* [Cluster-devel] [PATCH][fence-agents] fence_eaton_snmp: add support for Eaton Switched ePDU
@ 2011-07-04 18:59 Arnaud Quette
  2011-07-05  7:38 ` Fabio M. Di Nitto
  2011-07-08  8:39 ` Marek Grac
  0 siblings, 2 replies; 5+ messages in thread
From: Arnaud Quette @ 2011-07-04 18:59 UTC (permalink / raw)
  To: cluster-devel.redhat.com

Hi,

you will find attached  a patch that adds support for Eaton Switched ePDU to
fence_eaton_snmp.
please consider applying it.

cheers,
Arnaud
-- 
Linux / Unix Expert R&D - Eaton - http://powerquality.eaton.com
Network UPS Tools (NUT) Project Leader - http://www.networkupstools.org/
Debian Developer - http://www.debian.org
Free Software Developer - http://arnaud.quette.free.fr/
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://listman.redhat.com/archives/cluster-devel/attachments/20110704/0b3cbd01/attachment.htm>
-------------- next part --------------
diff --git a/fence/agents/eaton_snmp/fence_eaton_snmp.py b/fence/agents/eaton_snmp/fence_eaton_snmp.py
index 81d9810..e24cc13 100644
--- a/fence/agents/eaton_snmp/fence_eaton_snmp.py
+++ b/fence/agents/eaton_snmp/fence_eaton_snmp.py
@@ -1,7 +1,8 @@
 #!/usr/bin/python
 
 # The Following agent has been tested on:
-# - Eaton ePDU managed - SNMP v1
+# - Eaton ePDU Managed - SNMP v1
+# - Eaton ePDU Switched - SNMP v1
 
 import sys, re, pexpect
 sys.path.append("@FENCEAGENTSLIBDIR@")
@@ -19,7 +20,7 @@ BUILD_DATE=""
 OID_SYS_OBJECT_ID='.1.3.6.1.2.1.1.2.0'
 
 ### GLOBAL VARIABLES ###
-# Device - see EatonManagedePDU
+# Device - see EatonManagedePDU, EatonSwitchedePDU
 device=None
 
 # Port ID
@@ -27,7 +28,11 @@ port_id=None
 # Switch ID
 switch_id=None
 
+# Did we issue a set before get (to adjust OID with Switched ePDU)
+after_set=False
+
 # Classes describing Device params
+# Managed ePDU
 class EatonManagedePDU:
 	status_oid=      '.1.3.6.1.4.1.534.6.6.6.1.2.2.1.3.%d'
 	control_oid=     '.1.3.6.1.4.1.534.6.6.6.1.2.2.1.3.%d'
@@ -35,18 +40,34 @@ class EatonManagedePDU:
 	ident_str="Eaton Managed ePDU"
 	state_off=0
 	state_on=1
-	state_cycling=2
+	state_cycling=2	# FIXME: not usable with fence-agents
 	turn_off=0
 	turn_on=1
-	turn_cycle=2
-	# FIXME: what's this?
+	turn_cycle=2	# FIXME: not usable with fence-agents
+	has_switches=False
+
+# Switched ePDU (Pulizzi 2)
+# NOTE: sysOID reports "20677.1", while data are actually at "20677.2"
+class EatonSwitchedePDU:
+	status_oid=      '.1.3.6.1.4.1.20677.2.6.3.%d.0'
+	control_oid=     '.1.3.6.1.4.1.20677.2.6.2.%d.0'
+	outlet_table_oid='.1.3.6.1.4.1.20677.2.6.3'
+	ident_str="Eaton Switched ePDU"
+	state_off=2
+	state_on=1
+	state_cycling=0 # Note: this status doesn't exist on this device
+	turn_off=2
+	turn_on=1
+	turn_cycle=3	# FIXME: not usable with fence-agents
 	has_switches=False
 
 ### FUNCTIONS ###
 def eaton_set_device(conn,options):
 	global device
 
-	agents_dir={'.1.3.6.1.4.1.534.6.6.6':EatonManagedePDU}
+	agents_dir={'.1.3.6.1.4.1.534.6.6.6':EatonManagedePDU,
+				'.1.3.6.1.4.1.20677.1':EatonSwitchedePDU,
+				'.1.3.6.1.4.1.20677.2':EatonSwitchedePDU }
 
 	# First resolve type of Eaton
 	eaton_type=conn.walk(OID_SYS_OBJECT_ID)
@@ -64,6 +85,10 @@ def eaton_resolv_port_id(conn,options):
 	if (device==None):
 		eaton_set_device(conn,options)
 
+	# Restore the increment, that was removed in main for ePDU Managed
+	if (device.ident_str == "Eaton Switched ePDU"):
+		options["-n"] = str(int(options["-n"]) + 1)
+
 	# Now we resolv port_id/switch_id
 	if ((options["-n"].isdigit()) and ((not device.has_switches) or (options["-s"].isdigit()))):
 		port_id=int(options["-n"])
@@ -80,28 +105,53 @@ def eaton_resolv_port_id(conn,options):
 					port_id=int(t[len(t)-1])
 					switch_id=int(t[len(t)-3])
 				else:
-					port_id=int(t[len(t)-1])
+					if (device.ident_str == "Eaton Switched ePDU"):
+						port_id=int(t[len(t)-3])
+					else:
+						port_id=int(t[len(t)-1])
 
 	if (port_id==None):
+		# Restore index offset, to provide a valid error output on Managed ePDU
+		if (device.ident_str != "Eaton Switched ePDU"):
+			options["-n"] = str(int(options["-n"]) + 1)
 		fail_usage("Can't find port with name %s!"%(options["-n"]))
 
 def get_power_status(conn,options):
-	global port_id,switch_id,device
+	global port_id,switch_id,device,after_set
 
 	if (port_id==None):
 		eaton_resolv_port_id(conn,options)
 
+	# Ajust OID for Switched ePDU when the get is after a set
+	if ((after_set == True) and (device.ident_str == "Eaton Switched ePDU")):
+		port_id-=1
+		after_set=False
+
 	oid=((device.has_switches) and device.status_oid%(switch_id,port_id) or device.status_oid%(port_id))
 
-	(oid,status)=conn.get(oid)
-	return (status==str(device.state_on) and "on" or "off")
+	try:
+		(oid,status)=conn.get(oid)
+		if (status==str(device.state_on)):
+			return "on"
+		elif (status==str(device.state_off)):
+			return "off"
+		else:
+			return None
+	except:
+		return None
 
 def set_power_status(conn, options):
-	global port_id,switch_id,device
+	global port_id,switch_id,device,after_set
+
+	after_set = True
 
 	if (port_id==None):
 		eaton_resolv_port_id(conn,options)
 
+	# Controls start at #2 on Switched ePDU, since #1 is the global command
+	if (device.ident_str == "Eaton Switched ePDU"):
+		port_id=int(port_id)+1
+
 	oid=((device.has_switches) and device.control_oid%(switch_id,port_id) or device.control_oid%(port_id))
 
 	conn.set(oid,(options["-o"]=="on" and device.turn_on or device.turn_off))
@@ -110,6 +160,7 @@ def set_power_status(conn, options):
 def get_outlets_status(conn, options):
 	global device
 
+	outletCount = 0
 	result={}
 
 	if (device==None):
@@ -118,19 +169,31 @@ def get_outlets_status(conn, options):
 	res_ports=conn.walk(device.outlet_table_oid,30)
 
 	for x in res_ports:
+		outletCount+=1
+		status=x[1]
 		t=x[0].split('.')
 
 		# Plug indexing start from zero, so we substract '1' from the
 		# user's given plug number
-		port_num=str(int(((device.has_switches) and "%s:%s"%(t[len(t)-3],t[len(t)-1]) or "%s"%(t[len(t)-1]))) + 1)
-
-                # Plug indexing start from zero, so we add '1'
-                # for the user's exposed plug number
-                port_name=str(int(x[1].strip('"')) + 1)
-                port_status=""
-                result[port_num]=(port_name,port_status)
-
-        return result
+		if (device.ident_str == "Eaton Managed ePDU"):
+			port_num=str(int(((device.has_switches) and "%s:%s"%(t[len(t)-3],t[len(t)-1]) or "%s"%(t[len(t)-1]))) + 1)
+
+			# Plug indexing start from zero, so we add '1'
+			# for the user's exposed plug number
+			port_name=str(int(x[1].strip('"')) + 1)
+			port_status=""
+			result[port_num]=(port_name,port_status)
+		else:
+			# Switched ePDU do not propose an outletCount OID!
+			# Invalid status (ie value == '0'), retrieved via the walk,
+			# means the outlet is absent
+			port_num=str(outletCount)
+			port_name=str(outletCount)
+			port_status=""
+			if (status != '0'):
+				result[port_num]=(port_name,port_status)
+
+	return result
 
 # Define new options
 def eaton_snmp_define_defaults():
@@ -154,7 +217,7 @@ def main():
 
 	options=check_input(device_opt,process_input(device_opt))
 
-        ## Support for -n [switch]:[plug] notation that was used before
+	## Support for -n [switch]:[plug] notation that was used before
 	if ((options.has_key("-n")) and (-1 != options["-n"].find(":"))):
 		(switch, plug) = options["-n"].split(":", 1)
 		if ((switch.isdigit()) and (plug.isdigit())):
@@ -164,8 +227,9 @@ def main():
 	if (not (options.has_key("-s"))):
 		options["-s"]="1"
 
-	# Plug indexing start from zero, so we substract '1' from the
-	# user's given plug number
+	# Plug indexing start from zero on ePDU Managed, so we substract '1' from
+	# the user's given plug number.
+	# For Switched ePDU, we will add this back again later.
 	if ((options.has_key("-n")) and (options["-n"].isdigit())):
 		options["-n"] = str(int(options["-n"]) - 1)
 

^ permalink raw reply related	[flat|nested] 5+ messages in thread

* [Cluster-devel] [PATCH][fence-agents] fence_eaton_snmp: add support for Eaton Switched ePDU
  2011-07-04 18:59 [Cluster-devel] [PATCH][fence-agents] fence_eaton_snmp: add support for Eaton Switched ePDU Arnaud Quette
@ 2011-07-05  7:38 ` Fabio M. Di Nitto
  2011-07-05  8:15   ` Arnaud Quette
  2011-07-08  8:39 ` Marek Grac
  1 sibling, 1 reply; 5+ messages in thread
From: Fabio M. Di Nitto @ 2011-07-05  7:38 UTC (permalink / raw)
  To: cluster-devel.redhat.com

On 7/4/2011 8:59 PM, Arnaud Quette wrote:
> Hi,
> 
> you will find attached  a patch that adds support for Eaton Switched
> ePDU to fence_eaton_snmp.
> please consider applying it.

Applied, thanks.

I tested the changes against the managed ePDU I have here and I don?t
see regressions.

Fabio



^ permalink raw reply	[flat|nested] 5+ messages in thread

* [Cluster-devel] [PATCH][fence-agents] fence_eaton_snmp: add support for Eaton Switched ePDU
  2011-07-05  7:38 ` Fabio M. Di Nitto
@ 2011-07-05  8:15   ` Arnaud Quette
  0 siblings, 0 replies; 5+ messages in thread
From: Arnaud Quette @ 2011-07-05  8:15 UTC (permalink / raw)
  To: cluster-devel.redhat.com

Hi Fabio,

2011/7/5 Fabio M. Di Nitto <fdinitto@redhat.com>

> On 7/4/2011 8:59 PM, Arnaud Quette wrote:
> > Hi,
> >
> > you will find attached  a patch that adds support for Eaton Switched
> > ePDU to fence_eaton_snmp.
> > please consider applying it.
>
> Applied, thanks.
>

excellent, thanks.


> I tested the changes against the managed ePDU I have here and I don?t
> see regressions.
>

so did I. thanks for counter checking.

cheers,
Arnaud
-- 
Linux / Unix Expert R&D - Eaton - http://powerquality.eaton.com
Network UPS Tools (NUT) Project Leader - http://www.networkupstools.org/
Debian Developer - http://www.debian.org
Free Software Developer - http://arnaud.quette.free.fr/
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://listman.redhat.com/archives/cluster-devel/attachments/20110705/a1eaec8c/attachment.htm>

^ permalink raw reply	[flat|nested] 5+ messages in thread

* [Cluster-devel] [PATCH][fence-agents] fence_eaton_snmp: add support for Eaton Switched ePDU
  2011-07-04 18:59 [Cluster-devel] [PATCH][fence-agents] fence_eaton_snmp: add support for Eaton Switched ePDU Arnaud Quette
  2011-07-05  7:38 ` Fabio M. Di Nitto
@ 2011-07-08  8:39 ` Marek Grac
  2011-07-10 20:10   ` Arnaud Quette
  1 sibling, 1 reply; 5+ messages in thread
From: Marek Grac @ 2011-07-08  8:39 UTC (permalink / raw)
  To: cluster-devel.redhat.com

Hi Arnaud,

On 07/04/2011 08:59 PM, Arnaud Quette wrote:
> Hi,
>
> you will find attached  a patch that adds support for Eaton Switched 
> ePDU to fence_eaton_snmp.
> please consider applying it.

What do you think about replacing magic numbers (+1, -1, -3) with some 
constants with names?

m,



^ permalink raw reply	[flat|nested] 5+ messages in thread

* [Cluster-devel] [PATCH][fence-agents] fence_eaton_snmp: add support for Eaton Switched ePDU
  2011-07-08  8:39 ` Marek Grac
@ 2011-07-10 20:10   ` Arnaud Quette
  0 siblings, 0 replies; 5+ messages in thread
From: Arnaud Quette @ 2011-07-10 20:10 UTC (permalink / raw)
  To: cluster-devel.redhat.com

2011/7/8 Marek Grac <mgrac@redhat.com>

> Hi Arnaud,


Hi Marek,


> On 07/04/2011 08:59 PM, Arnaud Quette wrote:
>
>> Hi,
>>
>> you will find attached  a patch that adds support for Eaton Switched ePDU
>> to fence_eaton_snmp.
>> please consider applying it.
>>
>
> What do you think about replacing magic numbers (+1, -1, -3) with some
> constants with names?


something cleaner is scheduled with the new PDU type I'll be adding soon
(not yet investigated).
I've added the present (2nd) too urgently for doing something clean... but
it was still worth to release.

cheers,
Arnaud
-- 
Linux / Unix Expert R&D - Eaton - http://powerquality.eaton.com
Network UPS Tools (NUT) Project Leader - http://www.networkupstools.org/
Debian Developer - http://www.debian.org
Free Software Developer - http://arnaud.quette.free.fr/
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://listman.redhat.com/archives/cluster-devel/attachments/20110710/62226cb6/attachment.htm>

^ permalink raw reply	[flat|nested] 5+ messages in thread

end of thread, other threads:[~2011-07-10 20:10 UTC | newest]

Thread overview: 5+ messages (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2011-07-04 18:59 [Cluster-devel] [PATCH][fence-agents] fence_eaton_snmp: add support for Eaton Switched ePDU Arnaud Quette
2011-07-05  7:38 ` Fabio M. Di Nitto
2011-07-05  8:15   ` Arnaud Quette
2011-07-08  8:39 ` Marek Grac
2011-07-10 20:10   ` Arnaud Quette

This is a public inbox, see mirroring instructions