From mboxrd@z Thu Jan 1 00:00:00 1970 Content-Type: multipart/mixed; boundary="===============7035653680446198870==" MIME-Version: 1.0 From: Denis Kenzior Subject: Re: Unable to connect Huawei HiLink E303 Date: Thu, 06 Feb 2014 10:52:02 -0600 Message-ID: <52F3BDB2.6040106@gmail.com> In-Reply-To: List-Id: To: ofono@ofono.org --===============7035653680446198870== Content-Type: text/plain; charset="utf-8" MIME-Version: 1.0 Content-Transfer-Encoding: quoted-printable Hi Homam, > ofonod[17818]: drivers/atmodem/gprs-context.c:at_cgdata_cb() ok 0 > ofonod[17818]: Unable to enter data state > ofonod[17818]: src/gprs.c:pri_activate_callback() 0x2121c00 > ofonod[17818]: src/gprs.c:pri_activate_callback() Activating context fail= ed with error: Incorrect parameters > Can you enable AT command tracing by using: export OFONO_AT_DEBUG=3D1 the running ofonod and post that log. It looks like the either the APN setup is incorrect or the modem will = require us to use the legacy form of context activation instead of +CGDATA. Regards, -Denis --===============7035653680446198870==--