From: Lucas Stach <l.stach@pengutronix.de>
To: Bastian Stender <bst@pengutronix.de>,
Shawn Guo <shawnguo@kernel.org>,
"Rafael J . Wysocki" <rjw@rjwysocki.net>,
Viresh Kumar <viresh.kumar@linaro.org>,
Zhang Rui <rui.zhang@intel.com>,
Leonard Crestez <leonard.crestez@nxp.com>
Cc: devicetree@vger.kernel.org, linux-pm@vger.kernel.org,
linux-imx@nxp.com, Anson Huang <anson.huang@nxp.com>,
kernel@pengutronix.de
Subject: Re: [PATCH v3 1/2] cpufreq: imx6q/thermal: imx: register cooling device depending on OF
Date: Fri, 08 Jun 2018 13:47:17 +0200 [thread overview]
Message-ID: <1528458437.26356.13.camel@pengutronix.de> (raw)
In-Reply-To: <20180608090640.29076-1-bst@pengutronix.de>
Am Freitag, den 08.06.2018, 11:06 +0200 schrieb Bastian Stender:
> The cooling device should be part of the i.MX cpufreq driver, but it
> cannot be removed for the sake of DT stability. So turn the cooling
> device registration into a separate function and perform the
> registration only if the CPU OF node does not have the #cooling-cells
> property.
>
> Use of_cpufreq_power_cooling_register in imx_thermal code to link the
> cooling device to the device tree node provided.
>
> This makes it possible to bind the cpufreq cooling device to a custom
> thermal zone via a cooling-maps entry like:
>
> cooling-maps {
> > map0 {
> > trip = <&board_alert>;
> > cooling-device = <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
> > };
> };
>
> Assuming a cpu node exists with label "cpu0" and #cooling-cells
> property.
>
> Signed-off-by: Bastian Stender <bst@pengutronix.de>
Reviewed-by: Lucas Stach <l.stach@pengutronix.de>
> ---
> Changes since v2:
> - replace of_cpufreq_power_cooling_register with
> of_cpufreq_cooling_register already handling capacitance/#cooling-cells
> properties
>
> Changes since implicit v1 ("cpufreq: imx6q/thermal: imx: move CPU cooling device from thermal to cpufreq",
> > id:20171115092332.9320-1-bst@pengutronix.de):
>
> - create cooling device in imx_thermal in case no #cooling-cells
> property is available instead of removing it (DT stability)
> - fix indentation
> ---
> drivers/cpufreq/imx6q-cpufreq.c | 21 +++++++++++++++++++++
> drivers/thermal/imx_thermal.c | 28 ++++++++++++++++++++++++----
> 2 files changed, 45 insertions(+), 4 deletions(-)
>
> diff --git a/drivers/cpufreq/imx6q-cpufreq.c b/drivers/cpufreq/imx6q-cpufreq.c
> index 83cf631fc9bc..a9259fb0302f 100644
> --- a/drivers/cpufreq/imx6q-cpufreq.c
> +++ b/drivers/cpufreq/imx6q-cpufreq.c
> @@ -9,6 +9,7 @@
> #include <linux/clk.h>
> #include <linux/cpu.h>
> #include <linux/cpufreq.h>
> +#include <linux/cpu_cooling.h>
> #include <linux/err.h>
> #include <linux/module.h>
> #include <linux/of.h>
> @@ -50,6 +51,7 @@ static struct clk_bulk_data clks[] = {
> };
>
> static struct device *cpu_dev;
> +static struct thermal_cooling_device *cdev;
> static bool free_opp;
> static struct cpufreq_frequency_table *freq_table;
> static unsigned int max_freq;
> @@ -191,6 +193,16 @@ static int imx6q_set_target(struct cpufreq_policy *policy, unsigned int index)
> > return 0;
> }
>
> +static void imx6q_cpufreq_ready(struct cpufreq_policy *policy)
> +{
> > + cdev = of_cpufreq_cooling_register(policy);
> +
> > + if (!cdev)
> > + dev_err(cpu_dev,
> > + "running cpufreq without cooling device: %ld\n",
> > + PTR_ERR(cdev));
> +}
> +
> static int imx6q_cpufreq_init(struct cpufreq_policy *policy)
> {
> > int ret;
> @@ -202,13 +214,22 @@ static int imx6q_cpufreq_init(struct cpufreq_policy *policy)
> > return ret;
> }
>
> +static int imx6q_cpufreq_exit(struct cpufreq_policy *policy)
> +{
> > + cpufreq_cooling_unregister(cdev);
> +
> > + return 0;
> +}
> +
> static struct cpufreq_driver imx6q_cpufreq_driver = {
> > .flags = CPUFREQ_NEED_INITIAL_FREQ_CHECK,
> > .verify = cpufreq_generic_frequency_table_verify,
> > .target_index = imx6q_set_target,
> > .get = cpufreq_generic_get,
> > .init = imx6q_cpufreq_init,
> > + .exit = imx6q_cpufreq_exit,
> > .name = "imx6q-cpufreq",
> > + .ready = imx6q_cpufreq_ready,
> > .attr = cpufreq_generic_attr,
> > .suspend = cpufreq_generic_suspend,
> };
> diff --git a/drivers/thermal/imx_thermal.c b/drivers/thermal/imx_thermal.c
> index 334d98be03b9..cbfcca828cd7 100644
> --- a/drivers/thermal/imx_thermal.c
> +++ b/drivers/thermal/imx_thermal.c
> @@ -3,6 +3,7 @@
> // Copyright 2013 Freescale Semiconductor, Inc.
>
> #include <linux/clk.h>
> +#include <linux/cpu.h>
> #include <linux/cpufreq.h>
> #include <linux/cpu_cooling.h>
> #include <linux/delay.h>
> @@ -644,6 +645,27 @@ static const struct of_device_id of_imx_thermal_match[] = {
> };
> MODULE_DEVICE_TABLE(of, of_imx_thermal_match);
>
> +/*
> + * Create cooling device in case no #cooling-cells property is available in
> + * CPU node
> + */
> +static int imx_thermal_register_legacy_cooling(struct imx_thermal_data *data)
> +{
> > + struct device_node *np = of_get_cpu_node(data->policy->cpu, NULL);
> > + int ret;
> +
> > + if (!np || !of_find_property(np, "#cooling-cells", NULL)) {
> > + data->cdev = cpufreq_cooling_register(data->policy);
> > + if (IS_ERR(data->cdev)) {
> > + ret = PTR_ERR(data->cdev);
> > + cpufreq_cpu_put(data->policy);
> > + return ret;
> > + }
> > + }
> +
> > + return 0;
> +}
> +
> static int imx_thermal_probe(struct platform_device *pdev)
> {
> > struct imx_thermal_data *data;
> @@ -724,12 +746,10 @@ static int imx_thermal_probe(struct platform_device *pdev)
> > return -EPROBE_DEFER;
> > }
>
> > - data->cdev = cpufreq_cooling_register(data->policy);
> > - if (IS_ERR(data->cdev)) {
> > - ret = PTR_ERR(data->cdev);
> > + ret = imx_thermal_register_legacy_cooling(data);
> > + if (ret) {
> > dev_err(&pdev->dev,
> > "failed to register cpufreq cooling device: %d\n", ret);
> > - cpufreq_cpu_put(data->policy);
> > return ret;
> > }
>
next prev parent reply other threads:[~2018-06-08 11:47 UTC|newest]
Thread overview: 9+ messages / expand[flat|nested] mbox.gz Atom feed top
2018-06-08 9:06 [PATCH v3 1/2] cpufreq: imx6q/thermal: imx: register cooling device depending on OF Bastian Stender
2018-06-08 9:06 ` [PATCH v3 2/2] ARM: dts: imx: add cooling-cells for cpufreq cooling device Bastian Stender
2018-06-19 9:06 ` Viresh Kumar
2018-06-28 0:59 ` Shawn Guo
2018-06-08 11:47 ` Lucas Stach [this message]
2018-06-19 9:05 ` [PATCH v3 1/2] cpufreq: imx6q/thermal: imx: register cooling device depending on OF Viresh Kumar
2018-06-19 9:22 ` Lucas Stach
2018-06-19 9:31 ` Viresh Kumar
2018-07-04 10:51 ` Rafael J. Wysocki
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
Avoid top-posting and favor interleaved quoting:
https://en.wikipedia.org/wiki/Posting_style#Interleaved_style
* Reply using the --to, --cc, and --in-reply-to
switches of git-send-email(1):
git send-email \
--in-reply-to=1528458437.26356.13.camel@pengutronix.de \
--to=l.stach@pengutronix.de \
--cc=anson.huang@nxp.com \
--cc=bst@pengutronix.de \
--cc=devicetree@vger.kernel.org \
--cc=kernel@pengutronix.de \
--cc=leonard.crestez@nxp.com \
--cc=linux-imx@nxp.com \
--cc=linux-pm@vger.kernel.org \
--cc=rjw@rjwysocki.net \
--cc=rui.zhang@intel.com \
--cc=shawnguo@kernel.org \
--cc=viresh.kumar@linaro.org \
/path/to/YOUR_REPLY
https://kernel.org/pub/software/scm/git/docs/git-send-email.html
* If your mail client supports setting the In-Reply-To header