On Friday, November 18, 2016 9:16:58 AM CET Krzysztof Kozlowski wrote:
> All Samsung platforms, including the Exynos, are selecting HZ_FIXED with
> 200 Hz.  Unfortunately in case of multiplatform image this affects also
> other platforms when Exynos is enabled.
> 
> This looks like an very old legacy code, dating back to initial
> upstreaming of S3C24xx.  Probably it was required for s3c24xx timer
> driver, which was removed in commit ad38bdd15d5b ("ARM: SAMSUNG: Remove
> unused plat-samsung/time.c").
> 
> Since then, this fixed 200 Hz spread everywhere, including out-of-tree
> Samsung kernels (SoC vendor's and Tizen's).  I believe this choice
> was rather an effect of coincidence instead of conscious choice.
> 
> Exynos uses its own MCT or arch timer and can work with all HZ values.
> Older platforms use newer Samsung PWM timer driver which should handle
> down to 100 Hz.
> 
> Few perf mem and sched tests on Odroid XU3 board (Exynos5422, 4x Cortex
> A7, 4x Cortex A15) show no regressions when switching from 200 Hz to
> other values.
> 
> Reported-by: Lee Jones <lee.jones@linaro.org>
> [Dropping 200_HZ from S3C/S5P suggested by Arnd]
> Reported-by: Arnd Bergmann <arnd@arndb.de>
> Signed-off-by: Krzysztof Kozlowski <krzk@kernel.org>
> Cc: Kukjin Kim <kgene@kernel.org>
> Tested-by: Javier Martinez Canillas <javier@osg.samsung.com>
> 

Acked-by: Arnd Bergmann <arnd@arndb.de>

Maybe add a paragraph about the specific problem:

"On s3c24xx, the PWM counter is only 16 bit wide, and with the
typical 12MHz input clock that overflows every 5.5ms. This works
with HZ=200 or higher but not with HZ=100 which needs a 10ms
interval between ticks. On Later chips (S3C64xx, S5P and EXYNOS),
the counter is 32 bits and does not have this problem.
The new samsung_pwm_timer driver solves the problem by scaling
the input clock by a factor of 50 on s3c24xx, which makes it
less accurate but allows HZ=100 as well as CONFIG_NO_HZ with
fewer wakeups".

	Arnd

  parent reply	other threads:[~2016-11-18  8:46 UTC|newest]

Thread overview: 10+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2016-11-18  7:16 [PATCH v2] ARM: Drop fixed 200 Hz timer requirement from Samsung platforms Krzysztof Kozlowski
2016-11-18  7:57 ` Kukjin Kim
2016-11-18  8:46 ` Arnd Bergmann [this message]
2016-11-18 10:43   ` Sylwester Nawrocki
2016-11-18 11:10     ` Krzysztof Kozlowski
2016-11-21  6:01   ` Tomasz Figa
2016-11-21  8:59     ` Ben Dooks
2016-11-21  9:07       ` Russell King - ARM Linux
2016-11-21  9:24     ` Russell King - ARM Linux
2016-11-18 13:17 ` Lee Jones

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=22757093.ejshJp9T7L@wuerfel \
    --to=arnd@arndb.de \
    --cc=linux-arm-kernel@lists.infradead.org \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox