smartctl version 5.32 Copyright (C) 2002-4 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: ST3808110AS Serial Number: 4LR0459K Firmware Version: 3.AAD Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 7 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Mon Dec 11 10:31:22 2006 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 430) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 27) minutes. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 118 079 006 Pre-fail Always - 170819894 3 Spin_Up_Time 0x0003 099 099 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 40 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 079 060 030 Pre-fail Always - 96592598 9 Power_On_Hours 0x0032 097 097 000 Old_age Always - 2710 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 74 187 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0 189 Unknown_Attribute 0x003a 100 100 000 Old_age Always - 0 190 Unknown_Attribute 0x0022 068 046 045 Old_age Always - 555614240 194 Temperature_Celsius 0x0022 032 054 000 Old_age Always - 32 (Lifetime Min/Max 0/21) 195 Hardware_ECC_Recovered 0x001a 072 046 000 Old_age Always - 144579171 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 189 000 Old_age Always - 48 200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0 202 TA_Increase_Count 0x0032 100 253 000 Old_age Always - 0 SMART Error Log Version: 1 ATA Error Count: 24 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 24 occurred at disk power-on lifetime: 2597 hours (108 days + 5 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 7f 60 45 a6 e5 Error: ICRC, ABRT 127 sectors at LBA = 0x05a64560 = 94782816 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 a0 3f 45 a6 e5 00 1d+02:54:11.924 READ DMA c8 00 08 57 2d a4 e5 00 1d+02:54:10.231 READ DMA c8 00 00 37 43 a6 e5 00 1d+02:54:14.160 READ DMA c8 00 00 27 22 b0 e5 00 1d+02:54:14.157 READ DMA c8 00 88 27 26 b0 e5 00 1d+02:54:14.116 READ DMA Error 23 occurred at disk power-on lifetime: 2227 hours (92 days + 19 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 2f 90 ff 2a e5 Error: ICRC, ABRT 47 sectors at LBA = 0x052aff90 = 86704016 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 80 3f ff 2a e5 00 01:51:05.680 READ DMA ca 00 80 bf fe 2a e5 00 01:51:05.679 WRITE DMA c8 00 80 bf fe 2a e5 00 01:51:05.709 READ DMA ca 00 80 bf fe 2a e5 00 01:51:05.709 WRITE DMA c8 00 80 bf fe 2a e5 00 01:51:05.707 READ DMA Error 22 occurred at disk power-on lifetime: 2227 hours (92 days + 19 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 1f 20 53 a2 e4 Error: ICRC, ABRT 31 sectors at LBA = 0x04a25320 = 77746976 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 80 bf 52 a2 e4 00 01:38:11.906 READ DMA ca 00 80 3f 52 a2 e4 00 01:38:11.899 WRITE DMA c8 00 80 3f 52 a2 e4 00 01:38:11.898 READ DMA ca 00 80 3f 52 a2 e4 00 01:38:11.897 WRITE DMA c8 00 80 3f 52 a2 e4 00 01:38:11.896 READ DMA Error 21 occurred at disk power-on lifetime: 2226 hours (92 days + 18 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 6f 50 45 5e e0 Error: ICRC, ABRT 111 sectors at LBA = 0x005e4550 = 6178128 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 80 3f 45 5e e0 00 00:21:37.728 READ DMA ca 00 80 bf 44 5e e0 00 00:21:37.727 WRITE DMA c8 00 80 bf 44 5e e0 00 00:21:37.726 READ DMA ca 00 80 bf 44 5e e0 00 00:21:37.725 WRITE DMA c8 00 80 bf 44 5e e0 00 00:21:37.724 READ DMA Error 20 occurred at disk power-on lifetime: 2225 hours (92 days + 17 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 d7 90 28 4a e0 Error: ICRC, ABRT 215 sectors at LBA = 0x004a2890 = 4860048 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 48 1f 28 4a e0 00 1d+06:15:04.690 READ DMA EXT c8 00 00 1f 27 4a e6 00 1d+06:15:04.686 READ DMA 25 00 68 b7 25 4a e0 00 1d+06:15:04.680 READ DMA EXT 25 00 00 b7 23 4a e0 00 1d+06:15:04.676 READ DMA EXT 25 00 48 6f 22 4a e0 00 1d+06:15:04.772 READ DMA EXT SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 2707 - # 2 Short offline Completed without error 00% 2707 - # 3 Short offline Completed without error 00% 2209 - # 4 Extended offline Completed without error 00% 1834 - # 5 Short offline Completed without error 00% 1834 - # 6 Extended offline Completed without error 00% 0 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.