From mboxrd@z Thu Jan 1 00:00:00 1970 Return-Path: Date: Tue, 30 Aug 2016 09:04:44 +0200 From: Simon Horman To: Chris Brandt Cc: Geert Uytterhoeven , Sergei Shtylyov , Michael Turquette , Stephen Boyd , linux-clk@vger.kernel.org, linux-renesas-soc@vger.kernel.org Subject: Re: [PATCH v2] clk: renesas: rz: Select EXTAL vs USB clock Message-ID: <20160830070443.GC12845@verge.net.au> References: <20160825190518.20764-1-chris.brandt@renesas.com> <20160830031358.19468-1-chris.brandt@renesas.com> MIME-Version: 1.0 Content-Type: text/plain; charset=us-ascii In-Reply-To: <20160830031358.19468-1-chris.brandt@renesas.com> List-ID: On Mon, Aug 29, 2016 at 11:13:58PM -0400, Chris Brandt wrote: > Check the MD_CLK pin to determine the current clock mode in order to set > the pll clock parent correctly. > > Signed-off-by: Chris Brandt > --- > v2: > * Switched to reading MD_CLK pin to determine mode Thanks, I have queued this up.