public inbox for intel-gfx@lists.freedesktop.org
 help / color / mirror / Atom feed
From: Patchwork <patchwork@emeril.freedesktop.org>
To: Navare@emeril.freedesktop.org, Manasi D <manasi.d.navare@intel.com>
Cc: intel-gfx@lists.freedesktop.org
Subject: ✗ Fi.CI.BAT: failure for Link Training failure handling by sending Hotplug Uevent (rev3)
Date: Thu, 08 Dec 2016 19:53:34 -0000	[thread overview]
Message-ID: <20161208195334.7904.21294@emeril.freedesktop.org> (raw)
In-Reply-To: <1480984058-552-1-git-send-email-manasi.d.navare@intel.com>

== Series Details ==

Series: Link Training failure handling by sending Hotplug Uevent (rev3)
URL   : https://patchwork.freedesktop.org/series/16399/
State : failure

== Summary ==

Series 16399v3 Link Training failure handling by sending Hotplug Uevent
https://patchwork.freedesktop.org/api/1.0/series/16399/revisions/3/mbox/

Test drv_module_reload:
        Subgroup basic-reload:
                pass       -> DMESG-WARN (fi-ilk-650)
        Subgroup basic-reload-final:
                pass       -> DMESG-WARN (fi-ilk-650)
        Subgroup basic-reload-inject:
                pass       -> INCOMPLETE (fi-bxt-t5700)
                dmesg-warn -> INCOMPLETE (fi-skl-6700k)
                pass       -> DMESG-WARN (fi-ilk-650)
Test gem_busy:
        Subgroup basic-hang-default:
                pass       -> DMESG-WARN (fi-ilk-650)
Test gem_exec_suspend:
        Subgroup basic-s3:
                pass       -> DMESG-WARN (fi-ilk-650)
        Subgroup basic-s4-devices:
                pass       -> DMESG-WARN (fi-ilk-650)
Test gem_flink_basic:
        Subgroup bad-open:
                pass       -> DMESG-WARN (fi-ilk-650)
        Subgroup basic:
                pass       -> DMESG-WARN (fi-ilk-650)
Test kms_addfb_basic:
        Subgroup addfb25-x-tiled:
                pass       -> DMESG-WARN (fi-ilk-650)
        Subgroup addfb25-x-tiled-mismatch:
                pass       -> DMESG-WARN (fi-ilk-650)
        Subgroup addfb25-yf-tiled:
                pass       -> DMESG-WARN (fi-ilk-650)
Test kms_busy:
        Subgroup basic-flip-default-a:
                pass       -> DMESG-WARN (fi-ilk-650)
        Subgroup basic-flip-default-b:
                pass       -> DMESG-WARN (fi-ilk-650)
Test kms_cursor_legacy:
        Subgroup basic-busy-flip-before-cursor-legacy:
                pass       -> DMESG-WARN (fi-ilk-650)
        Subgroup basic-busy-flip-before-cursor-varying-size:
                pass       -> DMESG-WARN (fi-ilk-650)
        Subgroup basic-flip-after-cursor-legacy:
                pass       -> DMESG-WARN (fi-ilk-650)
        Subgroup basic-flip-after-cursor-varying-size:
                pass       -> DMESG-WARN (fi-ilk-650)
        Subgroup basic-flip-before-cursor-legacy:
                pass       -> DMESG-WARN (fi-ilk-650)
        Subgroup basic-flip-before-cursor-varying-size:
                pass       -> DMESG-WARN (fi-ilk-650)
Test kms_flip:
        Subgroup basic-flip-vs-dpms:
                pass       -> DMESG-WARN (fi-ilk-650)
        Subgroup basic-flip-vs-modeset:
                pass       -> DMESG-WARN (fi-ilk-650)
        Subgroup basic-flip-vs-wf_vblank:
                pass       -> DMESG-WARN (fi-ilk-650)
        Subgroup basic-plain-flip:
                pass       -> DMESG-WARN (fi-ilk-650)
Test kms_pipe_crc_basic:
        Subgroup bad-nb-words-1:
                pass       -> DMESG-WARN (fi-ilk-650)
        Subgroup bad-nb-words-3:
                pass       -> DMESG-WARN (fi-ilk-650)
        Subgroup bad-pipe:
                pass       -> DMESG-WARN (fi-ilk-650)
        Subgroup bad-source:
                pass       -> DMESG-WARN (fi-ilk-650)
        Subgroup hang-read-crc-pipe-a:
                pass       -> DMESG-WARN (fi-ilk-650)
        Subgroup hang-read-crc-pipe-b:
                pass       -> DMESG-WARN (fi-ilk-650)
        Subgroup nonblocking-crc-pipe-a:
                pass       -> DMESG-WARN (fi-ilk-650)
        Subgroup nonblocking-crc-pipe-a-frame-sequence:
                pass       -> DMESG-WARN (fi-ilk-650)
        Subgroup nonblocking-crc-pipe-b:
                pass       -> DMESG-WARN (fi-ilk-650)
        Subgroup nonblocking-crc-pipe-b-frame-sequence:
                pass       -> DMESG-WARN (fi-ilk-650)
        Subgroup read-crc-pipe-a:
                pass       -> DMESG-WARN (fi-ilk-650)
        Subgroup read-crc-pipe-a-frame-sequence:
                pass       -> DMESG-WARN (fi-ilk-650)
        Subgroup read-crc-pipe-b:
                pass       -> DMESG-WARN (fi-ilk-650)
        Subgroup read-crc-pipe-b-frame-sequence:
                pass       -> DMESG-WARN (fi-ilk-650)
        Subgroup suspend-read-crc-pipe-a:
                pass       -> DMESG-WARN (fi-ilk-650)
        Subgroup suspend-read-crc-pipe-b:
                pass       -> DMESG-WARN (fi-ilk-650)
Test kms_setmode:
        Subgroup basic-clone-single-crtc:
                pass       -> DMESG-WARN (fi-ilk-650)

fi-bdw-5557u     total:247  pass:233  dwarn:0   dfail:0   fail:0   skip:14 
fi-bsw-n3050     total:247  pass:208  dwarn:0   dfail:0   fail:0   skip:39 
fi-bxt-t5700     total:7    pass:6    dwarn:0   dfail:0   fail:0   skip:0  
fi-byt-j1900     total:247  pass:220  dwarn:0   dfail:0   fail:0   skip:27 
WARNING: Long output truncated

1117c18cdbf8312b696b79ae1846e1ebe99b8501 drm-tip: 2016y-12m-08d-16h-04m-38s UTC integration manifest
dea1aa7 drm/i915: Implement Link Rate fallback on Link training failure
b92832c drm/i915: Find fallback link rate/lane count
01576aa drm/i915: Compute sink's max lane count/link BW at Hotplug
6b5cb5c drm: Add a new connector atomic property for link status

== Logs ==

For more details see: https://intel-gfx-ci.01.org/CI/Patchwork_3243/
_______________________________________________
Intel-gfx mailing list
Intel-gfx@lists.freedesktop.org
https://lists.freedesktop.org/mailman/listinfo/intel-gfx

  parent reply	other threads:[~2016-12-08 19:53 UTC|newest]

Thread overview: 33+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2016-12-06  0:27 [PATCH 0/4] Link Training failure handling by sending Hotplug Uevent Manasi Navare
2016-12-06  0:27 ` [PATCH 1/4] drm: Add a new connector atomic property for link status Manasi Navare
2016-12-06  7:23   ` [Intel-gfx] " Daniel Vetter
2016-12-06 15:56     ` Manasi Navare
2016-12-06 16:07   ` [PATCH v4 " Manasi Navare
2016-12-08 15:05     ` Jani Nikula
2016-12-08 15:28       ` [Intel-gfx] " Daniel Vetter
2016-12-08 19:04     ` [PATCH v5 " Manasi Navare
2016-12-08 19:36       ` Sean Paul
2016-12-08 19:48         ` Manasi Navare
2016-12-08 19:47       ` [PATCH v6 " Manasi Navare
2016-12-06  0:27 ` [PATCH 2/4] drm/i915: Compute sink's max lane count/link BW at Hotplug Manasi Navare
2016-12-08 18:15   ` Manasi Navare
2016-12-08 21:23   ` Jani Nikula
2016-12-08 21:39     ` Manasi Navare
2016-12-08 21:48     ` Manasi Navare
2016-12-13 14:28       ` Jani Nikula
2016-12-06  0:27 ` [PATCH 3/4] drm/i915: Find fallback link rate/lane count Manasi Navare
2016-12-08 18:19   ` Manasi Navare
2016-12-08 21:46   ` Jani Nikula
2016-12-08 22:05     ` Manasi Navare
2016-12-09  3:05   ` [PATCH v7 " Manasi Navare
2016-12-09  9:54     ` Jani Nikula
2016-12-13 14:36       ` Jani Nikula
2016-12-06  0:27 ` [PATCH 4/4] drm/i915: Implement Link Rate fallback on Link training failure Manasi Navare
2016-12-08 18:23   ` Manasi Navare
2016-12-08 21:51   ` Jani Nikula
2016-12-08 22:09     ` Manasi Navare
2016-12-06  0:53 ` ✗ Fi.CI.BAT: failure for Link Training failure handling by sending Hotplug Uevent Patchwork
2016-12-06 16:53 ` ✗ Fi.CI.BAT: failure for Link Training failure handling by sending Hotplug Uevent (rev2) Patchwork
2016-12-08 19:53 ` Patchwork [this message]
2016-12-08 20:23 ` ✗ Fi.CI.BAT: failure for Link Training failure handling by sending Hotplug Uevent (rev4) Patchwork
2016-12-09  4:23 ` ✗ Fi.CI.BAT: failure for Link Training failure handling by sending Hotplug Uevent (rev5) Patchwork

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=20161208195334.7904.21294@emeril.freedesktop.org \
    --to=patchwork@emeril.freedesktop.org \
    --cc=Navare@emeril.freedesktop.org \
    --cc=intel-gfx@lists.freedesktop.org \
    --cc=manasi.d.navare@intel.com \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox