From mboxrd@z Thu Jan 1 00:00:00 1970 From: maxime.ripard@bootlin.com (Maxime Ripard) Date: Mon, 28 May 2018 10:44:46 +0200 Subject: [PATCH 06/15] arm: dts: sun: Add missing cooling device properties for CPUs In-Reply-To: References: Message-ID: <20180528084446.g24fphqqac2hi3rr@flea> To: linux-arm-kernel@lists.infradead.org List-Id: linux-arm-kernel.lists.infradead.org Hi, On Fri, May 25, 2018 at 04:01:52PM +0530, Viresh Kumar wrote: > The cooling device properties, like "#cooling-cells" and > "dynamic-power-coefficient", should either be present for all the CPUs > of a cluster or none. If these are present only for a subset of CPUs of > a cluster then things will start falling apart as soon as the CPUs are > brought online in a different order. For example, this will happen > because the operating system looks for such properties in the CPU node > it is trying to bring up, so that it can register a cooling device. > > Add such missing properties. > > Fix other missing properties (clocks, OPP, clock latency) as well to > make it all work. > > Signed-off-by: Viresh Kumar The prefix should be sunxi and not sun, but it looks good to me otherwise. Let me know what your preferred merge method is. Maxime -- Maxime Ripard, Bootlin (formerly Free Electrons) Embedded Linux and Kernel engineering https://bootlin.com -------------- next part -------------- A non-text attachment was scrubbed... Name: signature.asc Type: application/pgp-signature Size: 833 bytes Desc: not available URL: