linux-arm-kernel.lists.infradead.org archive mirror
 help / color / mirror / Atom feed
From: Ulf Hansson <ulf.hansson@linaro.org>
To: Sudeep Holla <sudeep.holla@arm.com>,
	Cristian Marussi <cristian.marussi@arm.com>,
	Viresh Kumar <vireshk@kernel.org>, Nishanth Menon <nm@ti.com>,
	Stephen Boyd <sboyd@kernel.org>
Cc: Nikunj Kela <nkela@quicinc.com>,
	Prasad Sodagudi <psodagud@quicinc.com>,
	Alexandre Torgue <alexandre.torgue@foss.st.com>,
	Ulf Hansson <ulf.hansson@linaro.org>,
	linux-pm@vger.kernel.org, linux-arm-kernel@lists.infradead.org,
	linux-kernel@vger.kernel.org
Subject: [PATCH v3 02/13] firmware: arm_scmi: Extend perf protocol ops to get information of a domain
Date: Fri, 25 Aug 2023 13:26:22 +0200	[thread overview]
Message-ID: <20230825112633.236607-3-ulf.hansson@linaro.org> (raw)
In-Reply-To: <20230825112633.236607-1-ulf.hansson@linaro.org>

Similar to other protocol ops, it's useful for an scmi module driver to get
some generic information of a performance domain. Therefore, let's add a
new callback to provide this information. The information is currently
limited to the name of the performance domain and whether the set-level
operation is supported, although this can easily be extended if we find the
need for it.

Signed-off-by: Ulf Hansson <ulf.hansson@linaro.org>
---

Changes in v3:
	- Re-based.

---
 drivers/firmware/arm_scmi/perf.c | 47 ++++++++++++++++++++------------
 include/linux/scmi_protocol.h    |  8 ++++++
 2 files changed, 38 insertions(+), 17 deletions(-)

diff --git a/drivers/firmware/arm_scmi/perf.c b/drivers/firmware/arm_scmi/perf.c
index 9fb63dd44c20..d20bb6b8abfa 100644
--- a/drivers/firmware/arm_scmi/perf.c
+++ b/drivers/firmware/arm_scmi/perf.c
@@ -145,7 +145,6 @@ struct scmi_msg_resp_perf_describe_levels_v4 {
 struct perf_dom_info {
 	u32 id;
 	bool set_limits;
-	bool set_perf;
 	bool perf_limit_notify;
 	bool perf_level_notify;
 	bool perf_fastchannels;
@@ -154,7 +153,7 @@ struct perf_dom_info {
 	u32 sustained_freq_khz;
 	u32 sustained_perf_level;
 	u32 mult_factor;
-	char name[SCMI_MAX_STR_SIZE];
+	struct scmi_perf_domain_info info;
 	struct scmi_opp opp[MAX_OPPS];
 	struct scmi_fc_info *fc_info;
 	struct xarray opps_by_idx;
@@ -257,7 +256,7 @@ scmi_perf_domain_attributes_get(const struct scmi_protocol_handle *ph,
 		flags = le32_to_cpu(attr->flags);
 
 		dom_info->set_limits = SUPPORTS_SET_LIMITS(flags);
-		dom_info->set_perf = SUPPORTS_SET_PERF_LVL(flags);
+		dom_info->info.set_perf = SUPPORTS_SET_PERF_LVL(flags);
 		dom_info->perf_limit_notify = SUPPORTS_PERF_LIMIT_NOTIFY(flags);
 		dom_info->perf_level_notify = SUPPORTS_PERF_LEVEL_NOTIFY(flags);
 		dom_info->perf_fastchannels = SUPPORTS_PERF_FASTCHANNELS(flags);
@@ -276,7 +275,8 @@ scmi_perf_domain_attributes_get(const struct scmi_protocol_handle *ph,
 			dom_info->mult_factor =
 					(dom_info->sustained_freq_khz * 1000) /
 					dom_info->sustained_perf_level;
-		strscpy(dom_info->name, attr->name, SCMI_SHORT_NAME_MAX_SIZE);
+		strscpy(dom_info->info.name, attr->name,
+			SCMI_SHORT_NAME_MAX_SIZE);
 	}
 
 	ph->xops->xfer_put(ph, t);
@@ -288,7 +288,7 @@ scmi_perf_domain_attributes_get(const struct scmi_protocol_handle *ph,
 	if (!ret && PROTOCOL_REV_MAJOR(version) >= 0x3 &&
 	    SUPPORTS_EXTENDED_NAMES(flags))
 		ph->hops->extended_name_get(ph, PERF_DOMAIN_NAME_GET,
-					    dom_info->id, dom_info->name,
+					    dom_info->id, dom_info->info.name,
 					    SCMI_MAX_STR_SIZE);
 
 	if (dom_info->level_indexing_mode) {
@@ -430,6 +430,29 @@ static int scmi_perf_num_domains_get(const struct scmi_protocol_handle *ph)
 	return pi->num_domains;
 }
 
+static inline struct perf_dom_info *
+scmi_perf_domain_lookup(const struct scmi_protocol_handle *ph, u32 domain)
+{
+	struct scmi_perf_info *pi = ph->get_priv(ph);
+
+	if (domain >= pi->num_domains)
+		return ERR_PTR(-EINVAL);
+
+	return pi->dom_info + domain;
+}
+
+static const struct scmi_perf_domain_info *
+scmi_perf_info_get(const struct scmi_protocol_handle *ph, u32 domain)
+{
+	struct perf_dom_info *dom;
+
+	dom = scmi_perf_domain_lookup(ph, domain);
+	if (IS_ERR(dom))
+		return ERR_PTR(-EINVAL);
+
+	return &dom->info;
+}
+
 static int scmi_perf_msg_limits_set(const struct scmi_protocol_handle *ph,
 				    u32 domain, u32 max_perf, u32 min_perf)
 {
@@ -453,17 +476,6 @@ static int scmi_perf_msg_limits_set(const struct scmi_protocol_handle *ph,
 	return ret;
 }
 
-static inline struct perf_dom_info *
-scmi_perf_domain_lookup(const struct scmi_protocol_handle *ph, u32 domain)
-{
-	struct scmi_perf_info *pi = ph->get_priv(ph);
-
-	if (domain >= pi->num_domains)
-		return ERR_PTR(-EINVAL);
-
-	return pi->dom_info + domain;
-}
-
 static int __scmi_perf_limits_set(const struct scmi_protocol_handle *ph,
 				  struct perf_dom_info *dom, u32 max_perf,
 				  u32 min_perf)
@@ -819,7 +831,7 @@ static int scmi_dvfs_device_opps_add(const struct scmi_protocol_handle *ph,
 		}
 
 		dev_dbg(dev, "[%d][%s]:: Registered OPP[%d] %lu\n",
-			domain, dom->name, idx, freq);
+			domain, dom->info.name, idx, freq);
 	}
 	return 0;
 }
@@ -956,6 +968,7 @@ scmi_power_scale_get(const struct scmi_protocol_handle *ph)
 
 static const struct scmi_perf_proto_ops perf_proto_ops = {
 	.num_domains_get = scmi_perf_num_domains_get,
+	.info_get = scmi_perf_info_get,
 	.limits_set = scmi_perf_limits_set,
 	.limits_get = scmi_perf_limits_get,
 	.level_set = scmi_perf_level_set,
diff --git a/include/linux/scmi_protocol.h b/include/linux/scmi_protocol.h
index 71b39cbbdace..71923ae63b01 100644
--- a/include/linux/scmi_protocol.h
+++ b/include/linux/scmi_protocol.h
@@ -97,11 +97,17 @@ struct scmi_clk_proto_ops {
 			      u32 clk_id);
 };
 
+struct scmi_perf_domain_info {
+	char name[SCMI_MAX_STR_SIZE];
+	bool set_perf;
+};
+
 /**
  * struct scmi_perf_proto_ops - represents the various operations provided
  *	by SCMI Performance Protocol
  *
  * @num_domains_get: gets the number of supported performance domains
+ * @info_get: get the information of a performance domain
  * @limits_set: sets limits on the performance level of a domain
  * @limits_get: gets limits on the performance level of a domain
  * @level_set: sets the performance level of a domain
@@ -122,6 +128,8 @@ struct scmi_clk_proto_ops {
  */
 struct scmi_perf_proto_ops {
 	int (*num_domains_get)(const struct scmi_protocol_handle *ph);
+	const struct scmi_perf_domain_info __must_check *(*info_get)
+		(const struct scmi_protocol_handle *ph, u32 domain);
 	int (*limits_set)(const struct scmi_protocol_handle *ph, u32 domain,
 			  u32 max_perf, u32 min_perf);
 	int (*limits_get)(const struct scmi_protocol_handle *ph, u32 domain,
-- 
2.34.1


_______________________________________________
linux-arm-kernel mailing list
linux-arm-kernel@lists.infradead.org
http://lists.infradead.org/mailman/listinfo/linux-arm-kernel

  parent reply	other threads:[~2023-08-25 11:27 UTC|newest]

Thread overview: 35+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2023-08-25 11:26 [PATCH v3 00/13] arm_scmi/cpufreq: Add generic performance scaling support Ulf Hansson
2023-08-25 11:26 ` [PATCH v3 01/13] firmware: arm_scmi: Extend perf protocol ops to get number of domains Ulf Hansson
2023-08-25 11:26 ` Ulf Hansson [this message]
2023-08-25 11:26 ` [PATCH v3 03/13] cpufreq: scmi: Prepare to move OF parsing of domain-id to cpufreq Ulf Hansson
2023-09-21 14:28   ` Viresh Kumar
2023-08-25 11:26 ` [PATCH v3 04/13] firmware: arm_scmi: Align perf ops to use domain-id as in-parameter Ulf Hansson
2023-09-21 14:29   ` Viresh Kumar
2023-08-25 11:26 ` [PATCH v3 05/13] firmware: arm_scmi: Drop redundant ->device_domain_id() from perf ops Ulf Hansson
2023-08-25 11:26 ` [PATCH v3 06/13] cpufreq: scmi: Avoid one OF parsing in scmi_get_sharing_cpus() Ulf Hansson
2023-09-21 14:29   ` Viresh Kumar
2023-08-25 11:26 ` [PATCH v3 07/13] cpufreq: scmi: Drop redundant ifdef in scmi_cpufreq_probe() Ulf Hansson
2023-09-21 11:14   ` Sudeep Holla
2023-09-21 13:02     ` Ulf Hansson
2023-09-21 13:29       ` Sudeep Holla
2023-08-25 11:26 ` [PATCH v3 08/13] dt-bindings: arm: cpus: Add a power-domain-name for a performance-domain Ulf Hansson
2023-09-11 13:20   ` Rob Herring
2023-09-21 11:11   ` Sudeep Holla
2023-09-21 13:22     ` Ulf Hansson
2023-09-21 13:35       ` Sudeep Holla
2023-08-25 11:26 ` [PATCH v3 09/13] dt-bindings: firmware: arm,scmi: Extend bindings for protocol@13 Ulf Hansson
2023-09-11 13:20   ` Rob Herring
2023-08-25 11:26 ` [PATCH v3 10/13] dt-bindings: power: Clarify performance capabilities of power-domains Ulf Hansson
2023-09-11 14:40   ` Rob Herring
2023-08-25 11:26 ` [PATCH v3 11/13] cpufreq: scmi: Add support to parse domain-id using #power-domain-cells Ulf Hansson
2023-09-21 11:17   ` Sudeep Holla
2023-09-21 14:30   ` Viresh Kumar
2023-08-25 11:26 ` [PATCH v3 12/13] PM: domains: Allow genpd providers to manage OPP tables directly by its FW Ulf Hansson
2023-09-21 11:20   ` Sudeep Holla
2023-09-21 13:05     ` Ulf Hansson
2023-09-21 13:30       ` Sudeep Holla
2023-08-25 11:26 ` [PATCH v3 13/13] genpd: arm: Add the SCMI performance domain Ulf Hansson
2023-09-14 22:45 ` [PATCH v3 00/13] arm_scmi/cpufreq: Add generic performance scaling support Ulf Hansson
2023-09-18 10:26   ` Sudeep Holla
2023-09-19 10:24     ` Ulf Hansson
2023-09-25  9:39 ` Sudeep Holla

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=20230825112633.236607-3-ulf.hansson@linaro.org \
    --to=ulf.hansson@linaro.org \
    --cc=alexandre.torgue@foss.st.com \
    --cc=cristian.marussi@arm.com \
    --cc=linux-arm-kernel@lists.infradead.org \
    --cc=linux-kernel@vger.kernel.org \
    --cc=linux-pm@vger.kernel.org \
    --cc=nkela@quicinc.com \
    --cc=nm@ti.com \
    --cc=psodagud@quicinc.com \
    --cc=sboyd@kernel.org \
    --cc=sudeep.holla@arm.com \
    --cc=vireshk@kernel.org \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).