From: rnayak@codeaurora.org (Rajendra Nayak)
To: linux-arm-kernel@lists.infradead.org
Subject: [PATCH v6 04/11] thermal: core: export apis to get slope and offset
Date: Thu, 5 May 2016 14:21:42 +0530 [thread overview]
Message-ID: <1462438309-11196-5-git-send-email-rnayak@codeaurora.org> (raw)
In-Reply-To: <1462438309-11196-1-git-send-email-rnayak@codeaurora.org>
Add apis for platform thermal drivers to query for slope and offset
attributes, which might be needed for temperature calculations.
Signed-off-by: Rajendra Nayak <rnayak@codeaurora.org>
---
Documentation/thermal/sysfs-api.txt | 12 ++++++++++++
drivers/thermal/thermal_core.c | 30 ++++++++++++++++++++++++++++++
include/linux/thermal.h | 8 ++++++++
3 files changed, 50 insertions(+)
diff --git a/Documentation/thermal/sysfs-api.txt b/Documentation/thermal/sysfs-api.txt
index ed419d6..3450cb0 100644
--- a/Documentation/thermal/sysfs-api.txt
+++ b/Documentation/thermal/sysfs-api.txt
@@ -140,6 +140,18 @@ temperature) and throttle appropriate devices.
Normally this function will not need to be called and the resource
management code will ensure that the resource is freed.
+1.1.7 int thermal_zone_get_slope(struct thermal_zone_device *tz)
+
+ This interface is used to read the slope attribute value
+ for the thermal zone device, which might be useful for platform
+ drivers for temperature calculations.
+
+1.1.8 int thermal_zone_get_offset(struct thermal_zone_device *tz)
+
+ This interface is used to read the offset attribute value
+ for the thermal zone device, which might be useful for platform
+ drivers for temperature calculations.
+
1.2 thermal cooling device interface
1.2.1 struct thermal_cooling_device *thermal_cooling_device_register(char *name,
void *devdata, struct thermal_cooling_device_ops *)
diff --git a/drivers/thermal/thermal_core.c b/drivers/thermal/thermal_core.c
index 5133cd1..b118aae 100644
--- a/drivers/thermal/thermal_core.c
+++ b/drivers/thermal/thermal_core.c
@@ -2065,6 +2065,36 @@ exit:
}
EXPORT_SYMBOL_GPL(thermal_zone_get_zone_by_name);
+/**
+ * thermal_zone_get_slope - return the slope attribute of the thermal zone
+ * @tz: thermal zone device with the slope attribute
+ *
+ * Return: If the thermal zone device has a slope attribute, return it, else
+ * return 1.
+ */
+int thermal_zone_get_slope(struct thermal_zone_device *tz)
+{
+ if (tz && tz->tzp)
+ return tz->tzp->slope;
+ return 1;
+}
+EXPORT_SYMBOL_GPL(thermal_zone_get_slope);
+
+/**
+ * thermal_zone_get_offset - return the offset attribute of the thermal zone
+ * @tz: thermal zone device with the offset attribute
+ *
+ * Return: If the thermal zone device has a offset attribute, return it, else
+ * return 0.
+ */
+int thermal_zone_get_offset(struct thermal_zone_device *tz)
+{
+ if (tz && tz->tzp)
+ return tz->tzp->offset;
+ return 0;
+}
+EXPORT_SYMBOL_GPL(thermal_zone_get_offset);
+
#ifdef CONFIG_NET
static const struct genl_multicast_group thermal_event_mcgrps[] = {
{ .name = THERMAL_GENL_MCAST_GROUP_NAME, },
diff --git a/include/linux/thermal.h b/include/linux/thermal.h
index 1b8a5a7..fd206b9 100644
--- a/include/linux/thermal.h
+++ b/include/linux/thermal.h
@@ -432,6 +432,8 @@ thermal_of_cooling_device_register(struct device_node *np, char *, void *,
void thermal_cooling_device_unregister(struct thermal_cooling_device *);
struct thermal_zone_device *thermal_zone_get_zone_by_name(const char *name);
int thermal_zone_get_temp(struct thermal_zone_device *tz, int *temp);
+int thermal_zone_get_slope(struct thermal_zone_device *tz);
+int thermal_zone_get_offset(struct thermal_zone_device *tz);
int get_tz_trend(struct thermal_zone_device *, int);
struct thermal_instance *get_thermal_instance(struct thermal_zone_device *,
@@ -489,6 +491,12 @@ static inline struct thermal_zone_device *thermal_zone_get_zone_by_name(
static inline int thermal_zone_get_temp(
struct thermal_zone_device *tz, int *temp)
{ return -ENODEV; }
+static inline int thermal_zone_get_slope(
+ struct thermal_zone_device *tz)
+{ return -ENODEV; }
+static inline int thermal_zone_get_offset(
+ struct thermal_zone_device *tz)
+{ return -ENODEV; }
static inline int get_tz_trend(struct thermal_zone_device *tz, int trip)
{ return -ENODEV; }
static inline struct thermal_instance *
--
QUALCOMM INDIA, on behalf of Qualcomm Innovation Center, Inc. is a member
of Code Aurora Forum, hosted by The Linux Foundation
next prev parent reply other threads:[~2016-05-05 8:51 UTC|newest]
Thread overview: 22+ messages / expand[flat|nested] mbox.gz Atom feed top
2016-05-05 8:51 [PATCH v6 00/11] qcom: Add support for TSENS driver Rajendra Nayak
2016-05-05 8:51 ` [PATCH v6 01/11] thermal: qcom: tsens: Add a skeletal TSENS drivers Rajendra Nayak
2016-05-05 8:51 ` [PATCH v6 02/11] thermal: qcom: tsens-8916: Add support for 8916 family of SoCs Rajendra Nayak
2016-05-05 8:51 ` [PATCH v6 03/11] thermal: qcom: tsens-8974: Add support for 8974 " Rajendra Nayak
2016-05-05 8:51 ` Rajendra Nayak [this message]
2016-05-05 8:51 ` [PATCH v6 05/11] thermal: qcom: tsens-8960: Add support for 8960 " Rajendra Nayak
2016-05-05 8:51 ` [PATCH v6 06/11] thermal: qcom: tsens-8996: Add support for 8996 " Rajendra Nayak
2016-05-05 8:51 ` [PATCH v6 07/11] arm: dts: msm8974: Add thermal zones, tsens and qfprom nodes Rajendra Nayak
2016-07-02 1:19 ` Eduardo Valentin
2016-05-05 8:51 ` [PATCH v6 08/11] arm: dts: apq8064: " Rajendra Nayak
2016-05-05 8:51 ` [PATCH v6 09/11] arm: dts: apq8084: " Rajendra Nayak
2016-05-05 8:51 ` [PATCH v6 10/11] arm64: dts: msm8916: " Rajendra Nayak
2016-05-05 8:51 ` [PATCH v6 11/11] arm64: dts: msm8996: " Rajendra Nayak
2016-06-10 6:02 ` [PATCH v6 00/11] qcom: Add support for TSENS driver Rajendra Nayak
2016-06-17 5:59 ` Nayak, Rajendra
2016-06-30 4:25 ` Rajendra Nayak
2016-07-01 20:52 ` Eduardo Valentin
2016-07-02 1:23 ` Eduardo Valentin
2016-07-04 8:04 ` Nayak, Rajendra
2016-07-28 8:33 ` Zhang Rui
2016-07-28 8:55 ` Zhang Rui
2016-08-09 3:51 ` Rajendra Nayak
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
Avoid top-posting and favor interleaved quoting:
https://en.wikipedia.org/wiki/Posting_style#Interleaved_style
* Reply using the --to, --cc, and --in-reply-to
switches of git-send-email(1):
git send-email \
--in-reply-to=1462438309-11196-5-git-send-email-rnayak@codeaurora.org \
--to=rnayak@codeaurora.org \
--cc=linux-arm-kernel@lists.infradead.org \
/path/to/YOUR_REPLY
https://kernel.org/pub/software/scm/git/docs/git-send-email.html
* If your mail client supports setting the In-Reply-To header
via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line
before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).