From mboxrd@z Thu Jan 1 00:00:00 1970 From: miquel.raynal@bootlin.com (Miquel Raynal) Date: Thu, 5 Jul 2018 14:43:33 +0200 Subject: [PATCH v2 06/23] thermal: armada: convert driver to syscon register accesses In-Reply-To: <20180702172918.GA28262@localhost.localdomain> References: <20180625151239.20976-1-miquel.raynal@bootlin.com> <20180625151239.20976-7-miquel.raynal@bootlin.com> <20180626033724.q7radxgjeqtsl7ae@tarshish> <20180626092931.7f0f0ad4@xps13> <20180702172918.GA28262@localhost.localdomain> Message-ID: <20180705144333.2cf0fe6a@xps13> To: linux-arm-kernel@lists.infradead.org List-Id: linux-arm-kernel.lists.infradead.org Hi Eduardo, Eduardo Valentin wrote on Mon, 2 Jul 2018 10:29:19 -0700: > Miquel, > > On Tue, Jun 26, 2018 at 09:29:31AM +0200, Miquel Raynal wrote: > > Hi Baruch, > > > > On Tue, 26 Jun 2018 06:37:24 +0300, Baruch Siach > > wrote: > > > > > Hi Miquel, > > > > > > On Mon, Jun 25, 2018 at 05:12:22PM +0200, Miquel Raynal wrote: > > > > Until recently, only one register was referenced in MVEBU thermal IP > > > > node. Recent changes added a second entry pointing to another > > > > register right next to it. We cannot know for sure that we will not > > > > have to access other registers. That will be actually the case when > > > > overheat interrupt feature will come, where it will be needed to access > > > > DFX registers in the same area. > > > > > > > > This approach is not scalable so intead of adding consinuously memory > > > > areas in the DT (and change de DT bindings, while keeping backward > > > > > > s/de/the/ > > > > Oh and s/intead/instead/ too. > > Can you please fix the minor above and also refresh against linus master > branch? Patch does not apply clean anymore. Sure, I'll send a new version rebased on top of Linus's master branch. Thanks for taking the time to check the series, Miqu?l