On Thu, Feb 06, 2025 at 07:16:25PM -0800, Yidong Zhang wrote:
> 
> 
> On 2/6/25 18:19, Xu Yilun wrote:
> > Caution: This message originated from an External Source. Use proper caution when opening attachments, clicking links, or responding.
> > 
> > 
> > > > No need to detach a specific driver, remove all devices in the
> > > > fpga-region. I imagine this could also be a generic flow for all PCI/e
> > > > based FPGA cards.
> > > 
> > > I see your point. Is there an existing example in current fpga driver for
> > > PCI/e based cards?
> > 
> > No. The fpga-region re-enumeration arch is still WIP, so no existing
> > implementation.
> 
> Got you. I can also help to test or provide feedback.
> Actually, I had sent Nava my protype of using configfs for the non-OF
> driver. He should have the updated patch soon.
> 
> > 
> > > 
> > > We will need to talk to our management team and re-design our driver.
> > > I think we have 2 approaches:
> > > 1) Align with linux fpga, having one driver for both userPF and mgmtPF; or
> > 
> > Don't get you. Linux FPGA doesn't require one driver for both PFs.
> 
> I assume when you said "generic flow for removing all devices in
> fpga-region" means that there is a single driver which use the fpga-region
> callbacks to remove all devices and then re-progream the FPGA.
> 
> On AMD V70 hardware, the userPF has different deviceid than the mgmtPF.
> Thus, our current design is having 2 separate pcie drivers for each
> different deviceid.
> 
> Thus, in our current design, the fpga-region should be in the userPF driver
> which has callbacks to remove all devices. But in mgmtPF, it is more like a

A question, if the FPGA logic is cleared, does the userPF still exist on
PCIe bus?

> utility which only handles request from the userPF but it has the management
> privilege. Usually, cloud vendors require the mgmtPF deployed in their
> secured domain (can be a separate physical machine).

I though mgmtPF & userPF are just 2 functions on one PCIe card, they are not?
Then how the mgmtPF writes data to another physical machine and
influence the userPF?

Thanks,
Yilun

> 
> We can keep 2 drivers, one for userPF, one for mgmtPF. The userPF and mgmtPF
> communicate each other via the communication channel because they can be
> physically on different machine.
> 
> Are you looking for us to upstream both of them together?
> If yes, I still think that the fpga-region should be in the userPF driver.
> The mgmtPF driver is still a utility driver.
> 
> Please correct me if I am wrong.:)
> 
> > 
> > > 2) find a different location (maybe driver/misc) for the version-pci driver,
> > > because it is an utility driver, not need to be tied with fpga framework.
> > 
> > I'm not the misc maintainer, but I assume in-tree utility driver +
> > out-of-tree client driver is not generally welcomed.
> 
> Great info! Thanks! I will have to discuss this with my team too.
> 
> My understanding, so far based on your comments above, the drivers/fpga
> prefer to use fpga-region ops to handle FPGA re-program changes.
> 
> The current versal-pci driver is a utility driver.
> The fpga-region should be within the userPF driver.
> 
> We can try to make our userPF driver in-tree as well. But the current plan
> is to do it later.
> 
> If you prefer we do both of them together. I can talk to my team.
> 
> Thanks,
> David
> > 
> > Thanks,
> > Yilun
> > 
> > > 
> > > Please let me know you thoughts. Which way is acceptable by you.
> > > 
> > > Thanks,
> > > David
> > > > 
> > > > Thanks,
> > > > Yilun
> > > > 
> > > > > driver and allow the userPF driver re-enumerate all to match the new
> > > > > hardware.
> > > > > 
> > > > > I think my understanding is correct, it is doable.
> > > > > 
> > > > > As long as we can keep our userPF driver as separate driver, the code change
> > > > > won't be too big.
> > > > > 
> > > > > > 
> > > > > > Thanks,
> > > > > > Yilun

  reply	other threads:[~2025-02-07  4:41 UTC|newest]

Thread overview: 28+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2024-12-10 18:37 [PATCH V2 0/4] Add versal-pci driver Yidong Zhang
2024-12-10 18:37 ` [PATCH V2 1/4] drivers/fpga/amd: Add new driver amd versal-pci Yidong Zhang
2025-01-26  9:24   ` Xu Yilun
2025-01-26 19:50     ` Yidong Zhang
2025-01-26 10:12   ` Christophe JAILLET
2025-01-26 19:56     ` Yidong Zhang
2025-01-26 10:16   ` Christophe JAILLET
2025-01-26 10:32   ` Xu Yilun
2025-01-26 19:46     ` Yidong Zhang
2025-02-06  4:15       ` Xu Yilun
2025-02-06  4:31         ` Yidong Zhang
2025-02-07  2:19           ` Xu Yilun
2025-02-07  3:16             ` Yidong Zhang
2025-02-07  4:40               ` Xu Yilun [this message]
2025-02-10 11:33                 ` Yidong Zhang
2025-02-11  9:09                   ` Xu Yilun
2025-02-11 11:31                     ` Yidong Zhang
2025-03-01  8:20                       ` Xu Yilun
2025-03-01 19:03                         ` Yidong Zhang
2025-03-03  7:57                           ` Xu Yilun
2025-03-03 17:00                             ` Yidong Zhang
2024-12-10 18:37 ` [PATCH V2 2/4] drivers/fpga/amd: Add communication channel Yidong Zhang
2025-01-26 10:19   ` Christophe JAILLET
2025-01-26 19:57     ` Yidong Zhang
2024-12-10 18:37 ` [PATCH V2 3/4] drivers/fpga/amd: Add remote queue Yidong Zhang
2025-01-26 10:24   ` Christophe JAILLET
2024-12-10 18:37 ` [PATCH V2 4/4] drivers/fpga/amd: Add load xclbin and load firmware Yidong Zhang
2025-01-26  9:27 ` [PATCH V2 0/4] Add versal-pci driver Xu Yilun

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=Z6WO2Ktc9HoqdUSU@yilunxu-OptiPlex-7050 \
    --to=yilun.xu@linux.intel.com \
    --cc=Karthik.DMG@amd.com \
    --cc=hao.wu@intel.com \
    --cc=hayden.laccabue@amd.com \
    --cc=linux-fpga@vger.kernel.org \
    --cc=linux-kernel@vger.kernel.org \
    --cc=lizhi.hou@amd.com \
    --cc=mdf@kernel.org \
    --cc=nishads@amd.com \
    --cc=prapulk@amd.com \
    --cc=yidong.zhang@amd.com \
    --cc=yilun.xu@intel.com \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.