From mboxrd@z Thu Jan 1 00:00:00 1970 From: jbrunet@baylibre.com (Jerome Brunet) Date: Sat, 21 Jul 2018 22:46:50 +0200 Subject: [PATCH 3/3] clk: meson: clk-pll: drop hard-coded rates from pll tables In-Reply-To: References: <20180717095617.12240-1-jbrunet@baylibre.com> <20180717095617.12240-4-jbrunet@baylibre.com> Message-ID: <1532206010.26720.84.camel@baylibre.com> To: linus-amlogic@lists.infradead.org List-Id: linus-amlogic.lists.infradead.org On Sat, 2018-07-21 at 22:16 +0200, Martin Blumenstingl wrote: > > We could even add ranges instead of table when we know the PLL supports a well-known continuous dividers range. > > I had a look at the sys_pll settings on Meson8b, here's what > Meson8/Meson8b/Meson8m2 support for sys_pll: > - 50..74 > - 76 > - 78 > - 80 > - 82 > - 84 > - 86 > - 88 > - 90 > - 92 > - 94 > - 96 > - 98 Are those values with the same predivider (n) value ? I suspect the ability of the DCO to lock might depends on its input rate and an m range So if n change, it might possible that the m range will be different. ... at least, that's my guess :) > > (I'm providing this info because it may help finding a decision > whether ranges are good or not. I have no preference)