linux-doc.vger.kernel.org archive mirror
 help / color / mirror / Atom feed
* [PATCH v6 0/2] Export fan control and register fans as cooling devices
@ 2025-07-18  7:08 Sung-Chi Li via B4 Relay
  2025-07-18  7:08 ` [PATCH v6 1/2] hwmon: (cros_ec) add PWM control over fans Sung-Chi Li via B4 Relay
  2025-07-18  7:08 ` [PATCH v6 2/2] hwmon: (cros_ec) register fans into thermal framework cooling devices Sung-Chi Li via B4 Relay
  0 siblings, 2 replies; 7+ messages in thread
From: Sung-Chi Li via B4 Relay @ 2025-07-18  7:08 UTC (permalink / raw)
  To: Benson Leung, Guenter Roeck, Thomas Weißschuh, Jean Delvare,
	Guenter Roeck, Jonathan Corbet, Thomas Weißschuh
  Cc: chrome-platform, linux-kernel, linux-hwmon, linux-doc,
	Sung-Chi Li, Sung-Chi Li

This is a continuation of the previous series "Export the target RPM fan
control by ChromeOS EC under hwmon"
(https://lore.kernel.org/lkml/20250313-extend_ec_hwmon_fan-v1-0-5c566776f2c4@chromium.org/T/#t).
There is a change from controlling the target fan RPM value to control
the PWM value.

We anticipate to involve fans connected to EC as thermal cooling
devices, so we can utilize the thermal framework to have further thermal
control strategies.

This series updates the required EC controls definitions, implements the
mechanism for controlling fan PWM values, and registers these fans under
thermal framework as cooling devices.

Adapting comments from the previous series, the driver probes the host
command capability at beginning to see whether a fan is controllable:
  - if command `EC_CMD_PWM_GET_FAN_DUTY` is supported (v0, this is a
    new command).
  - if command `EC_CMD_THERMAL_AUTO_FAN_CTRL` v2 is supported.
  - if command `EC_CMD_PWM_SET_FAN_DUTY` v1 is supported.

This combination is selected as this is the minimum requirement for a
fan to be fully controllable under hwmon framework.

The driver supports changing the fan control mode, and allows to change
the fan PWM value only if the fan is in manual control mode. The power
management hook is implemented as well for keeping the fan control
settings, as EC will automatically restore the control method to auto
when device is suspended.

Change-Id: I4e2fdc8c4bc50778c0d04cfbefeaab7088d3181e
Signed-off-by: Sung-Chi Li <lschyi@google.com>
---
Changes in v6:
- Fix lines over 100 characters.
- Remove unnecessary out of memory message.
- Link to v5: https://lore.kernel.org/r/20250620-cros_ec_fan-v5-0-5979ea1abb31@chromium.org

Changes in v5:
- Fix line breaks.
- Directly return 0 when there is no error (rather than return ret
  variable).
- Rename CROS to CrOS.
- Preserve Acked-by and Reviewed-by tags.
- Link to v4: https://lore.kernel.org/r/20250619-cros_ec_fan-v4-0-ca11548ce449@chromium.org

Changes in v4:
- Treat fan control is supported without `CONFIG_PM` is enabled.
- Change logic of registering cooling devices for fan from abandom
  immediately to log warning logs, then continue with the next fan.
- Fix error checking logic to use IS_ERR for
  devm_thermal_of_cooling_device_register.
- Revise variable declaration ordering with reverse christmas tree.
- Rename member variable `manual_fan_pwm_values` to `manual_fan_pwm`.
- Use %pe for printing error pointers, and add newline for logs.
- Revise comments in suspend and resume hook.
- Link to v3: https://lore.kernel.org/r/20250512-cros_ec_fan-v3-0-a9f2b255f0cd@chromium.org

Changes in v3:
- Make required EC command versions macros.
- Add `CONFIG_THERMAL` guarding for registering as thermal fan cooling
  devices.
- Add error handling during registering thermal cooling devices, and
  immediately abort the registration if any error occurred to align with
  the thermal sensor registration in hwmon core.
- Add error handling for EC fan communication during suspend and resume.
- Add `CONFIG_PM` guarding for checking whether the EC supports a
  complete fan control in hwmon driver.
- Sort variables order in declaration.
- Separate declaration and logic to different sections.
- Move `cros_ec_thermal_cooling_ops` next right after the operation
  functions declaration.
- Improve describing the resume behavior in documentation.

Changes in v2:
- Change column from 80 to 100 and fix styles.
- Directly store driver data into platform dev with
  platform_set_drvdata.
- Unify the PWM unit (from 0 ~ 255) between hwmon and thermal cooling
  devices.
- Only fetch the fan control mode and PWM value when suspending rather
  than caching values when writing. The suspend hook is thus added.
- Link to v1: https://lore.kernel.org/r/20250429-cros_ec_fan-v1-0-a8d9e3efbb1a@chromium.org

---
Sung-Chi Li (2):
      hwmon: (cros_ec) add PWM control over fans
      hwmon: (cros_ec) register fans into thermal framework cooling devices

 Documentation/hwmon/cros_ec_hwmon.rst |   7 +-
 drivers/hwmon/cros_ec_hwmon.c         | 313 ++++++++++++++++++++++++++++++++++
 2 files changed, 319 insertions(+), 1 deletion(-)
---
base-commit: 024e09e444bd2b06aee9d1f3fe7b313c7a2df1bb
change-id: 20250429-cros_ec_fan-da3b64ac9c10

Best regards,
-- 
Sung-Chi Li <lschyi@chromium.org>



^ permalink raw reply	[flat|nested] 7+ messages in thread

* [PATCH v6 1/2] hwmon: (cros_ec) add PWM control over fans
  2025-07-18  7:08 [PATCH v6 0/2] Export fan control and register fans as cooling devices Sung-Chi Li via B4 Relay
@ 2025-07-18  7:08 ` Sung-Chi Li via B4 Relay
  2025-07-18 17:37   ` Guenter Roeck
  2025-07-19  4:45   ` Guenter Roeck
  2025-07-18  7:08 ` [PATCH v6 2/2] hwmon: (cros_ec) register fans into thermal framework cooling devices Sung-Chi Li via B4 Relay
  1 sibling, 2 replies; 7+ messages in thread
From: Sung-Chi Li via B4 Relay @ 2025-07-18  7:08 UTC (permalink / raw)
  To: Benson Leung, Guenter Roeck, Thomas Weißschuh, Jean Delvare,
	Guenter Roeck, Jonathan Corbet, Thomas Weißschuh
  Cc: chrome-platform, linux-kernel, linux-hwmon, linux-doc,
	Sung-Chi Li, Sung-Chi Li

From: Sung-Chi Li <lschyi@chromium.org>

Newer EC firmware supports controlling fans through host commands, so
adding corresponding implementations for controlling these fans in the
driver for other kernel services and userspace to control them.

The driver will first probe the supported host command versions (get and
set of fan PWM values, get and set of fan control mode) to see if the
connected EC fulfills the requirements of controlling the fan, then
exposes corresponding sysfs nodes for userspace to control the fan with
corresponding read and write implementations.
As EC will automatically change the fan mode to auto when the device is
suspended, the power management hooks are added as well to keep the fan
control mode and fan PWM value consistent during suspend and resume. As
we need to access the hwmon device in the power management hook, update
the driver by storing the hwmon device in the driver data as well.

Signed-off-by: Sung-Chi Li <lschyi@chromium.org>
Acked-by: Thomas Weißschuh <linux@weissschuh.net>
---
 Documentation/hwmon/cros_ec_hwmon.rst |   5 +-
 drivers/hwmon/cros_ec_hwmon.c         | 230 ++++++++++++++++++++++++++++++++++
 2 files changed, 234 insertions(+), 1 deletion(-)

diff --git a/Documentation/hwmon/cros_ec_hwmon.rst b/Documentation/hwmon/cros_ec_hwmon.rst
index 47ecae983bdbef4bfcafc5dd2fff3de039f77f8e..355557a08c9a54b4c177bafde3743e7dc02218be 100644
--- a/Documentation/hwmon/cros_ec_hwmon.rst
+++ b/Documentation/hwmon/cros_ec_hwmon.rst
@@ -23,4 +23,7 @@ ChromeOS embedded controller used in Chromebooks and other devices.
 
 The channel labels exposed via hwmon are retrieved from the EC itself.
 
-Fan and temperature readings are supported.
+Fan and temperature readings are supported. PWM fan control is also supported if
+the EC also supports setting fan PWM values and fan mode. Note that EC will
+switch fan control mode back to auto when suspended. This driver will restore
+the fan state to what they were before suspended when resumed.
diff --git a/drivers/hwmon/cros_ec_hwmon.c b/drivers/hwmon/cros_ec_hwmon.c
index 9991c3fa020ac859cbbff29dfb669e53248df885..9eddc554ddefde42f70c09689b64ad9e636a3020 100644
--- a/drivers/hwmon/cros_ec_hwmon.c
+++ b/drivers/hwmon/cros_ec_hwmon.c
@@ -7,6 +7,7 @@
 
 #include <linux/device.h>
 #include <linux/hwmon.h>
+#include <linux/math.h>
 #include <linux/mod_devicetable.h>
 #include <linux/module.h>
 #include <linux/platform_device.h>
@@ -17,10 +18,17 @@
 
 #define DRV_NAME	"cros-ec-hwmon"
 
+#define CROS_EC_HWMON_PWM_GET_FAN_DUTY_CMD_VERSION	0
+#define CROS_EC_HWMON_PWM_SET_FAN_DUTY_CMD_VERSION	1
+#define CROS_EC_HWMON_THERMAL_AUTO_FAN_CTRL_CMD_VERSION	2
+
 struct cros_ec_hwmon_priv {
 	struct cros_ec_device *cros_ec;
 	const char *temp_sensor_names[EC_TEMP_SENSOR_ENTRIES + EC_TEMP_SENSOR_B_ENTRIES];
 	u8 usable_fans;
+	bool fan_control_supported;
+	u8 manual_fans; /* bits to indicate whether the fan is set to manual */
+	u8 manual_fan_pwm[EC_FAN_SPEED_ENTRIES];
 };
 
 static int cros_ec_hwmon_read_fan_speed(struct cros_ec_device *cros_ec, u8 index, u16 *speed)
@@ -36,6 +44,42 @@ static int cros_ec_hwmon_read_fan_speed(struct cros_ec_device *cros_ec, u8 index
 	return 0;
 }
 
+static int cros_ec_hwmon_read_pwm_value(struct cros_ec_device *cros_ec, u8 index, u8 *pwm_value)
+{
+	struct ec_params_pwm_get_fan_duty req = {
+		.fan_idx = index,
+	};
+	struct ec_response_pwm_get_fan_duty resp;
+	int ret;
+
+	ret = cros_ec_cmd(cros_ec, CROS_EC_HWMON_PWM_GET_FAN_DUTY_CMD_VERSION,
+			  EC_CMD_PWM_GET_FAN_DUTY, &req, sizeof(req), &resp, sizeof(resp));
+	if (ret < 0)
+		return ret;
+
+	*pwm_value = (u8)DIV_ROUND_CLOSEST(le32_to_cpu(resp.percent) * 255, 100);
+	return 0;
+}
+
+static int cros_ec_hwmon_read_pwm_enable(struct cros_ec_device *cros_ec, u8 index,
+					 u8 *control_method)
+{
+	struct ec_params_auto_fan_ctrl_v2 req = {
+		.cmd = EC_AUTO_FAN_CONTROL_CMD_GET,
+		.fan_idx = index,
+	};
+	struct ec_response_auto_fan_control resp;
+	int ret;
+
+	ret = cros_ec_cmd(cros_ec, CROS_EC_HWMON_THERMAL_AUTO_FAN_CTRL_CMD_VERSION,
+			  EC_CMD_THERMAL_AUTO_FAN_CTRL, &req, sizeof(req), &resp, sizeof(resp));
+	if (ret < 0)
+		return ret;
+
+	*control_method = resp.is_auto ? 2 : 1;
+	return 0;
+}
+
 static int cros_ec_hwmon_read_temp(struct cros_ec_device *cros_ec, u8 index, u8 *temp)
 {
 	unsigned int offset;
@@ -75,6 +119,8 @@ static int cros_ec_hwmon_read(struct device *dev, enum hwmon_sensor_types type,
 {
 	struct cros_ec_hwmon_priv *priv = dev_get_drvdata(dev);
 	int ret = -EOPNOTSUPP;
+	u8 control_method;
+	u8 pwm_value;
 	u16 speed;
 	u8 temp;
 
@@ -92,6 +138,17 @@ static int cros_ec_hwmon_read(struct device *dev, enum hwmon_sensor_types type,
 			if (ret == 0)
 				*val = cros_ec_hwmon_is_error_fan(speed);
 		}
+	} else if (type == hwmon_pwm) {
+		if (attr == hwmon_pwm_enable) {
+			ret = cros_ec_hwmon_read_pwm_enable(priv->cros_ec, channel,
+							    &control_method);
+			if (ret == 0)
+				*val = control_method;
+		} else if (attr == hwmon_pwm_input) {
+			ret = cros_ec_hwmon_read_pwm_value(priv->cros_ec, channel, &pwm_value);
+			if (ret == 0)
+				*val = pwm_value;
+		}
 	} else if (type == hwmon_temp) {
 		if (attr == hwmon_temp_input) {
 			ret = cros_ec_hwmon_read_temp(priv->cros_ec, channel, &temp);
@@ -124,6 +181,74 @@ static int cros_ec_hwmon_read_string(struct device *dev, enum hwmon_sensor_types
 	return -EOPNOTSUPP;
 }
 
+static int cros_ec_hwmon_set_fan_pwm_val(struct cros_ec_device *cros_ec, u8 index, u8 val)
+{
+	struct ec_params_pwm_set_fan_duty_v1 req = {
+		.fan_idx = index,
+		.percent = DIV_ROUND_CLOSEST((uint32_t)val * 100, 255),
+	};
+	int ret;
+
+	ret = cros_ec_cmd(cros_ec, CROS_EC_HWMON_PWM_SET_FAN_DUTY_CMD_VERSION,
+			  EC_CMD_PWM_SET_FAN_DUTY, &req, sizeof(req), NULL, 0);
+	if (ret < 0)
+		return ret;
+	return 0;
+}
+
+static int cros_ec_hwmon_write_pwm_input(struct cros_ec_device *cros_ec, u8 index, u8 val)
+{
+	u8 control_method;
+	int ret;
+
+	ret = cros_ec_hwmon_read_pwm_enable(cros_ec, index, &control_method);
+	if (ret)
+		return ret;
+	if (control_method != 1)
+		return -EOPNOTSUPP;
+
+	return cros_ec_hwmon_set_fan_pwm_val(cros_ec, index, val);
+}
+
+static int cros_ec_hwmon_write_pwm_enable(struct cros_ec_device *cros_ec, u8 index, u8 val)
+{
+	struct ec_params_auto_fan_ctrl_v2 req = {
+		.fan_idx = index,
+		.cmd = EC_AUTO_FAN_CONTROL_CMD_SET,
+	};
+	int ret;
+
+	/* No CrOS EC supports no fan speed control */
+	if (val == 0)
+		return -EOPNOTSUPP;
+
+	req.set_auto = (val != 1) ? true : false;
+	ret = cros_ec_cmd(cros_ec, CROS_EC_HWMON_THERMAL_AUTO_FAN_CTRL_CMD_VERSION,
+			  EC_CMD_THERMAL_AUTO_FAN_CTRL, &req, sizeof(req), NULL, 0);
+	if (ret < 0)
+		return ret;
+	return 0;
+}
+
+static int cros_ec_hwmon_write(struct device *dev, enum hwmon_sensor_types type, u32 attr,
+			       int channel, long val)
+{
+	struct cros_ec_hwmon_priv *priv = dev_get_drvdata(dev);
+
+	if (type == hwmon_pwm) {
+		switch (attr) {
+		case hwmon_pwm_input:
+			return cros_ec_hwmon_write_pwm_input(priv->cros_ec, channel, val);
+		case hwmon_pwm_enable:
+			return cros_ec_hwmon_write_pwm_enable(priv->cros_ec, channel, val);
+		default:
+			return -EOPNOTSUPP;
+		}
+	}
+
+	return -EOPNOTSUPP;
+}
+
 static umode_t cros_ec_hwmon_is_visible(const void *data, enum hwmon_sensor_types type,
 					u32 attr, int channel)
 {
@@ -132,6 +257,9 @@ static umode_t cros_ec_hwmon_is_visible(const void *data, enum hwmon_sensor_type
 	if (type == hwmon_fan) {
 		if (priv->usable_fans & BIT(channel))
 			return 0444;
+	} else if (type == hwmon_pwm) {
+		if (priv->fan_control_supported && priv->usable_fans & BIT(channel))
+			return 0644;
 	} else if (type == hwmon_temp) {
 		if (priv->temp_sensor_names[channel])
 			return 0444;
@@ -147,6 +275,11 @@ static const struct hwmon_channel_info * const cros_ec_hwmon_info[] = {
 			   HWMON_F_INPUT | HWMON_F_FAULT,
 			   HWMON_F_INPUT | HWMON_F_FAULT,
 			   HWMON_F_INPUT | HWMON_F_FAULT),
+	HWMON_CHANNEL_INFO(pwm,
+			   HWMON_PWM_INPUT | HWMON_PWM_ENABLE,
+			   HWMON_PWM_INPUT | HWMON_PWM_ENABLE,
+			   HWMON_PWM_INPUT | HWMON_PWM_ENABLE,
+			   HWMON_PWM_INPUT | HWMON_PWM_ENABLE),
 	HWMON_CHANNEL_INFO(temp,
 			   HWMON_T_INPUT | HWMON_T_FAULT | HWMON_T_LABEL,
 			   HWMON_T_INPUT | HWMON_T_FAULT | HWMON_T_LABEL,
@@ -178,6 +311,7 @@ static const struct hwmon_channel_info * const cros_ec_hwmon_info[] = {
 static const struct hwmon_ops cros_ec_hwmon_ops = {
 	.read = cros_ec_hwmon_read,
 	.read_string = cros_ec_hwmon_read_string,
+	.write = cros_ec_hwmon_write,
 	.is_visible = cros_ec_hwmon_is_visible,
 };
 
@@ -233,6 +367,25 @@ static void cros_ec_hwmon_probe_fans(struct cros_ec_hwmon_priv *priv)
 	}
 }
 
+static inline bool is_cros_ec_cmd_available(struct cros_ec_device *cros_ec,
+					    u16 cmd, u8 version)
+{
+	int ret;
+
+	ret = cros_ec_get_cmd_versions(cros_ec, cmd);
+	return ret >= 0 && (ret & EC_VER_MASK(version));
+}
+
+static bool cros_ec_hwmon_probe_fan_control_supported(struct cros_ec_device *cros_ec)
+{
+	return is_cros_ec_cmd_available(cros_ec, EC_CMD_PWM_GET_FAN_DUTY,
+					CROS_EC_HWMON_PWM_GET_FAN_DUTY_CMD_VERSION) &&
+	       is_cros_ec_cmd_available(cros_ec, EC_CMD_PWM_SET_FAN_DUTY,
+					CROS_EC_HWMON_PWM_SET_FAN_DUTY_CMD_VERSION) &&
+	       is_cros_ec_cmd_available(cros_ec, EC_CMD_THERMAL_AUTO_FAN_CTRL,
+					CROS_EC_HWMON_THERMAL_AUTO_FAN_CTRL_CMD_VERSION);
+}
+
 static int cros_ec_hwmon_probe(struct platform_device *pdev)
 {
 	struct device *dev = &pdev->dev;
@@ -259,13 +412,88 @@ static int cros_ec_hwmon_probe(struct platform_device *pdev)
 
 	cros_ec_hwmon_probe_temp_sensors(dev, priv, thermal_version);
 	cros_ec_hwmon_probe_fans(priv);
+	priv->fan_control_supported = cros_ec_hwmon_probe_fan_control_supported(priv->cros_ec);
 
 	hwmon_dev = devm_hwmon_device_register_with_info(dev, "cros_ec", priv,
 							 &cros_ec_hwmon_chip_info, NULL);
+	platform_set_drvdata(pdev, priv);
 
 	return PTR_ERR_OR_ZERO(hwmon_dev);
 }
 
+static int cros_ec_hwmon_suspend(struct platform_device *pdev, pm_message_t state)
+{
+	struct cros_ec_hwmon_priv *priv = platform_get_drvdata(pdev);
+	u8 control_method;
+	size_t i;
+	int ret;
+
+	if (!priv->fan_control_supported)
+		return 0;
+
+	/* EC sets fan control to auto after suspended, store settings before suspending. */
+	for (i = 0; i < EC_FAN_SPEED_ENTRIES; i++) {
+		if (!(priv->usable_fans & BIT(i)))
+			continue;
+
+		ret = cros_ec_hwmon_read_pwm_enable(priv->cros_ec, i, &control_method);
+		if (ret) {
+			dev_warn(&pdev->dev, "failed to get mode setting for fan %zu: %d\n", i,
+				 ret);
+			continue;
+		}
+
+		if (control_method != 1) {
+			priv->manual_fans &= ~BIT(i);
+			continue;
+		} else {
+			priv->manual_fans |= BIT(i);
+		}
+
+		ret = cros_ec_hwmon_read_pwm_value(priv->cros_ec, i, &priv->manual_fan_pwm[i]);
+		/*
+		 * If storing the value failed, invalidate the stored mode value by setting it
+		 * to auto control. EC will automatically switch to auto mode for that fan after
+		 * suspended.
+		 */
+		if (ret) {
+			dev_warn(&pdev->dev, "failed to get PWM setting for fan %zu: %pe\n", i,
+				 ERR_PTR(ret));
+			priv->manual_fans &= ~BIT(i);
+			continue;
+		}
+	}
+
+	return 0;
+}
+
+static int cros_ec_hwmon_resume(struct platform_device *pdev)
+{
+	const struct cros_ec_hwmon_priv *priv = platform_get_drvdata(pdev);
+	size_t i;
+	int ret;
+
+	if (!priv->fan_control_supported)
+		return 0;
+
+	/* EC sets fan control to auto after suspend, restore to settings before suspend. */
+	for (i = 0; i < EC_FAN_SPEED_ENTRIES; i++) {
+		if (!(priv->manual_fans & BIT(i)))
+			continue;
+
+		/*
+		 * Setting fan PWM value to EC will change the mode to manual for that fan in EC as
+		 * well, so we do not need to issue a separate fan mode to manual call.
+		 */
+		ret = cros_ec_hwmon_set_fan_pwm_val(priv->cros_ec, i, priv->manual_fan_pwm[i]);
+		if (ret)
+			dev_warn(&pdev->dev, "failed to restore settings for fan %zu: %pe\n", i,
+				 ERR_PTR(ret));
+	}
+
+	return 0;
+}
+
 static const struct platform_device_id cros_ec_hwmon_id[] = {
 	{ DRV_NAME, 0 },
 	{}
@@ -274,6 +502,8 @@ static const struct platform_device_id cros_ec_hwmon_id[] = {
 static struct platform_driver cros_ec_hwmon_driver = {
 	.driver.name	= DRV_NAME,
 	.probe		= cros_ec_hwmon_probe,
+	.suspend	= pm_ptr(cros_ec_hwmon_suspend),
+	.resume		= pm_ptr(cros_ec_hwmon_resume),
 	.id_table	= cros_ec_hwmon_id,
 };
 module_platform_driver(cros_ec_hwmon_driver);

-- 
2.50.0.727.gbf7dc18ff4-goog



^ permalink raw reply related	[flat|nested] 7+ messages in thread

* [PATCH v6 2/2] hwmon: (cros_ec) register fans into thermal framework cooling devices
  2025-07-18  7:08 [PATCH v6 0/2] Export fan control and register fans as cooling devices Sung-Chi Li via B4 Relay
  2025-07-18  7:08 ` [PATCH v6 1/2] hwmon: (cros_ec) add PWM control over fans Sung-Chi Li via B4 Relay
@ 2025-07-18  7:08 ` Sung-Chi Li via B4 Relay
  2025-07-18 17:38   ` Guenter Roeck
  1 sibling, 1 reply; 7+ messages in thread
From: Sung-Chi Li via B4 Relay @ 2025-07-18  7:08 UTC (permalink / raw)
  To: Benson Leung, Guenter Roeck, Thomas Weißschuh, Jean Delvare,
	Guenter Roeck, Jonathan Corbet, Thomas Weißschuh
  Cc: chrome-platform, linux-kernel, linux-hwmon, linux-doc,
	Sung-Chi Li, Sung-Chi Li

From: Sung-Chi Li <lschyi@chromium.org>

Register fans connected under EC as thermal cooling devices as well, so
these fans can then work with the thermal framework.

During the driver probing phase, we will also try to register each fan
as a thermal cooling device based on previous probe result (whether the
there are fans connected on that channel, and whether EC supports fan
control). The basic get max state, get current state, and set current
state methods are then implemented as well.

Signed-off-by: Sung-Chi Li <lschyi@chromium.org>
Acked-by: Thomas Weißschuh <linux@weissschuh.net>
---
 Documentation/hwmon/cros_ec_hwmon.rst |  2 +
 drivers/hwmon/cros_ec_hwmon.c         | 83 +++++++++++++++++++++++++++++++++++
 2 files changed, 85 insertions(+)

diff --git a/Documentation/hwmon/cros_ec_hwmon.rst b/Documentation/hwmon/cros_ec_hwmon.rst
index 355557a08c9a54b4c177bafde3743e7dc02218be..6db812708325f7abb6d319af3312b4079e6923c6 100644
--- a/Documentation/hwmon/cros_ec_hwmon.rst
+++ b/Documentation/hwmon/cros_ec_hwmon.rst
@@ -27,3 +27,5 @@ Fan and temperature readings are supported. PWM fan control is also supported if
 the EC also supports setting fan PWM values and fan mode. Note that EC will
 switch fan control mode back to auto when suspended. This driver will restore
 the fan state to what they were before suspended when resumed.
+If a fan is controllable, this driver will register that fan as a cooling device
+in the thermal framework as well.
diff --git a/drivers/hwmon/cros_ec_hwmon.c b/drivers/hwmon/cros_ec_hwmon.c
index 9eddc554ddefde42f70c09689b64ad9e636a3020..48331703f2f50decf245805d735de39105e5f39f 100644
--- a/drivers/hwmon/cros_ec_hwmon.c
+++ b/drivers/hwmon/cros_ec_hwmon.c
@@ -13,6 +13,7 @@
 #include <linux/platform_device.h>
 #include <linux/platform_data/cros_ec_commands.h>
 #include <linux/platform_data/cros_ec_proto.h>
+#include <linux/thermal.h>
 #include <linux/types.h>
 #include <linux/units.h>
 
@@ -31,6 +32,11 @@ struct cros_ec_hwmon_priv {
 	u8 manual_fan_pwm[EC_FAN_SPEED_ENTRIES];
 };
 
+struct cros_ec_hwmon_cooling_priv {
+	struct cros_ec_hwmon_priv *hwmon_priv;
+	u8 index;
+};
+
 static int cros_ec_hwmon_read_fan_speed(struct cros_ec_device *cros_ec, u8 index, u16 *speed)
 {
 	int ret;
@@ -308,6 +314,42 @@ static const struct hwmon_channel_info * const cros_ec_hwmon_info[] = {
 	NULL
 };
 
+static int cros_ec_hwmon_cooling_get_max_state(struct thermal_cooling_device *cdev,
+					       unsigned long *val)
+{
+	*val = 255;
+	return 0;
+}
+
+static int cros_ec_hwmon_cooling_get_cur_state(struct thermal_cooling_device *cdev,
+					       unsigned long *val)
+{
+	const struct cros_ec_hwmon_cooling_priv *priv = cdev->devdata;
+	u8 read_val;
+	int ret;
+
+	ret = cros_ec_hwmon_read_pwm_value(priv->hwmon_priv->cros_ec, priv->index, &read_val);
+	if (ret)
+		return ret;
+
+	*val = read_val;
+	return 0;
+}
+
+static int cros_ec_hwmon_cooling_set_cur_state(struct thermal_cooling_device *cdev,
+					       unsigned long val)
+{
+	const struct cros_ec_hwmon_cooling_priv *priv = cdev->devdata;
+
+	return cros_ec_hwmon_write_pwm_input(priv->hwmon_priv->cros_ec, priv->index, val);
+}
+
+static const struct thermal_cooling_device_ops cros_ec_thermal_cooling_ops = {
+	.get_max_state = cros_ec_hwmon_cooling_get_max_state,
+	.get_cur_state = cros_ec_hwmon_cooling_get_cur_state,
+	.set_cur_state = cros_ec_hwmon_cooling_set_cur_state,
+};
+
 static const struct hwmon_ops cros_ec_hwmon_ops = {
 	.read = cros_ec_hwmon_read,
 	.read_string = cros_ec_hwmon_read_string,
@@ -386,6 +428,46 @@ static bool cros_ec_hwmon_probe_fan_control_supported(struct cros_ec_device *cro
 					CROS_EC_HWMON_THERMAL_AUTO_FAN_CTRL_CMD_VERSION);
 }
 
+static void cros_ec_hwmon_register_fan_cooling_devices(struct device *dev,
+						       struct cros_ec_hwmon_priv *priv)
+{
+	struct cros_ec_hwmon_cooling_priv *cpriv;
+	struct thermal_cooling_device *cdev;
+	const char *type;
+	size_t i;
+
+	if (!IS_ENABLED(CONFIG_THERMAL))
+		return;
+
+	if (!priv->fan_control_supported)
+		return;
+
+	for (i = 0; i < EC_FAN_SPEED_ENTRIES; i++) {
+		if (!(priv->usable_fans & BIT(i)))
+			continue;
+
+		cpriv = devm_kzalloc(dev, sizeof(*cpriv), GFP_KERNEL);
+		if (!cpriv)
+			continue;
+
+		type = devm_kasprintf(dev, GFP_KERNEL, "%s-fan%zu", dev_name(dev), i);
+		if (!type) {
+			dev_warn(dev, "no memory to compose cooling device type for fan %zu\n", i);
+			continue;
+		}
+
+		cpriv->hwmon_priv = priv;
+		cpriv->index = i;
+		cdev = devm_thermal_of_cooling_device_register(dev, NULL, type, cpriv,
+							       &cros_ec_thermal_cooling_ops);
+		if (IS_ERR(cdev)) {
+			dev_warn(dev, "failed to register fan %zu as a cooling device: %pe\n", i,
+				 cdev);
+			continue;
+		}
+	}
+}
+
 static int cros_ec_hwmon_probe(struct platform_device *pdev)
 {
 	struct device *dev = &pdev->dev;
@@ -413,6 +495,7 @@ static int cros_ec_hwmon_probe(struct platform_device *pdev)
 	cros_ec_hwmon_probe_temp_sensors(dev, priv, thermal_version);
 	cros_ec_hwmon_probe_fans(priv);
 	priv->fan_control_supported = cros_ec_hwmon_probe_fan_control_supported(priv->cros_ec);
+	cros_ec_hwmon_register_fan_cooling_devices(dev, priv);
 
 	hwmon_dev = devm_hwmon_device_register_with_info(dev, "cros_ec", priv,
 							 &cros_ec_hwmon_chip_info, NULL);

-- 
2.50.0.727.gbf7dc18ff4-goog



^ permalink raw reply related	[flat|nested] 7+ messages in thread

* Re: [PATCH v6 1/2] hwmon: (cros_ec) add PWM control over fans
  2025-07-18  7:08 ` [PATCH v6 1/2] hwmon: (cros_ec) add PWM control over fans Sung-Chi Li via B4 Relay
@ 2025-07-18 17:37   ` Guenter Roeck
  2025-07-19  4:45   ` Guenter Roeck
  1 sibling, 0 replies; 7+ messages in thread
From: Guenter Roeck @ 2025-07-18 17:37 UTC (permalink / raw)
  To: Sung-Chi Li
  Cc: Benson Leung, Guenter Roeck, Thomas Weißschuh, Jean Delvare,
	Jonathan Corbet, Thomas Weißschuh, chrome-platform,
	linux-kernel, linux-hwmon, linux-doc, Sung-Chi Li

On Fri, Jul 18, 2025 at 03:08:29PM +0800, Sung-Chi Li wrote:
> From: Sung-Chi Li <lschyi@chromium.org>
> 
> Newer EC firmware supports controlling fans through host commands, so
> adding corresponding implementations for controlling these fans in the
> driver for other kernel services and userspace to control them.
> 
> The driver will first probe the supported host command versions (get and
> set of fan PWM values, get and set of fan control mode) to see if the
> connected EC fulfills the requirements of controlling the fan, then
> exposes corresponding sysfs nodes for userspace to control the fan with
> corresponding read and write implementations.
> As EC will automatically change the fan mode to auto when the device is
> suspended, the power management hooks are added as well to keep the fan
> control mode and fan PWM value consistent during suspend and resume. As
> we need to access the hwmon device in the power management hook, update
> the driver by storing the hwmon device in the driver data as well.
> 
> Signed-off-by: Sung-Chi Li <lschyi@chromium.org>
> Acked-by: Thomas Weißschuh <linux@weissschuh.net>

Applied.

Thanks,
Guenter

^ permalink raw reply	[flat|nested] 7+ messages in thread

* Re: [PATCH v6 2/2] hwmon: (cros_ec) register fans into thermal framework cooling devices
  2025-07-18  7:08 ` [PATCH v6 2/2] hwmon: (cros_ec) register fans into thermal framework cooling devices Sung-Chi Li via B4 Relay
@ 2025-07-18 17:38   ` Guenter Roeck
  0 siblings, 0 replies; 7+ messages in thread
From: Guenter Roeck @ 2025-07-18 17:38 UTC (permalink / raw)
  To: Sung-Chi Li
  Cc: Benson Leung, Guenter Roeck, Thomas Weißschuh, Jean Delvare,
	Jonathan Corbet, Thomas Weißschuh, chrome-platform,
	linux-kernel, linux-hwmon, linux-doc, Sung-Chi Li

On Fri, Jul 18, 2025 at 03:08:30PM +0800, Sung-Chi Li wrote:
> From: Sung-Chi Li <lschyi@chromium.org>
> 
> Register fans connected under EC as thermal cooling devices as well, so
> these fans can then work with the thermal framework.
> 
> During the driver probing phase, we will also try to register each fan
> as a thermal cooling device based on previous probe result (whether the
> there are fans connected on that channel, and whether EC supports fan
> control). The basic get max state, get current state, and set current
> state methods are then implemented as well.
> 
> Signed-off-by: Sung-Chi Li <lschyi@chromium.org>
> Acked-by: Thomas Weißschuh <linux@weissschuh.net>

Applied.

Thanks,
Guenter

^ permalink raw reply	[flat|nested] 7+ messages in thread

* Re: [PATCH v6 1/2] hwmon: (cros_ec) add PWM control over fans
  2025-07-18  7:08 ` [PATCH v6 1/2] hwmon: (cros_ec) add PWM control over fans Sung-Chi Li via B4 Relay
  2025-07-18 17:37   ` Guenter Roeck
@ 2025-07-19  4:45   ` Guenter Roeck
  2025-07-21  1:44     ` Sung-Chi Li
  1 sibling, 1 reply; 7+ messages in thread
From: Guenter Roeck @ 2025-07-19  4:45 UTC (permalink / raw)
  To: Sung-Chi Li
  Cc: Benson Leung, Guenter Roeck, Thomas Weißschuh, Jean Delvare,
	Jonathan Corbet, Thomas Weißschuh, chrome-platform,
	linux-kernel, linux-hwmon, linux-doc, Sung-Chi Li

On Fri, Jul 18, 2025 at 03:08:29PM +0800, Sung-Chi Li wrote:
> From: Sung-Chi Li <lschyi@chromium.org>
> 
> Newer EC firmware supports controlling fans through host commands, so
> adding corresponding implementations for controlling these fans in the
> driver for other kernel services and userspace to control them.
> 
> The driver will first probe the supported host command versions (get and
> set of fan PWM values, get and set of fan control mode) to see if the
> connected EC fulfills the requirements of controlling the fan, then
> exposes corresponding sysfs nodes for userspace to control the fan with
> corresponding read and write implementations.
> As EC will automatically change the fan mode to auto when the device is
> suspended, the power management hooks are added as well to keep the fan
> control mode and fan PWM value consistent during suspend and resume. As
> we need to access the hwmon device in the power management hook, update
> the driver by storing the hwmon device in the driver data as well.
> 
> Signed-off-by: Sung-Chi Li <lschyi@chromium.org>
> Acked-by: Thomas Weißschuh <linux@weissschuh.net>
> +
...

> +static int cros_ec_hwmon_read_pwm_enable(struct cros_ec_device *cros_ec, u8 index,
> +					 u8 *control_method)
> +{
> +	struct ec_params_auto_fan_ctrl_v2 req = {

ec_params_auto_fan_ctrl_v2 isn't declared anywhere. Looks like some patch
is missing, and I don't immediately see it. Dropping the series.

Guenter

^ permalink raw reply	[flat|nested] 7+ messages in thread

* Re: [PATCH v6 1/2] hwmon: (cros_ec) add PWM control over fans
  2025-07-19  4:45   ` Guenter Roeck
@ 2025-07-21  1:44     ` Sung-Chi Li
  0 siblings, 0 replies; 7+ messages in thread
From: Sung-Chi Li @ 2025-07-21  1:44 UTC (permalink / raw)
  To: Guenter Roeck
  Cc: Benson Leung, Guenter Roeck, Thomas Weißschuh, Jean Delvare,
	Jonathan Corbet, Thomas Weißschuh, chrome-platform,
	linux-kernel, linux-hwmon, linux-doc

On Fri, Jul 18, 2025 at 09:45:29PM -0700, Guenter Roeck wrote:
> On Fri, Jul 18, 2025 at 03:08:29PM +0800, Sung-Chi Li wrote:
> > From: Sung-Chi Li <lschyi@chromium.org>
> > 
> > Newer EC firmware supports controlling fans through host commands, so
> > adding corresponding implementations for controlling these fans in the
> > driver for other kernel services and userspace to control them.
> > 
> > The driver will first probe the supported host command versions (get and
> > set of fan PWM values, get and set of fan control mode) to see if the
> > connected EC fulfills the requirements of controlling the fan, then
> > exposes corresponding sysfs nodes for userspace to control the fan with
> > corresponding read and write implementations.
> > As EC will automatically change the fan mode to auto when the device is
> > suspended, the power management hooks are added as well to keep the fan
> > control mode and fan PWM value consistent during suspend and resume. As
> > we need to access the hwmon device in the power management hook, update
> > the driver by storing the hwmon device in the driver data as well.
> > 
> > Signed-off-by: Sung-Chi Li <lschyi@chromium.org>
> > Acked-by: Thomas Weißschuh <linux@weissschuh.net>
> > +
> ...
> 
> > +static int cros_ec_hwmon_read_pwm_enable(struct cros_ec_device *cros_ec, u8 index,
> > +					 u8 *control_method)
> > +{
> > +	struct ec_params_auto_fan_ctrl_v2 req = {
> 
> ec_params_auto_fan_ctrl_v2 isn't declared anywhere. Looks like some patch
> is missing, and I don't immediately see it. Dropping the series.
> 
> Guenter

Hi, these structs are defined in the patchset v5
(https://lore.kernel.org/lkml/20250620-cros_ec_fan-v5-1-5979ea1abb31@chromium.org/).

I removed it from v6 because it was applied before. Can you help pick that
patch? Thank you.

^ permalink raw reply	[flat|nested] 7+ messages in thread

end of thread, other threads:[~2025-07-21  1:44 UTC | newest]

Thread overview: 7+ messages (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2025-07-18  7:08 [PATCH v6 0/2] Export fan control and register fans as cooling devices Sung-Chi Li via B4 Relay
2025-07-18  7:08 ` [PATCH v6 1/2] hwmon: (cros_ec) add PWM control over fans Sung-Chi Li via B4 Relay
2025-07-18 17:37   ` Guenter Roeck
2025-07-19  4:45   ` Guenter Roeck
2025-07-21  1:44     ` Sung-Chi Li
2025-07-18  7:08 ` [PATCH v6 2/2] hwmon: (cros_ec) register fans into thermal framework cooling devices Sung-Chi Li via B4 Relay
2025-07-18 17:38   ` Guenter Roeck

This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;