From mboxrd@z Thu Jan 1 00:00:00 1970 From: James Cloos Date: Sat, 23 Apr 2011 22:39:47 +0000 Subject: [lm-sensors] f71889ed temp alarm polarity reversed. Message-Id: List-Id: MIME-Version: 1.0 Content-Type: text/plain; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable To: lm-sensors@vger.kernel.org As of Linus' v2.6.39-rc4-89-g2f666bc I still get: fan1: 871 RPM fan2: 0 RPM ALARM fan3: 0 RPM ALARM temp1: +35.0=B0C (high =3D +255.0=B0C, hyst =3D +251.0=B0C) ALARM = (CRIT) (crit =3D +255.0=B0C, hyst =3D +251.0=B0C) sensor = =3D transistor temp2: FAULT (high =3D +255.0=B0C, hyst =3D +251.0=B0C) (crit =3D +255.0=B0C, hyst =3D +251.0=B0C) sensor = =3D transistor temp3: +38.0=B0C (high =3D +255.0=B0C, hyst =3D +253.0=B0C) ALARM = (CRIT) (crit =3D +255.0=B0C, hyst =3D +253.0=B0C) sensor = =3D transistor The polarity for the fan alarms is correct, but it is reversed for the temp alarms. -JimC --=20 James Cloos OpenPGP: 1024D/ED7DAEA6 _______________________________________________ lm-sensors mailing list lm-sensors@lm-sensors.org http://lists.lm-sensors.org/mailman/listinfo/lm-sensors