From: Kevin Hilman <khilman@baylibre.com>
To: Ulf Hansson <ulf.hansson@linaro.org>
Cc: "cristian.marussi@arm.com" <cristian.marussi@arm.com>,
"souvik.chakravarty@arm.com" <souvik.chakravarty@arm.com>,
Sudeep Holla <sudeep.holla@arm.com>,
"arm-scmi@vger.kernel.org" <arm-scmi@vger.kernel.org>,
Dhruva Gole <d-gole@ti.com>, Sebin Francis <sebin.francis@ti.com>
Subject: Re: mixing SCMI and PSCI power domain hierarchy
Date: Wed, 16 Apr 2025 09:34:21 -0700 [thread overview]
Message-ID: <7h7c3kcbg2.fsf@baylibre.com> (raw)
In-Reply-To: <CAPDyKFpuqk3jH91rkDDz_kejyJ5pFg5XH+=vdTA2aP8MJKUWrw@mail.gmail.com>
Ulf Hansson <ulf.hansson@linaro.org> writes:
> On Wed, 16 Apr 2025 at 02:22, Kevin Hilman <khilman@baylibre.com> wrote:
>>
>> Ulf Hansson <ulf.hansson@linaro.org> writes:
>>
>> > On Tue, 8 Apr 2025 at 01:31, Kevin Hilman <khilman@baylibre.com> wrote:
>> >>
>> >> Hello SCMI folks,
>> >>
>> >> I'm trying to figure out how to model a power-domain hierarchy when
>> >> there is a mixture of SCMI and PSCI domains.
>> >>
>> >> Let's say I have a top-level PD, managed by PSCI, but inside it it has
>> >> both a CPU cluster (with cluster & CPU PDs controlled by PSCI) as well
>> >> as some other sub-domains for leaf devices that are controlled by SCMI.
>> >> A simplified version looks something like this:
>> >>
>> >> SOC
>> >> |
>> >> |- TOP1_PD (PSCI)
>> >> |
>> >> |-- LEAF1_PD (SCMI)
>> >> |-- LEAF2_PD (SCMI)
>> >> |
>> >> \-- CLUSTER_PD (PSCI)
>> >> |
>> >> |-- CPU1_PD (PSCI)
>> >> \-- CPU2_PD (PSCI)
>> >>
>> >>
>> >> So the main question is: how do I describe the SCMI part of this today
>> >> in DT? Currently, I have something like this for the SCMI-controlled
>> >> PDs:
>> >>
>> >> scmi_pds: protocol@11 {
>> >> reg = <0x11>;
>> >> #power-domain-cells = <1>;
>> >> bootph-all;
>> >> };
>> >>
>> >> and the leaf devices under LEAF1_PD and LEAF2_PD would have
>> >> `power-domains = <&scmi_pds N>` properties, indicating their PD is
>> >> managed by SCMI. That part works fine. And I'm also able to model the
>> >> CPU PDs and CLUSTER_PD just fine, including using
>> >> domain-idle-states... (Hi Ulf ;)
>> >>
>> >> But... how do I describe the relationship of this hierarchy? In
>> >> particular, when the SCMI-controlled PDs are actually subdomains of a
>> >> top-level, non-SCMI PD. I tried adding `power-domains = <&TOP1_PD>`
>> >> inside the scmi_pds node, but that property seems to be ignored. So it
>> >> seems that currently it has not been considered to have SCMI PDs as
>> >> sub-domains of other PDs. Is that correct? Is this something anyone
>> >> else has considered adding?
>> >
>> > I haven't heard of this topology before, but I believe I can
>> > understand the need for it. Especially when using the PSCI OSI mode.
>> >
>> > In principle, if any of those LEAF1_PD/LEAF2_PD are being in use we
>> > must not allow the PSCI state to be selected that corresponds to the
>> > TOP1_PD. Right?
>>
>> Correct (mostly.) TOP_PD may potentially have multiple domain-idle
>> states, and if any LEAFx_PD are active, it could just mean that only the
>> retention state(s) of TOP_PD should be selected, not ones that involve
>> context loss.
>
> Okay, I get it.
>
> Do note that, the genpd and its governor doesn't support this today.
> Only when the child domain enters the deepest state, the parent domain
> can be powered-off (one of its states can be selected). Of course, I
> think it should be possible to extend genpd to support this.
Yes, I'm aware of the current limitations here. I hope to contribute
some support for this also.
>> > I can think of two ways forward, there may be others:
>> > 1) Put the leaf devices themselves in TOP1_PD *and* LEAF1_PD/LEAF2_PD.
>> > Thus these devices would have two power-domains. Whether this actually
>> > works for your case, I am not sure of, but I think it could be an
>> > option.
>>
>> Hmm, I don't follow. How/why would this help?
>>
>> And more importantly, does the current PM domain code support devices
>> that have multiple PM domains? I see there are examples in the binding
>> docs, but I have not seen that in practice anywhere yet. I did a quick
>> test by adding
>>
>> power-domains = <&scmi_pds N>, <&TOP_PD>;
>>
>> in one of the DT nodes, and at least according to
>> <debugfs>/pm_genpd_summary, not only does it disappear from the SCMI PD,
>> it also doesn't show up in TOP_PD. It seems it can be in one or the
>> other, but not both.
>
> Attaching a single PM domain is managed by bus-level code via
> dev_pm_domain_attach().
>
> If a device has multiple PM domains, the driver/bus for it needs to
> manage that specifically, typically by using
> dev_pm_domain_attach_list().
OK, I see. But in my quick experiment with this, I found that adding a
2nd domain to a devices power-domain property, it disappeared from the
first domain also. Any idea what is happening there?
> The idea in 1) was based upon that we
> could manage the two PM domains via a device_link that we would create
> when calling dev_pm_domain_attach_list(). Not sure if it would really
> that well, but possibly.
OK, I can have a look at this. But describing things in DT this way
( a leaf device listing 2 PDs ) doesn't seem like a correct description
of the hardware, and more of a workaround of Linux limitations.
>> > 2) Enable parents to be described in the "scmi_pds" node. To do that,
>> > we need to extend the DT bindings a bit, as we need the SCMI index
>> > that should correspond to the SCMI-child-power-domain. In other words
>> > "power-domains = <&TOP1_PD>" would not be sufficient.
>>
>> This is the direction that I was thinking makes the most sense, and
>> actually reflects real hardware.
>>
>> If you have any thoughts about what that binding change should look
>> like, maybe I can have a look at implementing it.
>
> Usually we describe parent domains by using the original power-domain
> DT binding, but this is limited to work for when the child-domain node
> has #power-domain-cells = <0>.
>
> We need to investigate if there are any other DT bindings we can get
> some influence from, perhaps clocks have something similar?
>
> Anyway, without further thinking my idea would be to add a new
> property ("power-domain-child-ids") where we can put a list of indexes
> for the child-domain that corresponds to each of the parents that we
> can list in "power-domains".
OK, I'll start researching some options here.
Thanks for the guidance,
Kevin
next prev parent reply other threads:[~2025-04-16 16:34 UTC|newest]
Thread overview: 12+ messages / expand[flat|nested] mbox.gz Atom feed top
2025-04-07 23:31 mixing SCMI and PSCI power domain hierarchy Kevin Hilman
2025-04-10 13:07 ` Ulf Hansson
2025-04-16 0:22 ` Kevin Hilman
2025-04-16 13:22 ` Ulf Hansson
2025-04-16 16:34 ` Kevin Hilman [this message]
2025-04-16 19:28 ` Kevin Hilman
2025-04-25 10:48 ` Ulf Hansson
2025-04-16 23:57 ` Kevin Hilman
2025-04-25 11:08 ` Ulf Hansson
2025-04-25 14:39 ` Kevin Hilman
2025-05-16 12:36 ` Ulf Hansson
2025-05-28 20:09 ` Kevin Hilman
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
Avoid top-posting and favor interleaved quoting:
https://en.wikipedia.org/wiki/Posting_style#Interleaved_style
* Reply using the --to, --cc, and --in-reply-to
switches of git-send-email(1):
git send-email \
--in-reply-to=7h7c3kcbg2.fsf@baylibre.com \
--to=khilman@baylibre.com \
--cc=arm-scmi@vger.kernel.org \
--cc=cristian.marussi@arm.com \
--cc=d-gole@ti.com \
--cc=sebin.francis@ti.com \
--cc=souvik.chakravarty@arm.com \
--cc=sudeep.holla@arm.com \
--cc=ulf.hansson@linaro.org \
/path/to/YOUR_REPLY
https://kernel.org/pub/software/scm/git/docs/git-send-email.html
* If your mail client supports setting the In-Reply-To header