linux-arm-kernel.lists.infradead.org archive mirror
 help / color / mirror / Atom feed
From: edubezval@gmail.com (Eduardo Valentin)
To: linux-arm-kernel@lists.infradead.org
Subject: [PATCH V4 1/2] dt-bindings: thermal: add support for Broadcom's Northstar thermal
Date: Sat, 1 Apr 2017 12:51:38 -0700	[thread overview]
Message-ID: <20170401195136.GD28514@localhost.localdomain> (raw)
In-Reply-To: <20170331201124.656-1-zajec5@gmail.com>

Rafal,

On Fri, Mar 31, 2017 at 10:11:23PM +0200, Rafa? Mi?ecki wrote:
> From: Rafa? Mi?ecki <rafal@milecki.pl>
> 
> This commit documents binding for thermal used in Northstar family SoCs.
> 
> Signed-off-by: Rafa? Mi?ecki <rafal@milecki.pl>
> ---
> V3: Add thermal-zones to the example
>     Rob: Because of this update, I didn't include Acked-by I got for V2
> ---
>  .../devicetree/bindings/thermal/brcm,ns-thermal    | 26 ++++++++++++++++++++++
>  1 file changed, 26 insertions(+)
>  create mode 100644 Documentation/devicetree/bindings/thermal/brcm,ns-thermal
> 
> diff --git a/Documentation/devicetree/bindings/thermal/brcm,ns-thermal b/Documentation/devicetree/bindings/thermal/brcm,ns-thermal
> new file mode 100644
> index 000000000000..c561c7349f17
> --- /dev/null
> +++ b/Documentation/devicetree/bindings/thermal/brcm,ns-thermal
> @@ -0,0 +1,26 @@
> +* Broadcom Northstar Thermal
> +
> +This binding describes thermal sensor that is part of Northstar's DMU (Device
> +Management Unit).
> +
> +Required properties:
> +- compatible : Must be "brcm,ns-thermal"
> +- reg : iomem address range of PVTMON registers
> +- #thermal-sensor-cells : Should be <0>
> +
> +Example:
> +
> +thermal: thermal at 1800c2c0 {
> +	compatible = "brcm,ns-thermal";
> +	reg = <0x1800c2c0 0x10>;
> +	#thermal-sensor-cells = <0>;
> +};
> +
> +thermal-zones {
> +	cpu_thermal: cpu-thermal {
> +		polling-delay-passive = <0>;
> +		polling-delay = <1000>;
> +		coefficients = <(-556) 418000>;
> +		thermal-sensors = <&thermal>;

You need to define trips and cooling devices here. Otherwise, makes
little sense to have this device in thermal subsystem. Here is an
example of minimal set:
https://git.kernel.org/pub/scm/linux/kernel/git/evalenti/linux-soc-thermal.git/commit/?h=linus&id=1e2ac9821de6a85d3e8358f238436708d1d46869

The above has no passive action. It is just gonna shutdown the system if
temperature crosses a threshold. 

But, a typical cooling device would be CPU frequency throttling. Do you have
that up and running in your routers?

> +	};
> +};
> -- 
> 2.11.0
> 

  parent reply	other threads:[~2017-04-01 19:51 UTC|newest]

Thread overview: 31+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
     [not found] <20170318155632.18099-1-zajec5@gmail.com>
2017-03-23 22:30 ` [PATCH V2 1/2] dt-bindings: thermal: add support for Broadcom's Northstar thermal Rafał Miłecki
2017-03-23 22:30   ` [PATCH V2 2/2] thermal: broadcom: add Northstar thermal driver Rafał Miłecki
2017-03-24 14:35     ` Jon Mason
2017-03-31  7:03       ` Rafał Miłecki
2017-03-31 14:23         ` Jon Mason
2017-03-31 14:49           ` Rafał Miłecki
2017-03-31 17:29             ` Jon Mason
2017-03-31  3:15     ` Eduardo Valentin
2017-03-31  7:08       ` Rafał Miłecki
2017-03-31  3:17   ` [PATCH V2 1/2] dt-bindings: thermal: add support for Broadcom's Northstar thermal Eduardo Valentin
2017-03-31  7:31   ` [PATCH V3 " Rafał Miłecki
2017-03-31  7:31     ` [PATCH V3 2/2] thermal: broadcom: add Northstar thermal driver Rafał Miłecki
2017-03-31 20:11       ` [PATCH V4 1/2] dt-bindings: thermal: add support for Broadcom's Northstar thermal Rafał Miłecki
2017-03-31 20:11         ` [PATCH V4 2/2] thermal: broadcom: add Northstar thermal driver Rafał Miłecki
2017-04-01 19:54           ` Eduardo Valentin
2017-04-01 20:20             ` Florian Fainelli
2017-04-01 21:41             ` Rafał Miłecki
2017-04-01 19:51         ` Eduardo Valentin [this message]
2017-04-01 21:50           ` [PATCH V4 1/2] dt-bindings: thermal: add support for Broadcom's Northstar thermal Rafał Miłecki
2017-04-02  4:13             ` Eduardo Valentin
2017-04-03  3:07             ` Jon Mason
2017-04-03 14:54               ` Jon Mason
2017-04-03 14:57                 ` Rafał Miłecki
2017-04-03 15:48         ` [PATCH V5 " Rafał Miłecki
2017-04-03 15:48           ` [PATCH V5 2/2] thermal: broadcom: add Northstar thermal driver Rafał Miłecki
2017-04-07  4:42             ` Eduardo Valentin
2017-04-14 12:16               ` Rafał Miłecki
2017-04-14 15:16                 ` Eduardo Valentin
2017-04-14 15:19                   ` Rafał Miłecki
2017-04-17 20:09                 ` Stefan Wahren
2017-04-10 15:00           ` [PATCH V5 1/2] dt-bindings: thermal: add support for Broadcom's Northstar thermal Rob Herring

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=20170401195136.GD28514@localhost.localdomain \
    --to=edubezval@gmail.com \
    --cc=linux-arm-kernel@lists.infradead.org \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).