From: Amit Sunil Dhamne <amitsd@google.com>
To: Rob Herring <robh@kernel.org>
Cc: Krzysztof Kozlowski <krzk+dt@kernel.org>,
Conor Dooley <conor+dt@kernel.org>,
Greg Kroah-Hartman <gregkh@linuxfoundation.org>,
Badhri Jagan Sridharan <badhri@google.com>,
Sebastian Reichel <sre@kernel.org>,
Heikki Krogerus <heikki.krogerus@linux.intel.com>,
"Rafael J. Wysocki" <rafael@kernel.org>,
Len Brown <len.brown@intel.com>, Pavel Machek <pavel@kernel.org>,
Kyle Tso <kyletso@google.com>,
devicetree@vger.kernel.org, linux-kernel@vger.kernel.org,
linux-usb@vger.kernel.org, linux-pm@vger.kernel.org,
tudor.ambarus@linaro.org, andre.draszik@linaro.org,
peter.griffin@linaro.org
Subject: Re: [PATCH v2 1/5] dt-bindings: connector: extend ports property to model power connections
Date: Wed, 28 May 2025 11:42:24 -0700 [thread overview]
Message-ID: <9376817c-30f1-4ca1-afde-60ebdfd93f53@google.com> (raw)
In-Reply-To: <b4a22161-8cab-4d76-a4b0-4bfd0d79cdc1@google.com>
Hi,
On 5/20/25 1:10 PM, Amit Sunil Dhamne wrote:
> Hi Rob,
>
> Thanks for your response!
>
> On 5/14/25 12:42 PM, Rob Herring wrote:
>> On Wed, May 07, 2025 at 06:00:22PM -0700, Amit Sunil Dhamne wrote:
>>> Extend ports property to model power lines going between connector to
>>> charger or battery/batteries. As an example, connector VBUS can supply
>>> power in & out of the battery for a DRP.
>>>
>>> Additionally, add ports property to maxim,max33359 controller example.
>>>
>>> Signed-off-by: Amit Sunil Dhamne <amitsd@google.com>
>>> ---
>>> .../bindings/connector/usb-connector.yaml | 20 +++++++++++------
>>> .../devicetree/bindings/usb/maxim,max33359.yaml | 25 ++++++++++++++++++++++
>>> 2 files changed, 38 insertions(+), 7 deletions(-)
>>>
>>> diff --git a/Documentation/devicetree/bindings/connector/usb-connector.yaml b/Documentation/devicetree/bindings/connector/usb-connector.yaml
>>> index 11e40d225b9f3a0d0aeea7bf764f1c00a719d615..706094f890026d324e6ece8b0c1e831d04d51eb7 100644
>>> --- a/Documentation/devicetree/bindings/connector/usb-connector.yaml
>>> +++ b/Documentation/devicetree/bindings/connector/usb-connector.yaml
>>> @@ -181,16 +181,16 @@ properties:
>>>
>>> port:
>>> $ref: /schemas/graph.yaml#/properties/port
>>> - description: OF graph bindings modeling a data bus to the connector, e.g.
>>> - there is a single High Speed (HS) port present in this connector. If there
>>> - is more than one bus (several port, with 'reg' property), they can be grouped
>>> - under 'ports'.
>>> + description: OF graph binding to model a logical connection between a device
>>> + and connector. This connection may represent a data bus or power line. For
>>> + e.g. a High Speed (HS) data port present in this connector or VBUS line.
>>> + If there is more than one connection (several port, with 'reg' property),
>>> + they can be grouped under 'ports'.
>> 'port' and 'port@0' are equivalent. So you can't be changing its
>> definition.
> Noted!
>
>
>> I'm not sure showing a power connection with the graph is the right
>> approach.
> I want to provide some more context and rationale behind using this design.
>
> From a hardware perspective:
>
> The max77759/max33359 IC has Type-C port controller, charger, fuel gauge
> (FG) ICs. The Vbus from the connector goes to/from the TCPC and connects
> with the charger IP via circuitry & from there on to the battery. The FG
> is connected to the battery in parallel. As it can be seen that while
> these IPs are interconnected, there's no direct connection of the fuel
> gauge & the connector.
>
> For this feature, I am interested in getting the reference to the FG. As
> per graph description: "...These common bindings do not contain any
> information about the direction or type of the connections, they just
> map their existence." This works for my case because I just want the
> connector to be aware of the Fuel gauge device without imposing a
> specific directionality in terms of power supplier/supplied. This is
> also the reason why I didn't use
> "/schemas/power/supply/power-supply.yaml#power-supplies" binding.
>
>> We have a binding for that already with the regulator binding.
> I haven't explored the option of using regulator bindings. But in my
> case I am interested in fuel gauge and unfortunately, they're modeled as
> power_supply devices.
>
>
>>
>> Perhaps the connector needs to be a supply. It's already using that
>> binding in the supplying power to the connector case.
> Want to clarify, in this case you mean
> /schemas/regulator/regulator.yaml#*-supply$ right?
>
> Adding to my response above, the reason I don't want to impose a
> directionality in terms of supplier/supplied is that in case of USB Dual
> Role Port they're dynamic i.e., when USB is source, the power is
> supplied out of the battery (battery/FG will be supplier) and in case
> USB is sink, battery is supplied power. Whether the connector port is in
> source or sink role is determined on a connection to connection basis.
> Also, the knowledge of the supply direction is of no consequence for
> this feature.
>
>
> Please let me know what you think.
>
> Thanks,
>
> Amit
I wanted to follow up on my previous responses. Please let me know if
you have any further questions or concerns.
Thanks,
Amit
>
>> Rob
next prev parent reply other threads:[~2025-05-28 18:42 UTC|newest]
Thread overview: 20+ messages / expand[flat|nested] mbox.gz Atom feed top
2025-05-08 1:00 [PATCH v2 0/5] Add support for Battery Status & Battery Caps AMS in TCPM Amit Sunil Dhamne via B4 Relay
2025-05-08 1:00 ` [PATCH v2 1/5] dt-bindings: connector: extend ports property to model power connections Amit Sunil Dhamne via B4 Relay
2025-05-08 2:08 ` Rob Herring (Arm)
2025-05-13 5:10 ` Amit Sunil Dhamne
2025-05-14 19:42 ` Rob Herring
2025-05-20 20:10 ` Amit Sunil Dhamne
2025-05-28 18:42 ` Amit Sunil Dhamne [this message]
2025-06-23 22:08 ` Sebastian Reichel
2025-07-08 20:55 ` Amit Sunil Dhamne
2025-05-08 1:00 ` [PATCH v2 2/5] power: supply: core: add helper to get power supply given a fwnode Amit Sunil Dhamne via B4 Relay
2025-06-23 21:21 ` Sebastian Reichel
2025-07-08 0:53 ` Amit Sunil Dhamne
2025-05-08 1:00 ` [PATCH v2 3/5] usb: typec: tcpm: Add support for Battery Status response message Amit Sunil Dhamne via B4 Relay
2025-06-23 21:27 ` Sebastian Reichel
2025-07-08 0:55 ` Amit Sunil Dhamne
2025-05-08 1:00 ` [PATCH v2 4/5] power: supply: core: add vendor and product id properties Amit Sunil Dhamne via B4 Relay
2025-06-23 21:44 ` Sebastian Reichel
2025-07-08 1:05 ` Amit Sunil Dhamne
2025-05-08 1:00 ` [PATCH v2 5/5] usb: typec: tcpm: Add support for Battery Cap response message Amit Sunil Dhamne via B4 Relay
2025-06-23 21:51 ` Sebastian Reichel
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
Avoid top-posting and favor interleaved quoting:
https://en.wikipedia.org/wiki/Posting_style#Interleaved_style
* Reply using the --to, --cc, and --in-reply-to
switches of git-send-email(1):
git send-email \
--in-reply-to=9376817c-30f1-4ca1-afde-60ebdfd93f53@google.com \
--to=amitsd@google.com \
--cc=andre.draszik@linaro.org \
--cc=badhri@google.com \
--cc=conor+dt@kernel.org \
--cc=devicetree@vger.kernel.org \
--cc=gregkh@linuxfoundation.org \
--cc=heikki.krogerus@linux.intel.com \
--cc=krzk+dt@kernel.org \
--cc=kyletso@google.com \
--cc=len.brown@intel.com \
--cc=linux-kernel@vger.kernel.org \
--cc=linux-pm@vger.kernel.org \
--cc=linux-usb@vger.kernel.org \
--cc=pavel@kernel.org \
--cc=peter.griffin@linaro.org \
--cc=rafael@kernel.org \
--cc=robh@kernel.org \
--cc=sre@kernel.org \
--cc=tudor.ambarus@linaro.org \
/path/to/YOUR_REPLY
https://kernel.org/pub/software/scm/git/docs/git-send-email.html
* If your mail client supports setting the In-Reply-To header
via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line
before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).