From mboxrd@z Thu Jan 1 00:00:00 1970 Message-ID: <50B73EA7.3070501@thrane.com> Date: Thu, 29 Nov 2012 11:53:27 +0100 From: Jesper Christensen MIME-Version: 1.0 Content-Type: text/plain; charset="ISO-8859-1" Content-Transfer-Encoding: 7bit Subject: [Xenomai] mutex and timers Reply-To: jesper.christensen@cobham.com List-Id: Discussions about the Xenomai project List-Unsubscribe: , List-Archive: List-Post: List-Help: List-Subscribe: , To: xenomai@xenomai.org Hello I was wondering if (and i have a feeling i already know the answer) it is a no-go to call rtdm_mutex_lock from a rtdm timer handler? I've just discovered that is what we do, and i have a feeling it is causing trouble (most of the time it seems to work however). -- /Jesper B. Christensen Development Engineer T +45 39 55 88 02 E jesper.christensen@cobham.com Thrane & Thrane A/S - Lundtoftegaardsvej 93D DK-2800 Kgs. Lyngby, Denmark - www.thrane.com