From mboxrd@z Thu Jan 1 00:00:00 1970 From: James Cloos Date: Wed, 27 Apr 2011 17:31:55 +0000 Subject: Re: [lm-sensors] f71889ed temp alarm polarity reversed. Message-Id: List-Id: References: In-Reply-To: MIME-Version: 1.0 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: 7bit To: lm-sensors@vger.kernel.org >>>>> "JD" = Jean Delvare writes: JD> Actually value 100000 and directory /sys/class/hwmon/hwmon#, JD> or /sys/class/hwmon/hwmon#/device. But it may be easier to add: JD> chip "f71889ed-*" JD> set temp1_max 90 JD> set temp1_crit 100 JD> set temp3_max 90 JD> set temp3_crit 100 JD> to /etc/sensors.d/f71889ed.conf and run "sensors -s". That alleviated the false alarms. Thanks. The fact that the temp sensor which is not connected was not in alarm, whereas the two which are were, led to my false diagnosis. Thanks both! -JimC -- James Cloos OpenPGP: 1024D/ED7DAEA6 _______________________________________________ lm-sensors mailing list lm-sensors@lm-sensors.org http://lists.lm-sensors.org/mailman/listinfo/lm-sensors