Hi Denis, On 17/07/2012 04:09, Denis Kenzior wrote: > Hi Guillaume, > >>>> + /* >>>> + * According to the 3GPP specifications 23.038 >>>> + * section 6.2.1.1: >>>> + * In the case there is no character in the extension >>>> + * table, the character of the main default alphabet >>>> + * table or the character from the National Language >>>> + * Locking Shift Table should be displayed. >>>> + */ >>> >>> What version of 23.038 are you using? I cannot find such wording in R9 >>> or R10 specs. >> >> It is not the exact wording, I have just rephrased the comment. >> The exact wording it just below the GSM 7 bits default alphabet >> extension table in section 6.2.1.1 >> Generally, do you prefer having an exact extract of the 3GPP spec or >> just an explanation of what is happening? >> > > The preference is to quote the spec verbatim and enclose the quote in > "". You can quote fragments of a sentence, etc. > > You can paraphrase, but I prefer that we only do that to distill > something simple, e.g. maximum size of a structure/member. > Ok, I keep his in mind for the next patches. Kind regards, Guillaume