From mboxrd@z Thu Jan 1 00:00:00 1970 From: fkan@apm.com (Feng Kan) Date: Thu, 13 Nov 2014 16:19:56 -0800 Subject: [PATCH V2 2/7] Documentation: arm64: add SCU dts binding documentation to linux kernel In-Reply-To: <1415924401-3013-1-git-send-email-fkan@apm.com> References: <1415924401-3013-1-git-send-email-fkan@apm.com> Message-ID: <1415924401-3013-3-git-send-email-fkan@apm.com> To: linux-arm-kernel@lists.infradead.org List-Id: linux-arm-kernel.lists.infradead.org This add documentation for the SCU system clock unit device tree binding to the kernel. Signed-off-by: Feng Kan --- Documentation/devicetree/bindings/arm/apm/scu.txt | 17 +++++++++++++++++ 1 file changed, 17 insertions(+) create mode 100644 Documentation/devicetree/bindings/arm/apm/scu.txt diff --git a/Documentation/devicetree/bindings/arm/apm/scu.txt b/Documentation/devicetree/bindings/arm/apm/scu.txt new file mode 100644 index 0000000..b45be06 --- /dev/null +++ b/Documentation/devicetree/bindings/arm/apm/scu.txt @@ -0,0 +1,17 @@ +APM X-GENE SoC series SCU Registers + +This system clock unit contain various register that control block resets, +clock enable/disables, clock divisors and other deepsleep registers. + +Properties: + - compatible : should contain two values. First value must be: + - "apm,xgene-scu" + second value must be always "syscon". + + - reg : offset and length of the register set. + +Example : + scu: system-clk-controller at 17000000 { + compatible = "apm,xgene-scu","syscon"; + reg = <0x0 0x17000000 0x0 0x400>; + }; -- 1.9.1