From mboxrd@z Thu Jan 1 00:00:00 1970 From: mark.rutland@arm.com (Mark Rutland) Date: Tue, 28 Feb 2017 12:39:08 +0000 Subject: [PATCH v3 03/25] dt-bindings: timer: Document Owl timer In-Reply-To: <20170228063535.32069-4-afaerber@suse.de> References: <20170228063535.32069-1-afaerber@suse.de> <20170228063535.32069-4-afaerber@suse.de> Message-ID: <20170228123908.GG3691@leverpostej> To: linux-arm-kernel@lists.infradead.org List-Id: linux-arm-kernel.lists.infradead.org On Tue, Feb 28, 2017 at 07:35:13AM +0100, Andreas F?rber wrote: > The Actions Semi S500 SoC contains a timer block with two 2 Hz and two > 32-bit timers. The S900 SoC timer block has four 32-bit timers. > > Signed-off-by: Andreas F?rber > --- > v2 -> v3: > * Adopted interrupt-names > * Changed compatible for S500 > * Added S900 compatible and interrupt names > > v2: new > > .../devicetree/bindings/timer/actions,owl-timer.txt | 20 ++++++++++++++++++++ > 1 file changed, 20 insertions(+) > create mode 100644 Documentation/devicetree/bindings/timer/actions,owl-timer.txt > > diff --git a/Documentation/devicetree/bindings/timer/actions,owl-timer.txt b/Documentation/devicetree/bindings/timer/actions,owl-timer.txt > new file mode 100644 > index 0000000..5b4834d > --- /dev/null > +++ b/Documentation/devicetree/bindings/timer/actions,owl-timer.txt > @@ -0,0 +1,20 @@ > +Actions Semi Owl Timer > + > +Required properties: > +- compatible : "actions,s500-timer" for S500 > + "actions,s900-timer" for S900 > +- reg : Offset and length of the register set for the device. > +- interrupts : Should contain the interrupts. > +- interrupt-names : Valid names are: "2Hz0", "2Hz1", > + "Timer0", "Timer1", "Timer2", "Timer3" Sticking to lower case for the names would be preferable. Otherwise, this looks fine. Mark,.