From mboxrd@z Thu Jan 1 00:00:00 1970 From: broonie@opensource.wolfsonmicro.com (Mark Brown) Date: Tue, 27 Sep 2011 17:13:27 +0100 Subject: [PATCH 5/9] regulator: helper routine to extract fixed_voltage_config In-Reply-To: <4E81E25C.5080500@ti.com> References: <1317118372-17052-1-git-send-email-rnayak@ti.com> <1317118372-17052-6-git-send-email-rnayak@ti.com> <20110927121622.GD4289@opensource.wolfsonmicro.com> <4E81E25C.5080500@ti.com> Message-ID: <20110927161327.GP4289@opensource.wolfsonmicro.com> To: linux-arm-kernel@lists.infradead.org List-Id: linux-arm-kernel.lists.infradead.org On Tue, Sep 27, 2011 at 08:19:00PM +0530, Rajendra Nayak wrote: > On Tuesday 27 September 2011 05:46 PM, Mark Brown wrote: > >On Tue, Sep 27, 2011 at 03:42:48PM +0530, Rajendra Nayak wrote: > >>+Optional properties: > >>+- regulator-fixed-supply: Name of the regulator supply > >This is going to be confusing with respect to the generic regulator > >supply property. > Yes, I guess. Any suggestions on how to make it less > confusing? :-) Call it display-name or something?