linux-arm-kernel.lists.infradead.org archive mirror
 help / color / mirror / Atom feed
From: Michael Shavit <mshavit@google.com>
To: Jason Gunthorpe <jgg@nvidia.com>
Cc: iommu@lists.linux.dev, Joerg Roedel <joro@8bytes.org>,
	 linux-arm-kernel@lists.infradead.org,
	Robin Murphy <robin.murphy@arm.com>,
	 Will Deacon <will@kernel.org>,
	Eric Auger <eric.auger@redhat.com>,
	 Jean-Philippe Brucker <jean-philippe@linaro.org>,
	Moritz Fischer <mdf@kernel.org>,
	 Nicolin Chen <nicolinc@nvidia.com>,
	patches@lists.linux.dev,
	 Shameerali Kolothum Thodi <shameerali.kolothum.thodi@huawei.com>
Subject: Re: [PATCH v5 15/27] iommu/arm-smmu-v3: Add ssid to struct arm_smmu_master_domain
Date: Tue, 19 Mar 2024 21:31:17 +0800	[thread overview]
Message-ID: <CAKHBV24fgg97mpfiTfeppUEPhSDoQN54BG0GRNi1pw3hDdBeqw@mail.gmail.com> (raw)
In-Reply-To: <15-v5-9a37e0c884ce+31e3-smmuv3_newapi_p2_jgg@nvidia.com>

On Tue, Mar 5, 2024 at 7:44 AM Jason Gunthorpe <jgg@nvidia.com> wrote:
>
> Prepare to allow a S1 domain to be attached to a PASID as well. Keep track
> of the SSID the domain is using on each master in the
> arm_smmu_master_domain.
>
> Tested-by: Nicolin Chen <nicolinc@nvidia.com>
> Signed-off-by: Jason Gunthorpe <jgg@nvidia.com>
> ---
>  .../iommu/arm/arm-smmu-v3/arm-smmu-v3-sva.c   | 15 ++++---
>  drivers/iommu/arm/arm-smmu-v3/arm-smmu-v3.c   | 42 +++++++++++++++----
>  drivers/iommu/arm/arm-smmu-v3/arm-smmu-v3.h   |  5 ++-
>  3 files changed, 43 insertions(+), 19 deletions(-)
>
> diff --git a/drivers/iommu/arm/arm-smmu-v3/arm-smmu-v3-sva.c b/drivers/iommu/arm/arm-smmu-v3/arm-smmu-v3-sva.c
> index 9a285b828e8b12..ab9de8e36c45f5 100644
> --- a/drivers/iommu/arm/arm-smmu-v3/arm-smmu-v3-sva.c
> +++ b/drivers/iommu/arm/arm-smmu-v3/arm-smmu-v3-sva.c
> @@ -47,13 +47,12 @@ arm_smmu_update_s1_domain_cd_entry(struct arm_smmu_domain *smmu_domain)
>                 struct arm_smmu_master *master = master_domain->master;
>                 struct arm_smmu_cd *cdptr;
>
> -               /* S1 domains only support RID attachment right now */
> -               cdptr = arm_smmu_get_cd_ptr(master, IOMMU_NO_PASID);
> +               cdptr = arm_smmu_get_cd_ptr(master, master_domain->ssid);
>                 if (WARN_ON(!cdptr))
>                         continue;
>
>                 arm_smmu_make_s1_cd(&target_cd, master, smmu_domain);
> -               arm_smmu_write_cd_entry(master, IOMMU_NO_PASID, cdptr,
> +               arm_smmu_write_cd_entry(master, master_domain->ssid, cdptr,
>                                         &target_cd);
>         }
>         spin_unlock_irqrestore(&smmu_domain->devices_lock, flags);
> @@ -293,8 +292,8 @@ static void arm_smmu_mm_arch_invalidate_secondary_tlbs(struct mmu_notifier *mn,
>                                                     smmu_domain);
>         }
>
> -       arm_smmu_atc_inv_domain(smmu_domain, mm_get_enqcmd_pasid(mm), start,
> -                               size);
> +       arm_smmu_atc_inv_domain_sva(smmu_domain, mm_get_enqcmd_pasid(mm), start,
> +                                   size);
>  }
>
>  static void arm_smmu_mm_release(struct mmu_notifier *mn, struct mm_struct *mm)
> @@ -331,7 +330,7 @@ static void arm_smmu_mm_release(struct mmu_notifier *mn, struct mm_struct *mm)
>         spin_unlock_irqrestore(&smmu_domain->devices_lock, flags);
>
>         arm_smmu_tlb_inv_asid(smmu_domain->smmu, smmu_mn->cd->asid);
> -       arm_smmu_atc_inv_domain(smmu_domain, mm_get_enqcmd_pasid(mm), 0, 0);
> +       arm_smmu_atc_inv_domain_sva(smmu_domain, mm_get_enqcmd_pasid(mm), 0, 0);
>
>         smmu_mn->cleared = true;
>         mutex_unlock(&sva_lock);
> @@ -410,8 +409,8 @@ static void arm_smmu_mmu_notifier_put(struct arm_smmu_mmu_notifier *smmu_mn)
>          */
>         if (!smmu_mn->cleared) {
>                 arm_smmu_tlb_inv_asid(smmu_domain->smmu, cd->asid);
> -               arm_smmu_atc_inv_domain(smmu_domain, mm_get_enqcmd_pasid(mm), 0,
> -                                       0);
> +               arm_smmu_atc_inv_domain_sva(smmu_domain,
> +                                           mm_get_enqcmd_pasid(mm), 0, 0);
>         }
>
>         /* Frees smmu_mn */
> diff --git a/drivers/iommu/arm/arm-smmu-v3/arm-smmu-v3.c b/drivers/iommu/arm/arm-smmu-v3/arm-smmu-v3.c
> index 45f2190fc31786..26c6b9f6f34fd3 100644
> --- a/drivers/iommu/arm/arm-smmu-v3/arm-smmu-v3.c
> +++ b/drivers/iommu/arm/arm-smmu-v3/arm-smmu-v3.c
> @@ -2030,8 +2030,8 @@ static int arm_smmu_atc_inv_master(struct arm_smmu_master *master)
>         return arm_smmu_cmdq_batch_submit(master->smmu, &cmds);
>  }
>
> -int arm_smmu_atc_inv_domain(struct arm_smmu_domain *smmu_domain, int ssid,
> -                           unsigned long iova, size_t size)
> +static int __arm_smmu_atc_inv_domain(struct arm_smmu_domain *smmu_domain,
> +                                    ioasid_t ssid, unsigned long iova, size_t size)
>  {
>         struct arm_smmu_master_domain *master_domain;
>         int i;
> @@ -2059,8 +2059,6 @@ int arm_smmu_atc_inv_domain(struct arm_smmu_domain *smmu_domain, int ssid,
>         if (!atomic_read(&smmu_domain->nr_ats_masters))
>                 return 0;
>
> -       arm_smmu_atc_inv_to_cmd(ssid, iova, size, &cmd);
> -
>         cmds.num = 0;
>
>         spin_lock_irqsave(&smmu_domain->devices_lock, flags);
> @@ -2071,6 +2069,16 @@ int arm_smmu_atc_inv_domain(struct arm_smmu_domain *smmu_domain, int ssid,
>                 if (!master->ats_enabled)
>                         continue;
>
> +               /*
> +                * Non-zero ssid means SVA is co-opting the S1 domain to issue
> +                * invalidations for SVA PASIDs.
> +                */
> +               if (ssid != IOMMU_NO_PASID)
> +                       arm_smmu_atc_inv_to_cmd(ssid, iova, size, &cmd);
> +               else
> +                       arm_smmu_atc_inv_to_cmd(master_domain->ssid, iova, size,
> +                                               &cmd);
> +
>                 for (i = 0; i < master->num_streams; i++) {
>                         cmd.atc.sid = master->streams[i].id;
>                         arm_smmu_cmdq_batch_add(smmu_domain->smmu, &cmds, &cmd);
> @@ -2081,6 +2089,19 @@ int arm_smmu_atc_inv_domain(struct arm_smmu_domain *smmu_domain, int ssid,
>         return arm_smmu_cmdq_batch_submit(smmu_domain->smmu, &cmds);
>  }
>
> +static int arm_smmu_atc_inv_domain(struct arm_smmu_domain *smmu_domain,
> +                                  unsigned long iova, size_t size)
> +{
> +       return __arm_smmu_atc_inv_domain(smmu_domain, IOMMU_NO_PASID, iova,
> +                                        size);
> +}
> +
> +int arm_smmu_atc_inv_domain_sva(struct arm_smmu_domain *smmu_domain,
> +                               ioasid_t ssid, unsigned long iova, size_t size)
> +{
> +       return __arm_smmu_atc_inv_domain(smmu_domain, ssid, iova, size);
> +}
> +
>  /* IO_PGTABLE API */
>  static void arm_smmu_tlb_inv_context(void *cookie)
>  {
> @@ -2102,7 +2123,7 @@ static void arm_smmu_tlb_inv_context(void *cookie)
>                 cmd.tlbi.vmid   = smmu_domain->s2_cfg.vmid;
>                 arm_smmu_cmdq_issue_cmd_with_sync(smmu, &cmd);
>         }
> -       arm_smmu_atc_inv_domain(smmu_domain, IOMMU_NO_PASID, 0, 0);
> +       arm_smmu_atc_inv_domain(smmu_domain, 0, 0);
>  }
>
>  static void __arm_smmu_tlb_inv_range(struct arm_smmu_cmdq_ent *cmd,
> @@ -2200,7 +2221,7 @@ static void arm_smmu_tlb_inv_range_domain(unsigned long iova, size_t size,
>          * Unfortunately, this can't be leaf-only since we may have
>          * zapped an entire table.
>          */
> -       arm_smmu_atc_inv_domain(smmu_domain, IOMMU_NO_PASID, iova, size);
> +       arm_smmu_atc_inv_domain(smmu_domain, iova, size);
>  }
>
>  void arm_smmu_tlb_inv_range_asid(unsigned long iova, size_t size, int asid,
> @@ -2539,7 +2560,8 @@ static void arm_smmu_disable_pasid(struct arm_smmu_master *master)
>
>  static struct arm_smmu_master_domain *
>  arm_smmu_find_master_domain(struct arm_smmu_domain *smmu_domain,
> -                           struct arm_smmu_master *master)
> +                           struct arm_smmu_master *master,
> +                           ioasid_t ssid)
>  {
>         struct arm_smmu_master_domain *master_domain;
>
> @@ -2547,7 +2569,8 @@ arm_smmu_find_master_domain(struct arm_smmu_domain *smmu_domain,
>
>         list_for_each_entry(master_domain, &smmu_domain->devices,
>                             devices_elm) {
> -               if (master_domain->master == master)
> +               if (master_domain->master == master &&
> +                   master_domain->ssid == ssid)
>                         return master_domain;
>         }
>         return NULL;
> @@ -2580,7 +2603,8 @@ static void arm_smmu_remove_master_domain(struct arm_smmu_master *master,
>                 return;
>
>         spin_lock_irqsave(&smmu_domain->devices_lock, flags);
> -       master_domain = arm_smmu_find_master_domain(smmu_domain, master);
> +       master_domain = arm_smmu_find_master_domain(smmu_domain, master,
> +                                                   IOMMU_NO_PASID);
>         if (master_domain) {
>                 list_del(&master_domain->devices_elm);
>                 kfree(master_domain);
> diff --git a/drivers/iommu/arm/arm-smmu-v3/arm-smmu-v3.h b/drivers/iommu/arm/arm-smmu-v3/arm-smmu-v3.h
> index c4b79bc52991be..98dc5885c48655 100644
> --- a/drivers/iommu/arm/arm-smmu-v3/arm-smmu-v3.h
> +++ b/drivers/iommu/arm/arm-smmu-v3/arm-smmu-v3.h
> @@ -738,6 +738,7 @@ struct arm_smmu_domain {
>  struct arm_smmu_master_domain {
>         struct list_head devices_elm;
>         struct arm_smmu_master *master;
> +       u16 ssid;
>  };

SMMU_IDR1.SSIDSIZE may be up to 20 according to the spec. The value
read from this register is used to populate iommu.max_pasids as well
as to compute the smmu/master ssid_bits fields so u16 is insufficient
here.

>
>  static inline struct arm_smmu_domain *to_smmu_domain(struct iommu_domain *dom)
> @@ -769,8 +770,8 @@ void arm_smmu_tlb_inv_range_asid(unsigned long iova, size_t size, int asid,
>                                  size_t granule, bool leaf,
>                                  struct arm_smmu_domain *smmu_domain);
>  bool arm_smmu_free_asid(struct arm_smmu_ctx_desc *cd);
> -int arm_smmu_atc_inv_domain(struct arm_smmu_domain *smmu_domain, int ssid,
> -                           unsigned long iova, size_t size);
> +int arm_smmu_atc_inv_domain_sva(struct arm_smmu_domain *smmu_domain,
> +                               ioasid_t ssid, unsigned long iova, size_t size);
>
>  #ifdef CONFIG_ARM_SMMU_V3_SVA
>  bool arm_smmu_sva_supported(struct arm_smmu_device *smmu);
> --
> 2.43.2
>

Apart from ssid size issue
Reviewed-by: Michael Shavit <mshavit@google.com>

_______________________________________________
linux-arm-kernel mailing list
linux-arm-kernel@lists.infradead.org
http://lists.infradead.org/mailman/listinfo/linux-arm-kernel

  reply	other threads:[~2024-03-19 13:32 UTC|newest]

Thread overview: 116+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2024-03-04 23:43 [PATCH v5 00/27] Update SMMUv3 to the modern iommu API (part 2/3) Jason Gunthorpe
2024-03-04 23:43 ` [PATCH v5 01/27] iommu/arm-smmu-v3: Do not allow a SVA domain to be set on the wrong PASID Jason Gunthorpe
2024-03-15  3:38   ` Nicolin Chen
2024-03-18 18:16     ` Jason Gunthorpe
2024-03-22 17:48   ` Mostafa Saleh
2024-03-26 18:30     ` Jason Gunthorpe
2024-03-26 19:06       ` Mostafa Saleh
2024-03-26 22:10         ` Jason Gunthorpe
2024-03-04 23:43 ` [PATCH v5 02/27] iommu/arm-smmu-v3: Do not ATC invalidate the entire domain Jason Gunthorpe
2024-03-13  9:18   ` Michael Shavit
2024-03-15  2:24   ` Nicolin Chen
2024-03-16 18:09   ` Moritz Fischer
2024-03-22 17:51   ` Mostafa Saleh
2024-03-04 23:43 ` [PATCH v5 03/27] iommu/arm-smmu-v3: Add a type for the CD entry Jason Gunthorpe
2024-03-13  9:44   ` Michael Shavit
2024-03-16 18:10     ` Moritz Fischer
2024-03-18 18:02     ` Jason Gunthorpe
2024-03-15  3:12   ` Nicolin Chen
2024-03-22 17:52   ` Mostafa Saleh
2024-03-04 23:43 ` [PATCH v5 04/27] iommu/arm-smmu-v3: Add an ops indirection to the STE code Jason Gunthorpe
2024-03-13 11:30   ` Michael Shavit
2024-03-15  4:22   ` Nicolin Chen
2024-03-15  5:20     ` Nicolin Chen
2024-03-18 18:06     ` Jason Gunthorpe
2024-03-22 18:14   ` Mostafa Saleh
2024-03-25 14:11     ` Jason Gunthorpe
2024-03-25 21:01       ` Mostafa Saleh
2024-03-04 23:43 ` [PATCH v5 05/27] iommu/arm-smmu-v3: Make CD programming use arm_smmu_write_entry() Jason Gunthorpe
2024-03-15  7:52   ` Nicolin Chen
2024-03-20 12:46     ` Jason Gunthorpe
2024-03-16 18:14   ` Moritz Fischer
2024-03-23 13:02   ` Mostafa Saleh
2024-03-25 14:25     ` Jason Gunthorpe
2024-03-26 18:30     ` Jason Gunthorpe
2024-03-26 19:12       ` Mostafa Saleh
2024-03-26 22:27         ` Jason Gunthorpe
2024-03-27  9:45           ` Mostafa Saleh
2024-03-27 16:42             ` Jason Gunthorpe
2024-03-04 23:43 ` [PATCH v5 06/27] iommu/arm-smmu-v3: Consolidate clearing a CD table entry Jason Gunthorpe
2024-03-13 11:57   ` Michael Shavit
2024-03-15  6:17   ` Nicolin Chen
2024-03-16 18:15   ` Moritz Fischer
2024-03-22 18:36   ` Mostafa Saleh
2024-03-25 14:14     ` Jason Gunthorpe
2024-03-25 21:02       ` Mostafa Saleh
2024-03-04 23:43 ` [PATCH v5 07/27] iommu/arm-smmu-v3: Move the CD generation for S1 domains into a function Jason Gunthorpe
2024-03-13 12:13   ` Michael Shavit
2024-03-18 18:11     ` Jason Gunthorpe
2024-03-23 13:11   ` Mostafa Saleh
2024-03-25 14:30     ` Jason Gunthorpe
2024-03-04 23:43 ` [PATCH v5 08/27] iommu/arm-smmu-v3: Move allocation of the cdtable into arm_smmu_get_cd_ptr() Jason Gunthorpe
2024-03-13 12:15   ` Michael Shavit
2024-03-16  3:31   ` Nicolin Chen
2024-03-22 19:07   ` Mostafa Saleh
2024-03-25 14:21     ` Jason Gunthorpe
2024-03-25 21:03       ` Mostafa Saleh
2024-03-04 23:43 ` [PATCH v5 09/27] iommu/arm-smmu-v3: Allocate the CD table entry in advance Jason Gunthorpe
2024-03-13 12:17   ` Michael Shavit
2024-03-16  4:16   ` Nicolin Chen
2024-03-18 18:14     ` Jason Gunthorpe
2024-03-22 19:15   ` Mostafa Saleh
2024-03-04 23:43 ` [PATCH v5 10/27] iommu/arm-smmu-v3: Move the CD generation for SVA into a function Jason Gunthorpe
2024-03-16  5:19   ` Nicolin Chen
2024-03-20 13:09     ` Jason Gunthorpe
2024-03-04 23:43 ` [PATCH v5 11/27] iommu/arm-smmu-v3: Build the whole CD in arm_smmu_make_s1_cd() Jason Gunthorpe
2024-03-15 10:04   ` Michael Shavit
2024-03-20 12:50     ` Jason Gunthorpe
2024-03-23 13:20   ` Mostafa Saleh
2024-03-04 23:44 ` [PATCH v5 12/27] iommu/arm-smmu-v3: Start building a generic PASID layer Jason Gunthorpe
2024-03-19 16:11   ` Michael Shavit
2024-03-20 18:32     ` Jason Gunthorpe
2024-03-04 23:44 ` [PATCH v5 13/27] iommu/arm-smmu-v3: Make smmu_domain->devices into an allocated list Jason Gunthorpe
2024-03-19 13:09   ` Michael Shavit
2024-03-04 23:44 ` [PATCH v5 14/27] iommu/arm-smmu-v3: Make changing domains be hitless for ATS Jason Gunthorpe
2024-03-21 12:26   ` Michael Shavit
2024-03-21 13:28     ` Jason Gunthorpe
2024-03-21 14:53       ` Michael Shavit
2024-03-21 14:57         ` Michael Shavit
2024-03-21 17:32         ` Jason Gunthorpe
2024-03-04 23:44 ` [PATCH v5 15/27] iommu/arm-smmu-v3: Add ssid to struct arm_smmu_master_domain Jason Gunthorpe
2024-03-19 13:31   ` Michael Shavit [this message]
2024-03-20 12:53     ` Jason Gunthorpe
2024-03-04 23:44 ` [PATCH v5 16/27] iommu/arm-smmu-v3: Keep track of valid CD entries in the cd_table Jason Gunthorpe
2024-03-19 13:55   ` Michael Shavit
2024-03-20 18:21     ` Jason Gunthorpe
2024-03-04 23:44 ` [PATCH v5 17/27] iommu/arm-smmu-v3: Thread SSID through the arm_smmu_attach_*() interface Jason Gunthorpe
2024-03-04 23:44 ` [PATCH v5 18/27] iommu/arm-smmu-v3: Make SVA allocate a normal arm_smmu_domain Jason Gunthorpe
2024-03-19 14:52   ` Michael Shavit
2024-03-20 23:20     ` Jason Gunthorpe
2024-03-04 23:44 ` [PATCH v5 19/27] iommu/arm-smmu-v3: Keep track of arm_smmu_master_domain for SVA Jason Gunthorpe
2024-03-21 10:47   ` Michael Shavit
2024-03-21 13:55     ` Jason Gunthorpe
2024-03-04 23:44 ` [PATCH v5 20/27] iommu: Add ops->domain_alloc_sva() Jason Gunthorpe
2024-03-19 15:09   ` Michael Shavit
2024-03-04 23:44 ` [PATCH v5 21/27] iommu/arm-smmu-v3: Put the SVA mmu notifier in the smmu_domain Jason Gunthorpe
2024-03-19 16:23   ` Michael Shavit
2024-03-20 18:35     ` Jason Gunthorpe
2024-03-04 23:44 ` [PATCH v5 22/27] iommu/arm-smmu-v3: Consolidate freeing the ASID/VMID Jason Gunthorpe
2024-03-19 16:44   ` Michael Shavit
2024-03-19 18:37     ` Jason Gunthorpe
2024-03-04 23:44 ` [PATCH v5 23/27] iommu/arm-smmu-v3: Move the arm_smmu_asid_xa to per-smmu like vmid Jason Gunthorpe
2024-03-04 23:44 ` [PATCH v5 24/27] iommu/arm-smmu-v3: Bring back SVA BTM support Jason Gunthorpe
2024-03-19 17:07   ` Michael Shavit
2024-03-20 13:05     ` Jason Gunthorpe
2024-03-04 23:44 ` [PATCH v5 25/27] iommu/arm-smmu-v3: Allow IDENTITY/BLOCKED to be set while PASID is used Jason Gunthorpe
2024-03-04 23:44 ` [PATCH v5 26/27] iommu/arm-smmu-v3: Allow a PASID to be set when RID is IDENTITY/BLOCKED Jason Gunthorpe
2024-03-04 23:44 ` [PATCH v5 27/27] iommu/arm-smmu-v3: Allow setting a S1 domain to a PASID Jason Gunthorpe
2024-03-15 10:40 ` [PATCH v5 00/27] Update SMMUv3 to the modern iommu API (part 2/3) Shameerali Kolothum Thodi
2024-03-23 13:38 ` Mostafa Saleh
2024-03-25 14:35   ` Jason Gunthorpe
2024-03-25 21:06     ` Mostafa Saleh
2024-03-25 22:44       ` Jason Gunthorpe
2024-03-25 10:22 ` Mostafa Saleh
2024-03-25 10:44   ` Shameerali Kolothum Thodi
2024-03-25 11:22     ` Mostafa Saleh
2024-03-25 16:47       ` Jason Gunthorpe

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=CAKHBV24fgg97mpfiTfeppUEPhSDoQN54BG0GRNi1pw3hDdBeqw@mail.gmail.com \
    --to=mshavit@google.com \
    --cc=eric.auger@redhat.com \
    --cc=iommu@lists.linux.dev \
    --cc=jean-philippe@linaro.org \
    --cc=jgg@nvidia.com \
    --cc=joro@8bytes.org \
    --cc=linux-arm-kernel@lists.infradead.org \
    --cc=mdf@kernel.org \
    --cc=nicolinc@nvidia.com \
    --cc=patches@lists.linux.dev \
    --cc=robin.murphy@arm.com \
    --cc=shameerali.kolothum.thodi@huawei.com \
    --cc=will@kernel.org \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).