From mboxrd@z Thu Jan 1 00:00:00 1970 From: kishon@ti.com (Kishon Vijay Abraham I) Date: Tue, 23 Jun 2015 17:28:46 +0530 Subject: [PATCH 01/17] phy: ti-pipe3: use ti_pipe3_power_off to power off the PHY during probe In-Reply-To: <1435060743-5511-1-git-send-email-kishon@ti.com> References: <1435060743-5511-1-git-send-email-kishon@ti.com> Message-ID: <1435060743-5511-2-git-send-email-kishon@ti.com> To: linux-arm-kernel@lists.infradead.org List-Id: linux-arm-kernel.lists.infradead.org No functional change. Previously omap_control_phy_power() was used to power off the PHY during probe. But once PIPE3 driver is adapted to use syscon, omap_control_phy_power() cannot be used. Hence used ti_pipe3_power_off to power off the PHY. Signed-off-by: Kishon Vijay Abraham I --- drivers/phy/phy-ti-pipe3.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) diff --git a/drivers/phy/phy-ti-pipe3.c b/drivers/phy/phy-ti-pipe3.c index 08020dc..d784426 100644 --- a/drivers/phy/phy-ti-pipe3.c +++ b/drivers/phy/phy-ti-pipe3.c @@ -431,8 +431,6 @@ static int ti_pipe3_probe(struct platform_device *pdev) phy->control_dev = &control_pdev->dev; - omap_control_phy_power(phy->control_dev, 0); - platform_set_drvdata(pdev, phy); pm_runtime_enable(phy->dev); @@ -451,6 +449,8 @@ static int ti_pipe3_probe(struct platform_device *pdev) return PTR_ERR(generic_phy); phy_set_drvdata(generic_phy, phy); + ti_pipe3_power_off(generic_phy); + phy_provider = devm_of_phy_provider_register(phy->dev, of_phy_simple_xlate); if (IS_ERR(phy_provider)) -- 1.7.9.5