From: Eduardo Valentin <eduardo.valentin@ti.com>
To: swarren@wwwdotorg.org, pawel.moll@arm.com, mark.rutland@arm.com,
ian.campbell@citrix.com, rob.herring@calxeda.com,
linux@roeck-us.net, rui.zhang@intel.com, wni@nvidia.com
Cc: grant.likely@linaro.org, durgadoss.r@intel.com,
linux-pm@vger.kernel.org, devicetree@vger.kernel.org,
lm-sensors@lm-sensors.org, linux-kernel@vger.kernel.org,
"Eduardo Valentin" <eduardo.valentin@ti.com>,
"Benoît Cousson" <bcousson@baylibre.com>,
"Tony Lindgren" <tony@atomide.com>,
"Russell King" <linux@arm.linux.org.uk>,
linux-omap@vger.kernel.org, linux-arm-kernel@lists.infradead.org
Subject: [PATCHv4 14/18] arm: dts: add cooling properties on omap4460 cpu node
Date: Thu, 26 Sep 2013 23:13:21 -0400 [thread overview]
Message-ID: <1380251605-3804-15-git-send-email-eduardo.valentin@ti.com> (raw)
In-Reply-To: <1380251605-3804-1-git-send-email-eduardo.valentin@ti.com>
OMAP4460 devices can reach high temperatures and thus
needs to have cpufreq-cooling on systems running on it.
This patch adds the required cooling device properties
so that cpufreq-cpu0 driver loads the cooling device.
Cc: "Benoît Cousson" <bcousson@baylibre.com>
Cc: Tony Lindgren <tony@atomide.com>
Cc: Rob Herring <rob.herring@calxeda.com>
Cc: Pawel Moll <pawel.moll@arm.com>
Cc: Mark Rutland <mark.rutland@arm.com>
Cc: Stephen Warren <swarren@wwwdotorg.org>
Cc: Ian Campbell <ian.campbell@citrix.com>
Cc: Russell King <linux@arm.linux.org.uk>
Cc: linux-omap@vger.kernel.org
Cc: devicetree@vger.kernel.org
Cc: linux-arm-kernel@lists.infradead.org
Cc: linux-kernel@vger.kernel.org
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
---
arch/arm/boot/dts/omap4460.dtsi | 5 +++++
1 file changed, 5 insertions(+)
diff --git a/arch/arm/boot/dts/omap4460.dtsi b/arch/arm/boot/dts/omap4460.dtsi
index 4d93aba..dc22719 100644
--- a/arch/arm/boot/dts/omap4460.dtsi
+++ b/arch/arm/boot/dts/omap4460.dtsi
@@ -20,6 +20,11 @@
920000 1313000
>;
clock-latency = <300000>; /* From legacy driver */
+
+ /* cooling options */
+ cooling-min-level = <0>;
+ cooling-max-level = <2>;
+ #cooling-cells = <2>; /* min followed by max */
};
};
--
1.8.2.1.342.gfa7285d
next prev parent reply other threads:[~2013-09-27 3:13 UTC|newest]
Thread overview: 31+ messages / expand[flat|nested] mbox.gz Atom feed top
2013-09-27 3:13 [PATCHv4 00/18] device thermal limits represented in device tree nodes (v4) Eduardo Valentin
2013-09-27 3:13 ` [PATCHv4 01/18] thermal: allow registering without .get_temp Eduardo Valentin
2013-09-27 3:13 ` [PATCHv4 02/18] thermal: core: allow binding via .bind when tzp is present Eduardo Valentin
2013-11-06 2:56 ` Wei Ni
2013-09-27 3:13 ` [PATCHv7 03/18] thermal: introduce device tree parser Eduardo Valentin
2013-09-30 15:36 ` Mark Rutland
[not found] ` <20130930153614.GA22259-NuALmloUBlrZROr8t4l/smS4ubULX0JqMm0uRHvK7Nw@public.gmane.org>
2013-09-30 20:47 ` Eduardo Valentin
[not found] ` <1380251605-3804-4-git-send-email-eduardo.valentin-l0cyMroinI0@public.gmane.org>
2013-10-01 2:39 ` [PATCHv8 " Eduardo Valentin
2013-10-07 20:51 ` Mark Rutland
2013-10-08 14:59 ` Eduardo Valentin
2013-11-05 18:08 ` Eduardo Valentin
2013-09-27 3:13 ` [PATCHv4 05/18] thermal: cpu_cooling: introduce of_cpufreq_cooling_register Eduardo Valentin
2013-09-27 3:13 ` [PATCHv4 06/18] cpufreq: cpufreq-cpu0: add dt node parsing for cooling device properties Eduardo Valentin
2013-09-27 3:13 ` [PATCHv4 07/18] hwmon: lm75: expose to thermal fw via DT nodes Eduardo Valentin
2013-09-27 3:13 ` [PATCHv4 09/18] thermal: ti-soc-thermal: use thermal DT infrastructure Eduardo Valentin
2013-09-27 3:13 ` [PATCHv4 10/18] arm: dts: add omap4 CPU thermal data Eduardo Valentin
2013-09-27 3:13 ` [PATCHv4 11/18] arm: dts: add omap4430 " Eduardo Valentin
2013-09-27 12:24 ` Nishanth Menon
2013-09-27 13:20 ` Eduardo Valentin
2013-09-27 13:26 ` Nishanth Menon
2013-09-27 13:42 ` Eduardo Valentin
2013-09-27 3:13 ` [PATCHv4 12/18] arm: dts: add omap4460 " Eduardo Valentin
[not found] ` <1380251605-3804-1-git-send-email-eduardo.valentin-l0cyMroinI0@public.gmane.org>
2013-09-27 3:13 ` [PATCHv4 04/18] thermal: core: introduce thermal_of_cooling_device_register Eduardo Valentin
2013-09-27 3:13 ` [PATCHv4 08/18] hwmon: tmp102: expose to thermal fw via DT nodes Eduardo Valentin
2013-09-27 3:13 ` [PATCHv4 13/18] arm: dts: add cooling properties on omap4430 cpu node Eduardo Valentin
2013-09-27 3:13 ` [PATCHv4 17/18] arm: dts: add omap5 thermal data Eduardo Valentin
2013-09-27 3:13 ` [PATCHv4 18/18] arm: dts: add cooling properties on omap5 cpu node Eduardo Valentin
2013-09-27 3:13 ` Eduardo Valentin [this message]
2013-09-27 3:13 ` [PATCHv4 15/18] arm: dts: add omap5 GPU thermal data Eduardo Valentin
2013-09-27 3:13 ` [PATCHv4 16/18] arm: dts: add omap5 CORE " Eduardo Valentin
2013-09-27 3:15 ` [PATCHv4 00/18] device thermal limits represented in device tree nodes (v4) Eduardo Valentin
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
Avoid top-posting and favor interleaved quoting:
https://en.wikipedia.org/wiki/Posting_style#Interleaved_style
* Reply using the --to, --cc, and --in-reply-to
switches of git-send-email(1):
git send-email \
--in-reply-to=1380251605-3804-15-git-send-email-eduardo.valentin@ti.com \
--to=eduardo.valentin@ti.com \
--cc=bcousson@baylibre.com \
--cc=devicetree@vger.kernel.org \
--cc=durgadoss.r@intel.com \
--cc=grant.likely@linaro.org \
--cc=ian.campbell@citrix.com \
--cc=linux-arm-kernel@lists.infradead.org \
--cc=linux-kernel@vger.kernel.org \
--cc=linux-omap@vger.kernel.org \
--cc=linux-pm@vger.kernel.org \
--cc=linux@arm.linux.org.uk \
--cc=linux@roeck-us.net \
--cc=lm-sensors@lm-sensors.org \
--cc=mark.rutland@arm.com \
--cc=pawel.moll@arm.com \
--cc=rob.herring@calxeda.com \
--cc=rui.zhang@intel.com \
--cc=swarren@wwwdotorg.org \
--cc=tony@atomide.com \
--cc=wni@nvidia.com \
/path/to/YOUR_REPLY
https://kernel.org/pub/software/scm/git/docs/git-send-email.html
* If your mail client supports setting the In-Reply-To header
via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line
before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).