Hi Christopher, On 08/14/2012 09:16 AM, Christopher Vogl wrote: > Hi Denis, > > On 13/08/12 18:25, Denis Kenzior wrote: >> Hi Christopher, >> >> On 08/13/2012 08:23 AM, Christopher Vogl wrote: >>> Telit uses a 2 to enable indicator event reporting and >>> indicators in a +CIEV URC are identified by strings, not numbers. >> >> Yikes, can you include a sample AT trace? It sounds like something is >> going terribly wrong with CIEVs. > I included a debug output from the start of ofono until a valid ppp > connection. > I attached it at the end as it is quite long and would make this > unreadable. > Okay, it looks like the Telit firmware does indeed get this wrong. So feel free to add a Telit specific CIEV parser. Also, I'm seeing: Aug 8 11:36:04 mx31tt01 daemon.debug ofonod[496]: src/simfs.c:sim_fs_op_read_block() bufoff: 0, seekoff: 39, toread: 17 Aug 8 11:36:04 mx31tt01 daemon.err ofonod[496]: EFspn read successfully, but couldn't parse That looks a bit strange. Can you rm -rf /var/lib/ofono, rerun oFono and see if that message persists? Regards, -Denis