From mboxrd@z Thu Jan 1 00:00:00 1970 Return-Path: X-Spam-Checker-Version: SpamAssassin 3.4.0 (2014-02-07) on aws-us-west-2-korg-lkml-1.web.codeaurora.org X-Spam-Level: X-Spam-Status: No, score=-6.0 required=3.0 tests=DKIMWL_WL_HIGH,DKIM_SIGNED, DKIM_VALID,HEADER_FROM_DIFFERENT_DOMAINS,INCLUDES_PATCH,MAILING_LIST_MULTI, SPF_PASS,URIBL_BLOCKED,USER_AGENT_NEOMUTT autolearn=unavailable autolearn_force=no version=3.4.0 Received: from mail.kernel.org (mail.kernel.org [198.145.29.99]) by smtp.lore.kernel.org (Postfix) with ESMTP id 9FDF9C04E53 for ; Wed, 15 May 2019 10:47:09 +0000 (UTC) Received: from bombadil.infradead.org (bombadil.infradead.org [198.137.202.133]) (using TLSv1.2 with cipher ECDHE-RSA-AES256-GCM-SHA384 (256/256 bits)) (No client certificate requested) by mail.kernel.org (Postfix) with ESMTPS id 704142084F for ; Wed, 15 May 2019 10:47:09 +0000 (UTC) Authentication-Results: mail.kernel.org; dkim=pass (2048-bit key) header.d=lists.infradead.org header.i=@lists.infradead.org header.b="AXpWuEqO" DMARC-Filter: OpenDMARC Filter v1.3.2 mail.kernel.org 704142084F Authentication-Results: mail.kernel.org; dmarc=none (p=none dis=none) header.from=arm.com Authentication-Results: mail.kernel.org; spf=none smtp.mailfrom=linux-arm-kernel-bounces+infradead-linux-arm-kernel=archiver.kernel.org@lists.infradead.org DKIM-Signature: v=1; a=rsa-sha256; q=dns/txt; c=relaxed/relaxed; d=lists.infradead.org; s=bombadil.20170209; h=Sender: Content-Transfer-Encoding:Content-Type:Cc:List-Subscribe:List-Help:List-Post: List-Archive:List-Unsubscribe:List-Id:In-Reply-To:MIME-Version:References: Message-ID:Subject:To:From:Date:Reply-To:Content-ID:Content-Description: Resent-Date:Resent-From:Resent-Sender:Resent-To:Resent-Cc:Resent-Message-ID: List-Owner; bh=wgqmvox7/n7RrJ64xhVWJa+L6iGCTyrjXBiB7M0Gx0c=; b=AXpWuEqOerXthU ptKlH9GAeEl4Ii7l0I11Nu3uK4m+i5sXS6Ik/hdhvZcbgPnOLn3FqmskbqxajwGmhibTcJUkRjh7s eYw8y82o6oRcQgyDVhkq2QpQKUx+A6SYMtKFgsV8Xr0drwkqnclxluuZ8W8bMwLQTvWTfPOa5JJx6 dLE0ODjGmotQSopRumdaSLkkMbcSdJPezEGrxUyfUcQndFcExTaZ7WBNXq9Wu12lvQSHW5F0hguRm 4vKUB4nTDuO8M3QmpsIUoJ3WSbsm/G3yEUqXnzTsqZ2KFurgoEmXWmTYmi9qHAjMR+5WoAkcnA/O5 c4Wl0KxaYH/4Oh4siqBQ==; Received: from localhost ([127.0.0.1] helo=bombadil.infradead.org) by bombadil.infradead.org with esmtp (Exim 4.90_1 #2 (Red Hat Linux)) id 1hQrRA-0003iI-6R; Wed, 15 May 2019 10:47:04 +0000 Received: from usa-sjc-mx-foss1.foss.arm.com ([217.140.101.70] helo=foss.arm.com) by bombadil.infradead.org with esmtp (Exim 4.90_1 #2 (Red Hat Linux)) id 1hQrR6-0003hX-14 for linux-arm-kernel@lists.infradead.org; Wed, 15 May 2019 10:47:01 +0000 Received: from usa-sjc-imap-foss1.foss.arm.com (unknown [10.72.51.249]) by usa-sjc-mx-foss1.foss.arm.com (Postfix) with ESMTP id 141AF80D; Wed, 15 May 2019 03:46:58 -0700 (PDT) Received: from queper01-lin (queper01-lin.cambridge.arm.com [10.1.195.48]) by usa-sjc-imap-foss1.foss.arm.com (Postfix) with ESMTPSA id 87C383F703; Wed, 15 May 2019 03:46:55 -0700 (PDT) Date: Wed, 15 May 2019 11:46:54 +0100 From: Quentin Perret To: Viresh Kumar Subject: Re: [PATCH v4 2/3] PM / EM: Expose perf domain struct Message-ID: <20190515104651.tv5odug7ce4zlupc@queper01-lin> References: <20190515082318.7993-1-quentin.perret@arm.com> <20190515082318.7993-3-quentin.perret@arm.com> <0ced18eb-e424-fe6b-b11e-165a3c108170@linaro.org> <20190515091658.sbpg6qiovhtblqyr@queper01-lin> <698400c0-e0a4-4a86-b9df-cdb9bd683c0f@linaro.org> <20190515100748.q3t4kt72h2akdpcs@queper01-lin> <20190515102200.s6uq63qnwea6xtpl@vireshk-i7> <20190515104043.vogspxgkapp6qsny@queper01-lin> MIME-Version: 1.0 Content-Disposition: inline In-Reply-To: <20190515104043.vogspxgkapp6qsny@queper01-lin> User-Agent: NeoMutt/20171215 X-CRM114-Version: 20100106-BlameMichelson ( TRE 0.8.0 (BSD) ) MR-646709E3 X-CRM114-CacheID: sfid-20190515_034700_085961_F250BB8B X-CRM114-Status: GOOD ( 25.74 ) X-BeenThere: linux-arm-kernel@lists.infradead.org X-Mailman-Version: 2.1.21 Precedence: list List-Id: List-Unsubscribe: , List-Archive: List-Post: List-Help: List-Subscribe: , Cc: linux-pm@vger.kernel.org, will.deacon@arm.com, amit.kachhap@gmail.com, Daniel Lezcano , rjw@rjwysocki.net, linux-kernel@vger.kernel.org, edubezval@gmail.com, mka@chromium.org, catalin.marinas@arm.com, rui.zhang@intel.com, javi.merino@kernel.org, ionela.voinescu@arm.com, dietmar.eggemann@arm.com, linux-arm-kernel@lists.infradead.org Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: 7bit Sender: "linux-arm-kernel" Errors-To: linux-arm-kernel-bounces+infradead-linux-arm-kernel=archiver.kernel.org@lists.infradead.org On Wednesday 15 May 2019 at 11:40:44 (+0100), Quentin Perret wrote: > On Wednesday 15 May 2019 at 15:52:00 (+0530), Viresh Kumar wrote: > > On 15-05-19, 12:16, Daniel Lezcano wrote: > > > Viresh what do you think ? > > > > I agree with your last suggestions. They do make sense. > > Good :-) > > So, FWIW, the below compiles w/ or w/o THERMAL_GOV_POWER_ALLOCATOR. I'll > test it and clean it up some more and put it as patch 1 in the series if > that's OK. > > Thanks, > Quentin > > > diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c > index f7c1f49ec87f..ee431848ef71 100644 > --- a/drivers/thermal/cpu_cooling.c > +++ b/drivers/thermal/cpu_cooling.c > @@ -58,7 +58,9 @@ > */ > struct freq_table { > u32 frequency; > +#ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR > u32 power; > +#endif > }; > > /** > @@ -109,28 +111,6 @@ static DEFINE_IDA(cpufreq_ida); > static DEFINE_MUTEX(cooling_list_lock); > static LIST_HEAD(cpufreq_cdev_list); > > -/* Below code defines functions to be used for cpufreq as cooling device */ > - > -/** > - * get_level: Find the level for a particular frequency > - * @cpufreq_cdev: cpufreq_cdev for which the property is required > - * @freq: Frequency > - * > - * Return: level corresponding to the frequency. > - */ > -static unsigned long get_level(struct cpufreq_cooling_device *cpufreq_cdev, > - unsigned int freq) > -{ > - struct freq_table *freq_table = cpufreq_cdev->freq_table; > - unsigned long level; > - > - for (level = 1; level <= cpufreq_cdev->max_level; level++) > - if (freq > freq_table[level].frequency) > - break; > - > - return level - 1; > -} > - > /** > * cpufreq_thermal_notifier - notifier callback for cpufreq policy change. > * @nb: struct notifier_block * with callback info. > @@ -184,6 +164,27 @@ static int cpufreq_thermal_notifier(struct notifier_block *nb, > return NOTIFY_OK; > } > > +#ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR > +/** > + * get_level: Find the level for a particular frequency > + * @cpufreq_cdev: cpufreq_cdev for which the property is required > + * @freq: Frequency > + * > + * Return: level corresponding to the frequency. > + */ > +static unsigned long get_level(struct cpufreq_cooling_device *cpufreq_cdev, > + unsigned int freq) > +{ > + struct freq_table *freq_table = cpufreq_cdev->freq_table; > + unsigned long level; > + > + for (level = 1; level <= cpufreq_cdev->max_level; level++) > + if (freq > freq_table[level].frequency) > + break; > + > + return level - 1; > +} > + > /** > * update_freq_table() - Update the freq table with power numbers > * @cpufreq_cdev: the cpufreq cooling device in which to update the table > @@ -333,80 +334,6 @@ static u32 get_dynamic_power(struct cpufreq_cooling_device *cpufreq_cdev, > return (raw_cpu_power * cpufreq_cdev->last_load) / 100; > } > > -/* cpufreq cooling device callback functions are defined below */ > - > -/** > - * cpufreq_get_max_state - callback function to get the max cooling state. > - * @cdev: thermal cooling device pointer. > - * @state: fill this variable with the max cooling state. > - * > - * Callback for the thermal cooling device to return the cpufreq > - * max cooling state. > - * > - * Return: 0 on success, an error code otherwise. > - */ > -static int cpufreq_get_max_state(struct thermal_cooling_device *cdev, > - unsigned long *state) > -{ > - struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; > - > - *state = cpufreq_cdev->max_level; > - return 0; > -} > - > -/** > - * cpufreq_get_cur_state - callback function to get the current cooling state. > - * @cdev: thermal cooling device pointer. > - * @state: fill this variable with the current cooling state. > - * > - * Callback for the thermal cooling device to return the cpufreq > - * current cooling state. > - * > - * Return: 0 on success, an error code otherwise. > - */ > -static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev, > - unsigned long *state) > -{ > - struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; > - > - *state = cpufreq_cdev->cpufreq_state; > - > - return 0; > -} > - > -/** > - * cpufreq_set_cur_state - callback function to set the current cooling state. > - * @cdev: thermal cooling device pointer. > - * @state: set this variable to the current cooling state. > - * > - * Callback for the thermal cooling device to change the cpufreq > - * current cooling state. > - * > - * Return: 0 on success, an error code otherwise. > - */ > -static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev, > - unsigned long state) > -{ > - struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; > - unsigned int clip_freq; > - > - /* Request state should be less than max_level */ > - if (WARN_ON(state > cpufreq_cdev->max_level)) > - return -EINVAL; > - > - /* Check if the old cooling action is same as new cooling action */ > - if (cpufreq_cdev->cpufreq_state == state) > - return 0; > - > - clip_freq = cpufreq_cdev->freq_table[state].frequency; > - cpufreq_cdev->cpufreq_state = state; > - cpufreq_cdev->clipped_freq = clip_freq; > - > - cpufreq_update_policy(cpufreq_cdev->policy->cpu); > - > - return 0; > -} > - > /** > * cpufreq_get_requested_power() - get the current power > * @cdev: &thermal_cooling_device pointer > @@ -551,22 +478,93 @@ static int cpufreq_power2state(struct thermal_cooling_device *cdev, > power); > return 0; > } > +#endif /* CONFIG_THERMAL_GOV_POWER_ALLOCATOR */ > + > +/* cpufreq cooling device callback functions are defined below */ > + > +/** > + * cpufreq_get_max_state - callback function to get the max cooling state. > + * @cdev: thermal cooling device pointer. > + * @state: fill this variable with the max cooling state. > + * > + * Callback for the thermal cooling device to return the cpufreq > + * max cooling state. > + * > + * Return: 0 on success, an error code otherwise. > + */ > +static int cpufreq_get_max_state(struct thermal_cooling_device *cdev, > + unsigned long *state) > +{ > + struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; > + > + *state = cpufreq_cdev->max_level; > + return 0; > +} > + > +/** > + * cpufreq_get_cur_state - callback function to get the current cooling state. > + * @cdev: thermal cooling device pointer. > + * @state: fill this variable with the current cooling state. > + * > + * Callback for the thermal cooling device to return the cpufreq > + * current cooling state. > + * > + * Return: 0 on success, an error code otherwise. > + */ > +static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev, > + unsigned long *state) > +{ > + struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; > + > + *state = cpufreq_cdev->cpufreq_state; > + > + return 0; > +} > + > +/** > + * cpufreq_set_cur_state - callback function to set the current cooling state. > + * @cdev: thermal cooling device pointer. > + * @state: set this variable to the current cooling state. > + * > + * Callback for the thermal cooling device to change the cpufreq > + * current cooling state. > + * > + * Return: 0 on success, an error code otherwise. > + */ > +static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev, > + unsigned long state) > +{ > + struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; > + unsigned int clip_freq; > + > + /* Request state should be less than max_level */ > + if (WARN_ON(state > cpufreq_cdev->max_level)) > + return -EINVAL; > + > + /* Check if the old cooling action is same as new cooling action */ > + if (cpufreq_cdev->cpufreq_state == state) > + return 0; > + > + clip_freq = cpufreq_cdev->freq_table[state].frequency; > + cpufreq_cdev->cpufreq_state = state; > + cpufreq_cdev->clipped_freq = clip_freq; > + > + cpufreq_update_policy(cpufreq_cdev->policy->cpu); > + > + return 0; > +} > > /* Bind cpufreq callbacks to thermal cooling device ops */ > > static struct thermal_cooling_device_ops cpufreq_cooling_ops = { > - .get_max_state = cpufreq_get_max_state, > - .get_cur_state = cpufreq_get_cur_state, > - .set_cur_state = cpufreq_set_cur_state, > -}; > - > -static struct thermal_cooling_device_ops cpufreq_power_cooling_ops = { > .get_max_state = cpufreq_get_max_state, > .get_cur_state = cpufreq_get_cur_state, > .set_cur_state = cpufreq_set_cur_state, > +#ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR > .get_requested_power = cpufreq_get_requested_power, > .state2power = cpufreq_state2power, > .power2state = cpufreq_power2state, > +#endif > }; > > /* Notifier for cpufreq policy change */ > @@ -674,17 +672,16 @@ __cpufreq_cooling_register(struct device_node *np, > pr_debug("%s: freq:%u KHz\n", __func__, freq); > } > > +#ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR > if (capacitance) { > ret = update_freq_table(cpufreq_cdev, capacitance); > if (ret) { > cdev = ERR_PTR(ret); > goto remove_ida; > } > - > - cooling_ops = &cpufreq_power_cooling_ops; > - } else { > - cooling_ops = &cpufreq_cooling_ops; > } > +#endif > + cooling_ops = &cpufreq_cooling_ops; Argh, that is actually broken with !capacitance and THERMAL_GOV_POWER_ALLOCATOR=y ... Perhaps it's best to keep the two thermal_cooling_device_ops struct separated in the end. > > cdev = thermal_of_cooling_device_register(np, dev_name, cpufreq_cdev, > cooling_ops); _______________________________________________ linux-arm-kernel mailing list linux-arm-kernel@lists.infradead.org http://lists.infradead.org/mailman/listinfo/linux-arm-kernel