From mboxrd@z Thu Jan 1 00:00:00 1970 From: lee.jones@linaro.org (Lee Jones) Date: Wed, 8 May 2013 14:29:04 +0100 Subject: [PATCH 4/9] mfd: db8500-prcmu: Supply the pdata_size attribute for db8500-thermal In-Reply-To: <1368019749-19455-1-git-send-email-lee.jones@linaro.org> References: <1368019749-19455-1-git-send-email-lee.jones@linaro.org> Message-ID: <1368019749-19455-5-git-send-email-lee.jones@linaro.org> To: linux-arm-kernel@lists.infradead.org List-Id: linux-arm-kernel.lists.infradead.org The MFD subsystem requires drivers to state the size of any platform data passed, or it will fail to assign it to the device. This will culminate in a NULL platform_data attribute and normally a failure to probe() or a kernel Oops. Cc: Samuel Ortiz Signed-off-by: Lee Jones --- drivers/mfd/db8500-prcmu.c | 1 + 1 file changed, 1 insertion(+) diff --git a/drivers/mfd/db8500-prcmu.c b/drivers/mfd/db8500-prcmu.c index 319b8ab..5389368 100644 --- a/drivers/mfd/db8500-prcmu.c +++ b/drivers/mfd/db8500-prcmu.c @@ -3095,6 +3095,7 @@ static struct mfd_cell db8500_prcmu_devs[] = { .num_resources = ARRAY_SIZE(db8500_thsens_resources), .resources = db8500_thsens_resources, .platform_data = &db8500_thsens_data, + .pdata_size = sizeof(db8500_thsens_data), }, }; -- 1.7.10.4