dev.dpdk.org archive mirror
 help / color / mirror / Atom feed
* [PATCH v1] net/mlx5: fix indirect meter index leak
@ 2025-11-05 12:54 Rongwei Liu
  2025-11-06 14:15 ` Raslan Darawsheh
  0 siblings, 1 reply; 2+ messages in thread
From: Rongwei Liu @ 2025-11-05 12:54 UTC (permalink / raw)
  To: dev, matan, viacheslavo, orika, suanmingm, thomas
  Cc: akozyrev, stable, Dariusz Sosnowski, Bing Zhao

When destroying the meter_mark indirect action, PMD
didn't recycle the ipool resources.

Fixes: 48fbb0e93d06 ("net/mlx5: support flow meter mark indirect action with HWS")
Cc: akozyrev@nvidia.com
Cc: stable@dpdk.org

Signed-off-by: Rongwei Liu <rongweil@nvidia.com>
Acked-by: Dariusz Sosnowski <dsosnowski@nvidia.com>
---
 drivers/net/mlx5/mlx5_flow_hw.c | 17 ++++++++++-------
 1 file changed, 10 insertions(+), 7 deletions(-)

diff --git a/drivers/net/mlx5/mlx5_flow_hw.c b/drivers/net/mlx5/mlx5_flow_hw.c
index ff68483a40..22503f49d5 100644
--- a/drivers/net/mlx5/mlx5_flow_hw.c
+++ b/drivers/net/mlx5/mlx5_flow_hw.c
@@ -13011,13 +13011,16 @@ flow_hw_action_handle_destroy(struct rte_eth_dev *dev, uint32_t queue,
 			break;
 		}
 		/* Wait for ASO object completion. */
-		if (queue == MLX5_HW_INV_QUEUE &&
-		    mlx5_aso_mtr_wait(priv, aso_mtr, true)) {
-			ret = -EINVAL;
-			rte_flow_error_set(error, EINVAL,
-				RTE_FLOW_ERROR_TYPE_UNSPECIFIED,
-				NULL, "Unable to wait for ASO meter CQE");
-			break;
+		if (queue == MLX5_HW_INV_QUEUE) {
+			if (mlx5_aso_mtr_wait(priv, aso_mtr, true)) {
+				ret = -EINVAL;
+				rte_flow_error_set(error, EINVAL,
+					RTE_FLOW_ERROR_TYPE_UNSPECIFIED,
+					NULL, "Unable to wait for ASO meter CQE");
+			}
+			mlx5_ipool_free(pool->idx_pool, idx);
+			if (ret < 0)
+				break;
 		}
 		aso = true;
 		break;
-- 
2.27.0


^ permalink raw reply related	[flat|nested] 2+ messages in thread

* Re: [PATCH v1] net/mlx5: fix indirect meter index leak
  2025-11-05 12:54 [PATCH v1] net/mlx5: fix indirect meter index leak Rongwei Liu
@ 2025-11-06 14:15 ` Raslan Darawsheh
  0 siblings, 0 replies; 2+ messages in thread
From: Raslan Darawsheh @ 2025-11-06 14:15 UTC (permalink / raw)
  To: Rongwei Liu, dev, matan, viacheslavo, orika, suanmingm, thomas
  Cc: akozyrev, stable, Dariusz Sosnowski, Bing Zhao

Hi,


On 05/11/2025 2:54 PM, Rongwei Liu wrote:
> When destroying the meter_mark indirect action, PMD
> didn't recycle the ipool resources.
> 
> Fixes: 48fbb0e93d06 ("net/mlx5: support flow meter mark indirect action with HWS")
> Cc: akozyrev@nvidia.com
> Cc: stable@dpdk.org
> 
> Signed-off-by: Rongwei Liu <rongweil@nvidia.com>
> Acked-by: Dariusz Sosnowski <dsosnowski@nvidia.com>

Patch applied to next-net-mlx,

Kindest regards
Raslan Darawsheh


^ permalink raw reply	[flat|nested] 2+ messages in thread

end of thread, other threads:[~2025-11-06 14:16 UTC | newest]

Thread overview: 2+ messages (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2025-11-05 12:54 [PATCH v1] net/mlx5: fix indirect meter index leak Rongwei Liu
2025-11-06 14:15 ` Raslan Darawsheh

This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).