On 06/17/2015 06:47 AM, Rob Herring wrote:
> On Wed, Jun 17, 2015 at 8:33 AM, Viresh Kumar <viresh.kumar@linaro.org> wrote:
>> On 17-06-15, 08:23, Rob Herring wrote:
>>>> + operating-points-v2 = <&cpu0_opp_table_slow>, <&cpu0_opp_table_fast>;
>>> You've made a fundamental change here in that this can now be a list
>>> of phandles. There should be some description on what a list means
>>> (merge the tables?, select one?).
>> Did you miss the description I wrote few lines earlier or are you
>> asking for something else? This is what I wrote earlier:
>>
>>>> +Devices may want to choose OPP tables at runtime and so can provide a list of
>>>> +phandles here. But only *one* of them should be chosen at runtime.
>> So, clearly only ONE of the tables should be used.
> Yes, never mind.
>
>>> I think this needs to have a defined order and the platform should
>>> know what that is. For example, if you read the efuses and decide you
>>> need the "slow" table, you know to pick the first entry. Then you
>>> don't need opp-name. Does that work for QCom?
>> Why forcing on the order here? For example, consider a case where the
>> platform can have four tables, A B C D. Now DT is free to pass all
>> four or just a subset of those. Like, for some boards table B doesn't
>> stand valid. And so it may wanna pass just A C D. And so keeping these
>> tables in order is going to break for sure. Flexibility is probably
>> better in this case.
> Defined order is a key part of DT bindings. We solve the variable
> length problem with name lists associated with variable length
> property like:
>
> operating-point-names = "slow", "fast";
>
> I'm not a fan of doing this if we can avoid it, but we should at least
> follow the same pattern. Don't send me a patch with that yet, I want
> to hear from Stephen.
>
> You can also use "status" to disable specific tables rather than
> removing from the list.
>
An operating-point(s?)-names property seems ok... but doesn't that mean
that every CPU that uses the OPP has to have the same list of
operating-point-names? It would make sense to me if the operating points
were called something different depending on *which* CPU is using them,
but in this case the only name for the operating point is "slow" or
"fast", etc.
In reality we've assigned them names like speedX-binY-vZ so that we know
which speed bin, voltage bin, and version they're part of. Maybe OPP
node properties like qcom,speed-bin = <u32>, qcom,pvs-bin = <u32>, etc.
would be better? It would make the parsing code slightly more
complicated because it needs to look for 2 or 3 properties instead of a
name property though. Or would having different node names be
acceptable? That would avoid this list of strings.
At the least, operating-points-names will be required on qcom platforms.
A fixed ordering known to the platform would mean that we know exactly
how many voltage bins and speed bins and how many voltage bins per speed
bin are used for a particular SoC, which we've avoided knowing so far.
--
Qualcomm Innovation Center, Inc. is a member of Code Aurora Forum,
a Linux Foundation Collaborative Project
next prev parent reply other threads:[~2015-06-18 1:30 UTC|newest]
Thread overview: 28+ messages / expand[flat|nested] mbox.gz Atom feed top
2015-06-04 16:20 [PATCH V7 0/3] OPP: Introduce OPP (V2) bindings Viresh Kumar
2015-06-04 16:20 ` [PATCH V7 1/3] OPP: Add new bindings to address shortcomings of existing bindings Viresh Kumar
2015-06-04 18:37 ` Stephen Boyd
2015-06-05 2:41 ` Viresh Kumar
2015-06-16 13:34 ` Nishanth Menon
2015-06-04 16:20 ` [PATCH V7 2/3] OPP: Allow multiple OPP tables to be passed via DT Viresh Kumar
2015-06-17 13:23 ` Rob Herring
2015-06-17 13:33 ` Viresh Kumar
2015-06-17 13:47 ` Rob Herring
2015-06-17 14:42 ` Viresh Kumar
2015-06-18 1:30 ` Stephen Boyd [this message]
2015-06-18 2:25 ` Viresh Kumar
2015-06-18 2:50 ` Viresh Kumar
2015-06-19 18:47 ` Stephen Boyd
2015-06-19 18:52 ` Rob Herring
2015-06-20 2:24 ` Viresh Kumar
2015-06-19 18:44 ` Stephen Boyd
2015-06-20 2:18 ` Viresh Kumar
2015-06-04 16:20 ` [PATCH V7 3/3] OPP: Add binding for 'opp-suspend' Viresh Kumar
2015-06-13 8:40 ` Viresh Kumar
2015-06-15 22:30 ` Rafael J. Wysocki
2015-06-15 23:35 ` Rob Herring
2015-06-16 0:31 ` Viresh Kumar
2015-06-16 2:54 ` Viresh Kumar
2015-06-16 19:23 ` Rob Herring
2015-06-16 21:21 ` Rafael J. Wysocki
2015-06-17 2:38 ` Viresh Kumar
2015-06-17 9:38 ` Rafael J. Wysocki
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
Avoid top-posting and favor interleaved quoting:
https://en.wikipedia.org/wiki/Posting_style#Interleaved_style
* Reply using the --to, --cc, and --in-reply-to
switches of git-send-email(1):
git send-email \
--in-reply-to=55821F30.2090802@codeaurora.org \
--to=sboyd@codeaurora.org \
--cc=linux-arm-kernel@lists.infradead.org \
/path/to/YOUR_REPLY
https://kernel.org/pub/software/scm/git/docs/git-send-email.html
* If your mail client supports setting the In-Reply-To header
via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line
before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).