| Bug ID | 1626 |
|---|---|
| Summary | HPET timers do not work on the Osage customer reference platform |
| Product | DPDK |
| Version | unspecified |
| Hardware | All |
| OS | All |
| Status | UNCONFIRMED |
| Severity | normal |
| Priority | Normal |
| Component | eventdev |
| Assignee | dev@dpdk.org |
| Reporter | nandinipersad361@gmail.com |
| Target Milestone | --- |
HPET timers do not work on the Osage customer reference platform which includes an Intel® Xeon® processor 5500 series processor) using the released BIOS from Intel. Implication: On Osage boards, the implementation of the rte_delay_us() function must be changed to not use the HPET timer. Resolution/Workaround: This can be addressed by building the system with RTE_LIBEAL_USE_HPET unset or by using the --no-hpet EAL option. Affected Environment/Platform: The Osage customer reference platform. Other vendor platforms with Intel® Xeon® processor 5500 series processors should work correctly, provided the BIOS supports HPET. Driver/Module: lib/eal/include/rte_cycles.h