From mboxrd@z Thu Jan 1 00:00:00 1970 From: dan.carpenter@oracle.com Date: Wed, 8 Jul 2020 14:47:51 +0300 Subject: [Intel-wired-lan] [bug report] igc: Add initial LTR support Message-ID: <20200708114751.GA11509@mwanda> MIME-Version: 1.0 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: 7bit To: intel-wired-lan@osuosl.org List-ID: Hello Sasha Neftin, The patch 707abf069548: "igc: Add initial LTR support" from Jun 2, 2020, leads to the following static checker warning: drivers/net/ethernet/intel/igc/igc_mac.c:424 igc_check_for_copper_link() error: uninitialized symbol 'link'. drivers/net/ethernet/intel/igc/igc_mac.c 363 s32 igc_check_for_copper_link(struct igc_hw *hw) 364 { 365 struct igc_mac_info *mac = &hw->mac; 366 s32 ret_val; 367 bool link; ^^^^^^^^^ 368 369 /* We only want to go out to the PHY registers to see if Auto-Neg 370 * has completed and/or if our link status has changed. The 371 * get_link_status flag is set upon receiving a Link Status 372 * Change or Rx Sequence Error interrupt. 373 */ 374 if (!mac->get_link_status) { 375 ret_val = 0; 376 goto out; ^^^^^^^^ 377 } 378 379 /* First we want to see if the MII Status Register reports 380 * link. If so, then we want to get the current speed/duplex 381 * of the PHY. 382 */ 383 ret_val = igc_phy_has_link(hw, 1, 0, &link); 384 if (ret_val) 385 goto out; 386 387 if (!link) 388 goto out; /* No link detected */ 389 390 mac->get_link_status = false; 391 392 /* Check if there was DownShift, must be checked 393 * immediately after link-up 394 */ 395 igc_check_downshift(hw); 396 397 /* If we are forcing speed/duplex, then we simply return since 398 * we have already determined whether we have link or not. 399 */ 400 if (!mac->autoneg) { 401 ret_val = -IGC_ERR_CONFIG; 402 goto out; 403 } 404 405 /* Auto-Neg is enabled. Auto Speed Detection takes care 406 * of MAC speed/duplex configuration. So we only need to 407 * configure Collision Distance in the MAC. 408 */ 409 igc_config_collision_dist(hw); 410 411 /* Configure Flow Control now that Auto-Neg has completed. 412 * First, we need to restore the desired flow control 413 * settings because we may have had to re-autoneg with a 414 * different link partner. 415 */ 416 ret_val = igc_config_fc_after_link_up(hw); 417 if (ret_val) 418 hw_dbg("Error configuring flow control\n"); 419 420 out: 421 /* Now that we are aware of our link settings, we can set the LTR 422 * thresholds. 423 */ 424 ret_val = igc_set_ltr_i225(hw, link); ^^^^ Uninitialized. 425 426 return ret_val; 427 } regards, dan carpenter