From mboxrd@z Thu Jan 1 00:00:00 1970 From: thomas.petazzoni@free-electrons.com (Thomas Petazzoni) Date: Thu, 14 Apr 2016 17:33:30 +0200 Subject: [PATCH v5 2/5] dt-bindings: arm: add DT binding for Marvell AP806 system controller In-Reply-To: <1460648013-31320-1-git-send-email-thomas.petazzoni@free-electrons.com> References: <1460648013-31320-1-git-send-email-thomas.petazzoni@free-electrons.com> Message-ID: <1460648013-31320-3-git-send-email-thomas.petazzoni@free-electrons.com> To: linux-arm-kernel@lists.infradead.org List-Id: linux-arm-kernel.lists.infradead.org This commit adds the Device Tree binding documentation for the system controller found in Marvell AP806 HW block, which is one of the core HW blocks of the 64-bits Marvell Armada 7K/8K family. Signed-off-by: Thomas Petazzoni Acked-by: Rob Herring --- .../arm/marvell/ap806-system-controller.txt | 35 ++++++++++++++++++++++ 1 file changed, 35 insertions(+) create mode 100644 Documentation/devicetree/bindings/arm/marvell/ap806-system-controller.txt diff --git a/Documentation/devicetree/bindings/arm/marvell/ap806-system-controller.txt b/Documentation/devicetree/bindings/arm/marvell/ap806-system-controller.txt new file mode 100644 index 0000000..8968371 --- /dev/null +++ b/Documentation/devicetree/bindings/arm/marvell/ap806-system-controller.txt @@ -0,0 +1,35 @@ +Marvell Armada AP806 System Controller +====================================== + +The AP806 is one of the two core HW blocks of the Marvell Armada 7K/8K +SoCs. It contains a system controller, which provides a number +registers giving access to numerous features: clocks, pin-muxing and +many other SoC configuration items. This DT binding allows to describe +this system controller. + +The Device Tree node representing the AP806 system controller provides +a number of clocks: + + - 0: clock of CPU cluster 0 + - 1: clock of CPU cluster 1 + - 2: fixed PLL at 1200 Mhz + - 3: MSS clock, derived from the fixed PLL + +Required properties: + + - compatible: must be: + "marvell,ap806-system-controller", "syscon" + - reg: register area of the AP806 system controller + - #clock-cells: must be set to 1 + - clock-output-names: must be defined to: + "ap-cpu-cluster-0", "ap-cpu-cluster-1", "ap-fixed", "ap-mss" + +Example: + + syscon: system-controller at 6f4000 { + compatible = "marvell,ap806-system-controller", "syscon"; + #clock-cells = <1>; + clock-output-names = "ap-cpu-cluster-0", "ap-cpu-cluster-1", + "ap-fixed", "ap-mss"; + reg = <0x6f4000 0x1000>; + }; -- 2.6.4