devicetree.vger.kernel.org archive mirror
 help / color / mirror / Atom feed
* [PATCH] thermal: mt8173: minor mtk_thermal.c cleanups
@ 2017-02-08  5:31 Dawei Chien
  2017-02-09 21:25 ` Matthias Brugger
  0 siblings, 1 reply; 5+ messages in thread
From: Dawei Chien @ 2017-02-08  5:31 UTC (permalink / raw)
  To: Zhang Rui, Eduardo Valentin
  Cc: Rob Herring, Pawel Moll, Mark Rutland, Ian Campbell, Kumar Gala,
	Russell King, Matthias Brugger, linux-pm-u79uwXL29TY76Z2rM5mHXA,
	devicetree-u79uwXL29TY76Z2rM5mHXA,
	linux-kernel-u79uwXL29TY76Z2rM5mHXA,
	linux-arm-kernel-IAPFreCvJWM7uuMidbF8XUB+6BGkLq7r,
	linux-mediatek-IAPFreCvJWM7uuMidbF8XUB+6BGkLq7r,
	srv_heupstream-NuS5LvNUpcJWk0Htik3J/w, Sascha Hauer, Fan Chen,
	Eddie Huang, Yingjoe Chen, Erin Lo, Dawei Chien

Thermal driver should read TEMP_MSR3 if thermal bank with 4 sensors.
However, Currently thermal driver don't need read TEMP_MSR3 since
thermal controller only use 3 sensors for each thermal bank.

Signed-off-by: Dawei Chien <dawei.chien-NuS5LvNUpcJWk0Htik3J/w@public.gmane.org>
---
 drivers/thermal/mtk_thermal.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/thermal/mtk_thermal.c b/drivers/thermal/mtk_thermal.c
index 34169c3..c124151 100644
--- a/drivers/thermal/mtk_thermal.c
+++ b/drivers/thermal/mtk_thermal.c
@@ -191,7 +191,7 @@ struct mtk_thermal {
 };
 
 const int mt8173_msr[MT8173_NUM_SENSORS_PER_ZONE] = {
-	TEMP_MSR0, TEMP_MSR1, TEMP_MSR2, TEMP_MSR2
+	TEMP_MSR0, TEMP_MSR1, TEMP_MSR2, TEMP_MSR3
 };
 
 const int mt8173_adcpnp[MT8173_NUM_SENSORS_PER_ZONE] = {
-- 
1.9.1

--
To unsubscribe from this list: send the line "unsubscribe devicetree" in
the body of a message to majordomo-u79uwXL29TY76Z2rM5mHXA@public.gmane.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html

^ permalink raw reply related	[flat|nested] 5+ messages in thread

* Re: [PATCH] thermal: mt8173: minor mtk_thermal.c cleanups
  2017-02-08  5:31 [PATCH] thermal: mt8173: minor mtk_thermal.c cleanups Dawei Chien
@ 2017-02-09 21:25 ` Matthias Brugger
       [not found]   ` <ebdf54af-6290-9654-c475-53dd580582a0-Re5JQEeQqe8AvxtiuMwx3w@public.gmane.org>
  0 siblings, 1 reply; 5+ messages in thread
From: Matthias Brugger @ 2017-02-09 21:25 UTC (permalink / raw)
  To: Dawei Chien, Zhang Rui, Eduardo Valentin
  Cc: Rob Herring, Pawel Moll, Mark Rutland, Ian Campbell, Kumar Gala,
	Russell King, linux-pm, devicetree, linux-kernel,
	linux-arm-kernel, linux-mediatek, srv_heupstream, Sascha Hauer,
	Fan Chen, Eddie Huang, Yingjoe Chen, Erin Lo



On 02/08/2017 06:31 AM, Dawei Chien wrote:
> Thermal driver should read TEMP_MSR3 if thermal bank with 4 sensors.
> However, Currently thermal driver don't need read TEMP_MSR3 since
> thermal controller only use 3 sensors for each thermal bank.
>
> Signed-off-by: Dawei Chien <dawei.chien@mediatek.com>
> ---

Actually the commit message should state:
Fixes: b7cf0053738c ("thermal: Add Mediatek thermal driver for mt2701.")

...and get backported to v4.9 and v4.10.

Reviewed-by: Matthias Brugger <matthias.bgg@gmail.com>

Regards,
Matthias

>  drivers/thermal/mtk_thermal.c | 2 +-
>  1 file changed, 1 insertion(+), 1 deletion(-)
>
> diff --git a/drivers/thermal/mtk_thermal.c b/drivers/thermal/mtk_thermal.c
> index 34169c3..c124151 100644
> --- a/drivers/thermal/mtk_thermal.c
> +++ b/drivers/thermal/mtk_thermal.c
> @@ -191,7 +191,7 @@ struct mtk_thermal {
>  };
>
>  const int mt8173_msr[MT8173_NUM_SENSORS_PER_ZONE] = {
> -	TEMP_MSR0, TEMP_MSR1, TEMP_MSR2, TEMP_MSR2
> +	TEMP_MSR0, TEMP_MSR1, TEMP_MSR2, TEMP_MSR3
>  };
>
>  const int mt8173_adcpnp[MT8173_NUM_SENSORS_PER_ZONE] = {
>

^ permalink raw reply	[flat|nested] 5+ messages in thread

* Re: [PATCH] thermal: mt8173: minor mtk_thermal.c cleanups
       [not found]   ` <ebdf54af-6290-9654-c475-53dd580582a0-Re5JQEeQqe8AvxtiuMwx3w@public.gmane.org>
@ 2017-02-13  9:01     ` Dawei Chien
  2017-02-19  1:23       ` Eduardo Valentin
  0 siblings, 1 reply; 5+ messages in thread
From: Dawei Chien @ 2017-02-13  9:01 UTC (permalink / raw)
  To: Matthias Brugger
  Cc: Zhang Rui, Eduardo Valentin, Rob Herring, Pawel Moll,
	Mark Rutland, Ian Campbell, Kumar Gala, Russell King,
	linux-pm-u79uwXL29TY76Z2rM5mHXA,
	devicetree-u79uwXL29TY76Z2rM5mHXA,
	linux-kernel-u79uwXL29TY76Z2rM5mHXA,
	linux-arm-kernel-IAPFreCvJWM7uuMidbF8XUB+6BGkLq7r,
	linux-mediatek-IAPFreCvJWM7uuMidbF8XUB+6BGkLq7r,
	srv_heupstream-NuS5LvNUpcJWk0Htik3J/w, Sascha Hauer, Fan Chen,
	Eddie Huang, Yingjoe Chen, Erin Lo

Hi, Matthias,

On Thu, 2017-02-09 at 22:25 +0100, Matthias Brugger wrote:
> 
> On 02/08/2017 06:31 AM, Dawei Chien wrote:
> > Thermal driver should read TEMP_MSR3 if thermal bank with 4 sensors.
> > However, Currently thermal driver don't need read TEMP_MSR3 since
> > thermal controller only use 3 sensors for each thermal bank.
> >
> > Signed-off-by: Dawei Chien <dawei.chien-NuS5LvNUpcJWk0Htik3J/w@public.gmane.org>
> > ---
> 
> Actually the commit message should state:
> Fixes: b7cf0053738c ("thermal: Add Mediatek thermal driver for mt2701.")
> 
> ...and get backported to v4.9 and v4.10.
> 
> Reviewed-by: Matthias Brugger <matthias.bgg-Re5JQEeQqe8AvxtiuMwx3w@public.gmane.org>
> 
> Regards,
> Matthias

Thank you for your review. I would add below commit message on next
version. However, currently 8173 thermal driver would not read TEMP_MSR3
since thermal driver only use 3 sensors on each bank, this patch would
not effect temperature.
Only if thermal driver use 4 sensors on any thermal bank, would read
third sensor two times, and lose fourth sensor of vale.
Fixes: b7cf0053738c ("thermal: Add Mediatek thermal driver for mt2701.")

> >  drivers/thermal/mtk_thermal.c | 2 +-
> >  1 file changed, 1 insertion(+), 1 deletion(-)
> >
> > diff --git a/drivers/thermal/mtk_thermal.c b/drivers/thermal/mtk_thermal.c
> > index 34169c3..c124151 100644
> > --- a/drivers/thermal/mtk_thermal.c
> > +++ b/drivers/thermal/mtk_thermal.c
> > @@ -191,7 +191,7 @@ struct mtk_thermal {
> >  };
> >
> >  const int mt8173_msr[MT8173_NUM_SENSORS_PER_ZONE] = {
> > -	TEMP_MSR0, TEMP_MSR1, TEMP_MSR2, TEMP_MSR2
> > +	TEMP_MSR0, TEMP_MSR1, TEMP_MSR2, TEMP_MSR3
> >  };
> >
> >  const int mt8173_adcpnp[MT8173_NUM_SENSORS_PER_ZONE] = {
> >


--
To unsubscribe from this list: send the line "unsubscribe devicetree" in
the body of a message to majordomo-u79uwXL29TY76Z2rM5mHXA@public.gmane.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html

^ permalink raw reply	[flat|nested] 5+ messages in thread

* Re: [PATCH] thermal: mt8173: minor mtk_thermal.c cleanups
  2017-02-13  9:01     ` Dawei Chien
@ 2017-02-19  1:23       ` Eduardo Valentin
       [not found]         ` <20170219012306.GA28525-bi+AKbBUZKY6gyzm1THtWbp2dZbC/Bob@public.gmane.org>
  0 siblings, 1 reply; 5+ messages in thread
From: Eduardo Valentin @ 2017-02-19  1:23 UTC (permalink / raw)
  To: Dawei Chien
  Cc: Matthias Brugger, Zhang Rui, Rob Herring, Pawel Moll,
	Mark Rutland, Ian Campbell, Kumar Gala, Russell King, linux-pm,
	devicetree, linux-kernel, linux-arm-kernel, linux-mediatek,
	srv_heupstream, Sascha Hauer, Fan Chen, Eddie Huang, Yingjoe Chen,
	Erin Lo

On Mon, Feb 13, 2017 at 05:01:58PM +0800, Dawei Chien wrote:
> Hi, Matthias,
> 
> On Thu, 2017-02-09 at 22:25 +0100, Matthias Brugger wrote:
> > 
> > On 02/08/2017 06:31 AM, Dawei Chien wrote:
> > > Thermal driver should read TEMP_MSR3 if thermal bank with 4 sensors.
> > > However, Currently thermal driver don't need read TEMP_MSR3 since
> > > thermal controller only use 3 sensors for each thermal bank.
> > >
> > > Signed-off-by: Dawei Chien <dawei.chien@mediatek.com>
> > > ---
> > 
> > Actually the commit message should state:
> > Fixes: b7cf0053738c ("thermal: Add Mediatek thermal driver for mt2701.")
> > 
> > ...and get backported to v4.9 and v4.10.
> > 
> > Reviewed-by: Matthias Brugger <matthias.bgg@gmail.com>
> > 
> > Regards,
> > Matthias
> 
> Thank you for your review. I would add below commit message on next
> version. However, currently 8173 thermal driver would not read TEMP_MSR3
> since thermal driver only use 3 sensors on each bank, this patch would
> not effect temperature.
> Only if thermal driver use 4 sensors on any thermal bank, would read
> third sensor two times, and lose fourth sensor of vale.
> Fixes: b7cf0053738c ("thermal: Add Mediatek thermal driver for mt2701.")
> 

Please send a new version with the tag in the commit message.

^ permalink raw reply	[flat|nested] 5+ messages in thread

* Re: [PATCH] thermal: mt8173: minor mtk_thermal.c cleanups
       [not found]         ` <20170219012306.GA28525-bi+AKbBUZKY6gyzm1THtWbp2dZbC/Bob@public.gmane.org>
@ 2017-02-20 11:30           ` Matthias Brugger
  0 siblings, 0 replies; 5+ messages in thread
From: Matthias Brugger @ 2017-02-20 11:30 UTC (permalink / raw)
  To: Eduardo Valentin, Dawei Chien
  Cc: Zhang Rui, Rob Herring, Pawel Moll, Mark Rutland, Ian Campbell,
	Kumar Gala, Russell King, linux-pm-u79uwXL29TY76Z2rM5mHXA,
	devicetree-u79uwXL29TY76Z2rM5mHXA,
	linux-kernel-u79uwXL29TY76Z2rM5mHXA,
	linux-arm-kernel-IAPFreCvJWM7uuMidbF8XUB+6BGkLq7r,
	linux-mediatek-IAPFreCvJWM7uuMidbF8XUB+6BGkLq7r,
	srv_heupstream-NuS5LvNUpcJWk0Htik3J/w, Sascha Hauer, Fan Chen,
	Eddie Huang, Yingjoe Chen, Erin Lo



On 19/02/17 02:23, Eduardo Valentin wrote:
> On Mon, Feb 13, 2017 at 05:01:58PM +0800, Dawei Chien wrote:
>> Hi, Matthias,
>>
>> On Thu, 2017-02-09 at 22:25 +0100, Matthias Brugger wrote:
>>>
>>> On 02/08/2017 06:31 AM, Dawei Chien wrote:
>>>> Thermal driver should read TEMP_MSR3 if thermal bank with 4 sensors.
>>>> However, Currently thermal driver don't need read TEMP_MSR3 since
>>>> thermal controller only use 3 sensors for each thermal bank.
>>>>
>>>> Signed-off-by: Dawei Chien <dawei.chien-NuS5LvNUpcJWk0Htik3J/w@public.gmane.org>
>>>> ---
>>>
>>> Actually the commit message should state:
>>> Fixes: b7cf0053738c ("thermal: Add Mediatek thermal driver for mt2701.")
>>>
>>> ...and get backported to v4.9 and v4.10.
>>>
>>> Reviewed-by: Matthias Brugger <matthias.bgg-Re5JQEeQqe8AvxtiuMwx3w@public.gmane.org>
>>>
>>> Regards,
>>> Matthias
>>
>> Thank you for your review. I would add below commit message on next
>> version. However, currently 8173 thermal driver would not read TEMP_MSR3
>> since thermal driver only use 3 sensors on each bank, this patch would
>> not effect temperature.
>> Only if thermal driver use 4 sensors on any thermal bank, would read
>> third sensor two times, and lose fourth sensor of vale.
>> Fixes: b7cf0053738c ("thermal: Add Mediatek thermal driver for mt2701.")
>>
>
> Please send a new version with the tag in the commit message.
>

And don't forget to add stable-u79uwXL29TY76Z2rM5mHXA@public.gmane.org so that the fix ends up 
in the older kernels as well.

Regards,
Matthias
--
To unsubscribe from this list: send the line "unsubscribe devicetree" in
the body of a message to majordomo-u79uwXL29TY76Z2rM5mHXA@public.gmane.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html

^ permalink raw reply	[flat|nested] 5+ messages in thread

end of thread, other threads:[~2017-02-20 11:30 UTC | newest]

Thread overview: 5+ messages (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2017-02-08  5:31 [PATCH] thermal: mt8173: minor mtk_thermal.c cleanups Dawei Chien
2017-02-09 21:25 ` Matthias Brugger
     [not found]   ` <ebdf54af-6290-9654-c475-53dd580582a0-Re5JQEeQqe8AvxtiuMwx3w@public.gmane.org>
2017-02-13  9:01     ` Dawei Chien
2017-02-19  1:23       ` Eduardo Valentin
     [not found]         ` <20170219012306.GA28525-bi+AKbBUZKY6gyzm1THtWbp2dZbC/Bob@public.gmane.org>
2017-02-20 11:30           ` Matthias Brugger

This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).