On Tue, Jul 28, 2026 at 10:56:04PM -0700, Guenter Roeck wrote: > On 7/28/26 21:46, Luiz Angelo Daros de Luca wrote: > > The ADT7470 features four PWM outputs designed to control fans. > > Previously, these were only accessible through the legacy hwmon > > sysfs interface. > > > > Expose the ADT7470 fan control lines through the generic PWM framework. > > This allows generic PWM consumers described in Device Tree, such as > > "pwm-fan", to use the device through the "#pwm-cells" property. This is > > particularly necessary for boards where the ADT7470 external temperature > > sensors are not populated and the chip is used strictly as a fan > > controller (e.g., Edgecore ECS-2100-52T switches). In such setups, > > delegating control to the generic PWM subsystem allows the kernel's > > thermal framework to manage the fans based on unrelated temperature > > zones, such as internal SoC sensors. > > > > When a PWM consumer applies a new PWM state, the driver automatically > > switches the corresponding PWM channel to manual mode so that the > > requested duty cycle takes effect. The duty cycle specified by the PWM > > framework is internally converted to the 0-255 scale expected by the > > hardware registers. > > > > The legacy sysfs interface remains unaffected and operates in parallel. > > No, I won't accept this. It has to be either or. A pwm channel modeled as pwm > subsystem channel must not be visible via hwmon attributes. I didn't look in detail, but maybe my red line is a bit more lax. IMHO it's not OK to be able to modify a setting that results from pushing hwmon knobs using PWM operations or vice-versa. Switching between exclusive use at runtime is IMHO ok. Best regards Uwe