From mboxrd@z Thu Jan 1 00:00:00 1970 From: Guenter Roeck Subject: [PATCH] hwmon: Add tempX_emergency to sysfs ABI Date: Thu, 26 Aug 2010 08:54:45 -0700 Message-ID: <1282838085-7210-1-git-send-email-guenter.roeck@ericsson.com> Mime-Version: 1.0 Content-Type: text/plain Return-path: Sender: linux-i2c-owner-u79uwXL29TY76Z2rM5mHXA@public.gmane.org To: Jean Delvare , Andrew Morton Cc: Randy Dunlap , "Ira W. Snyder" , "Darrick J. Wong" , linux-doc-u79uwXL29TY76Z2rM5mHXA@public.gmane.org, lm-sensors-GZX6beZjE8VD60Wz+7aTrA@public.gmane.org, linux-kernel-u79uwXL29TY76Z2rM5mHXA@public.gmane.org, linux-i2c-u79uwXL29TY76Z2rM5mHXA@public.gmane.org, Guenter Roeck List-Id: linux-i2c@vger.kernel.org Signed-off-by: Guenter Roeck --- tempX_emergency will be used by max6696. It can also be used for other chips supporting three upper temperature limits. Documentation/hwmon/sysfs-interface | 6 ++++++ 1 files changed, 6 insertions(+), 0 deletions(-) diff --git a/Documentation/hwmon/sysfs-interface b/Documentation/hwmon/sysfs-interface index ff45d1f..1ceb2b9 100644 --- a/Documentation/hwmon/sysfs-interface +++ b/Documentation/hwmon/sysfs-interface @@ -310,6 +310,12 @@ temp[1-*]_crit_hyst from the critical value. RW +temp[1-*]_emergency + Temperature emergency value, typically greater than + corresponding temp_crit values. + Unit: millidegree Celsius + RW + temp[1-*]_lcrit Temperature critical min value, typically lower than corresponding temp_min values. Unit: millidegree Celsius -- 1.7.0.87.g0901d