)
>> ata3.00: status: { DRDY }
>> ata3: soft resetting link
>> ata3.00: configured for UDMA/133
>> ata3.00: retrying FLUSH 0xea Emask 0x4
>> ata3: EH complete
>
> This is a problem with your disk hardware.
>

Are you sure?
I get nothing from smart, even after I had executed the long test...

# smartctl -a /dev/sda
smartctl 5.39.1 2010-01-28 r3054 [x86_64-mandriva-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     WDC WD1002FAEX-00Z3A0
Serial Number:    WD-WCATR3168879
Firmware Version: 05.01D05
User Capacity:    1,000,204,886,016 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Wed Aug 17 23:07:52 2011 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x85) Offline data collection activity
                                         was aborted by an interrupting 
command from host.
                                         Auto Offline Data Collection: 
Enabled.
Self-test execution status:      ( 241) Self-test routine in progress...
                                         10% of test remaining.
Total time to complete Offline
data collection:                 (17400) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                         Auto Offline data collection 
on/off support.
                                         Suspend Offline collection upon new
                                         command.
                                         Offline surface scan supported.
                                         Self-test supported.
                                         Conveyance Self-test supported.
                                         Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                         power-saving mode.
                                         Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                         General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        ( 201) minutes.
Conveyance self-test routine
recommended polling time:        (   5) minutes.
SCT capabilities:              (0x3037) SCT Status supported.
                                         SCT Feature Control supported.
                                         SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE 
UPDATED  WHEN_FAILED RAW_VALUE
   1 Raw_Read_Error_Rate     0x002f   200   200   051    Pre-fail 
Always       -       0
   3 Spin_Up_Time            0x0027   186   174   021    Pre-fail 
Always       -       3683
   4 Start_Stop_Count        0x0032   100   100   000    Old_age 
Always       -       15
   5 Reallocated_Sector_Ct   0x0033   200   200   140    Pre-fail 
Always       -       0
   7 Seek_Error_Rate         0x002e   200   200   000    Old_age 
Always       -       0
   9 Power_On_Hours          0x0032   091   091   000    Old_age 
Always       -       7113
  10 Spin_Retry_Count        0x0032   100   253   000    Old_age 
Always       -       0
  11 Calibration_Retry_Count 0x0032   100   253   000    Old_age 
Always       -       0
  12 Power_Cycle_Count       0x0032   100   100   000    Old_age 
Always       -       13
192 Power-Off_Retract_Count 0x0032   200   200   000    Old_age   Always 
       -       11
193 Load_Cycle_Count        0x0032   200   200   000    Old_age   Always 
       -       3
194 Temperature_Celsius     0x0022   115   108   000    Old_age   Always 
       -       32
196 Reallocated_Event_Count 0x0032   200   200   000    Old_age   Always 
       -       0
197 Current_Pending_Sector  0x0032   200   200   000    Old_age   Always 
       -       0
198 Offline_Uncorrectable   0x0030   200   200   000    Old_age 
Offline      -       0
199 UDMA_CRC_Error_Count    0x0032   200   200   000    Old_age   Always 
       -       0
200 Multi_Zone_Error_Rate   0x0008   200   200   000    Old_age 
Offline      -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining 
LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed without error       00%      7109 
      -
# 2  Extended offline    Completed without error       00%      7003 
      -
# 3  Extended offline    Completed without error       00%      6837 
      -
# 4  Extended offline    Completed without error       00%      6670 
      -
# 5  Extended offline    Completed without error       00%      6504 
      -
# 6  Extended offline    Completed without error       00%      6338 
      -
# 7  Extended offline    Completed without error       00%      6173 
      -
# 8  Extended offline    Completed without error       00%      6006 
      -
# 9  Extended offline    Completed without error       00%      5840 
      -
#10  Extended offline    Completed without error       00%      5674 
      -
#11  Extended offline    Completed without error       00%      5507 
      -
#12  Extended offline    Completed without error       00%      5340 
      -
#13  Extended offline    Completed without error       00%      5173 
      -
#14  Extended offline    Completed without error       00%      5007 
      -
#15  Extended offline    Completed without error       00%      4841 
      -
#16  Extended offline    Completed without error       00%      4675 
      -
#17  Extended offline    Completed without error       00%      4510 
      -
#18  Extended offline    Completed without error       00%      4344 
      -
#19  Extended offline    Completed without error       00%      4179 
      -
#20  Extended offline    Completed without error       00%      4012 
      -
#21  Extended offline    Completed without error       00%      3847 
      -

SMART Selective self-test log data structure revision number 1
  SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
     1        0        0  Not_testing
     2        0        0  Not_testing
     3        0        0  Not_testing
     4        0        0  Not_testing
     5        0        0  Not_testing
Selective self-test flags (0x0):
   After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

--
Thomas

  reply	other threads:[~2011-08-17 21:08 UTC|newest]

Thread overview: 4+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2011-08-17 13:31 INFO: task jbd2/dm-0-8:3993 blocked for more than 120 seconds Thomas Backlund
2011-08-17 14:35 ` Andreas Dilger
2011-08-17 21:08   ` Thomas Backlund [this message]
2011-08-17 23:48     ` Valdis.Kletnieks

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=4E4C2DE5.5020100@mageia.org \
    --to=tmb@mageia.org \
    --cc=adilger@dilger.ca \
    --cc=linux-ext4@vger.kernel.org \
    --cc=linux-kernel@vger.kernel.org \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.